31 resultados para Educational Measurement - methods
em University of Queensland eSpace - Australia
Resumo:
Study Design. Development of an automatic measurement algorithm and comparison with manual measurement methods. Objectives. To develop a new computer-based method for automatic measurement of vertebral rotation in idiopathic scoliosis from computed tomography images and to compare the automatic method with two manual measurement techniques. Summary of Background Data. Techniques have been developed for vertebral rotation measurement in idiopathic scoliosis using plain radiographs, computed tomography, or magnetic resonance images. All of these techniques require manual selection of landmark points and are therefore subject to interobserver and intraobserver error. Methods. We developed a new method for automatic measurement of vertebral rotation in idiopathic scoliosis using a symmetry ratio algorithm. The automatic method provided values comparable with Aaro and Ho's manual measurement methods for a set of 19 transverse computed tomography slices through apical vertebrae, and with Aaro's method for a set of 204 reformatted computed tomography images through vertebral endplates. Results. Confidence intervals (95%) for intraobserver and interobserver variability using manual methods were in the range 5.5 to 7.2. The mean (+/- SD) difference between automatic and manual rotation measurements for the 19 apical images was -0.5 degrees +/- 3.3 degrees for Aaro's method and 0.7 degrees +/- 3.4 degrees for Ho's method. The mean (+/- SD) difference between automatic and manual rotation measurements for the 204 endplate images was 0.25 degrees +/- 3.8 degrees. Conclusions. The symmetry ratio algorithm allows automatic measurement of vertebral rotation in idiopathic scoliosis without intraobserver or interobserver error due to landmark point selection.
Resumo:
The development of TDR for measurement of soil water content and electrical conductivity has resulted in a large shift in measurement methods for a breadth of soil and hydrological characterization efforts. TDR has also opened new possibilities for soil and plant research. Five examples show how TDR has enhanced our ability to conduct our soil- and plant-water research. (i) Oxygen is necessary for healthy root growth and plant development but quantitative evaluation of the factors controlling oxygen supply in soil depends on knowledge of the soil water content by TDR. With water content information we have modeled successfully some impact of tillage methods on oxygen supply to roots and their growth response. (ii) For field assessment of soil mechanical properties influencing crop growth, water content capability was added to two portable soil strength measuring devices; (a) A TDT (Time Domain Transmittivity)-equipped soil cone penetrometer was used to evaluate seasonal soil strengthwater content relationships. In conventional tillage systems the relationships are dynamic and achieve the more stable no-tillage relationships only relatively late in each growing season; (b) A small TDR transmission line was added to a modified sheargraph that allowed shear strength and water content to be measured simultaneously on the same sample. In addition, the conventional graphing procedure for data acquisition was converted to datalogging using strain gauges. Data acquisition rate was improved by more than a factor of three with improved data quality. (iii) How do drought tolerant plants maintain leaf water content? Non-destructive measurement of TDR water content using a flat serpentine triple wire transmission line replaces more lengthy procedures of measuring relative water content. Two challenges remain: drought-stressed leaves alter salt content, changing electrical conductivity, and drought induced changes in leaf morphology affect TDR measurements. (iv) Remote radar signals are reflected from within the first 2 cm of soil. Appropriate calibration of radar imaging for soil water content can be achieved by a parallel pair of blades separated by 8 cm, reaching 1.7 cm into soil and forming a 20 cm TDR transmission line. The correlation between apparent relative permittivity from TDR and synthetic aperture radar (SAR) backscatter coefficient was 0.57 from an airborne flyover. These five examples highlight the diversity in the application of TDR in soil and plant research.
Resumo:
Background. Prostate-specific antigen (PSA) testing for prostate cancer is controversial. Demand for PSA testing is likely to rise in the UK, Australia and other western countries. Primary care needs to develop appropriate strategies to respond to this demand. Objectives. Our aim was to compare the effectiveness of educational outreach visits (EOVs) and mailout strategies targeting PSA testing in Australian primary care. Methods. A randomized controlled trial was conducted in general practices in southern Adelaide. The main outcome measures at baseline, 6 months and 12 months post-intervention were PSA testing rates and GP knowledge in key areas relating to prostate cancer and PSA testing. Results. The interventions were able to demonstrate a change in clinical practice. In the 6 months post-intervention, median PSA testing rate in the EOV group was significantly lower than in the postal group, which in turn was significantly lower than the control group (P < 0.001). Statistically significant differences were not, however, maintained in the 6-12 month post-intervention period. The EOV group, at 6 months follow-up, had a significantly greater proportion of 'correct' responses than the control group to questions about prostate cancer treatment effectiveness (P = 0.004) and endorsement of PSA screening by professional bodies (P = 0.041). Conclusions. Primary care has a central role in PSA testing for prostate cancer. Clinical practice in this area is receptive to evidence-based interventions.
Resumo:
Free drug measurement and pharmacodymanic markers provide the opportunity for a better understanding of drug efficacy and toxicity. High-performance liquid chromatography (HPLC)-mass spectrometry (MS) is a powerful analytical technique that could facilitate the measurement of free drug and these markers. Currently, there are very few published methods for the determination of free drug concentrations by HPLC-MS. The development of atmospheric pressure ionisation sources, together with on-line microdialysis or on-line equilibrium dialysis and column switching techniques have reduced sample run times and increased assay efficiency. The availability of such methods will aid in drug development and the clinical use of certain drugs, including anti-convulsants, anti-arrhythmics, immunosuppressants, local anaesthetics, anti-fungals and protease inhibitors. The history of free drug measurement and an overview of the current HPLC-MS applications for these drugs are discussed. Immunosuppressant drugs are used as an example for the application of HPLC-MS in the measurement of drug pharmacodynamics. Potential biomarkers of immunosuppression that could be measured by HPLC-MS include purine nucleoside/nucleotides, drug-protein complexes and phosphorylated peptides. At the proteomic level, two-dimensional gel electrophoresis combined with matrix-assisted laser desorption/ionisation time-of-flight (TOF) MS is a powerful tool for identifying proteins involved in the response to inflammatory mediators. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Background: A new immunoassay for free light chain measurements has been reported to be useful for the diagnosis and monitoring of monoclonal light chain diseases and nonsecretory myeloma. We describe experience with and some potential pitfalls of the assay. Methods: The assay was assessed for precision, sample type and stability, recovery, and harmonization of results between two analyzers on which the reagents are used. Free-light-chain concentrations were measured in healthy individuals (to determine biological variation), patients with monoclonal gammopathy of undetermined significance, myeloma patients after autologous stem cell transplants, and patients with renal disease. Results: Analytical imprecision (CV) was 6-11% for kappa and A free-light-chain measurement and 16% for the calculated kappa/lambda ratio. Biological variation was generally insignificant compared with analytical variation. Despite the same reagent source, values were not completely harmonized between assay systems and may produce discordant free-light-chain ratios. In some patients with clinically stable myeloma, or post transplantation, or with monoclonal gammopathy of undetermined significance, free-light-chain concentration and ratio were within the population reference interval despite the presence of monoclonal intact immunoglobulin in serum. In other patients with monoclonal gammopathy of undetermined significance, values were abnormal although there was no clinical evidence of progression to multiple myeloma. Conclusions: The use of free-light-chain measurements alone cannot differentiate some groups of patients with monoclonal gammopathy from healthy individuals. As with the introduction of any new test, it is essential that more scientific data about use of this assay in different subject groups are available so that results can be interpreted with clinical certainty. (C) 2003 American Association for Clinical Chemistry.
Resumo:
The reliability of measurement refers to unsystematic error in observed responses. Investigations of the prevalence of random error in stated estimates of willingness to pay (WTP) are important to an understanding of why tests of validity in CV can fail. However, published reliability studies have tended to adopt empirical methods that have practical and conceptual limitations when applied to WTP responses. This contention is supported in a review of contingent valuation reliability studies that demonstrate important limitations of existing approaches to WTP reliability. It is argued that empirical assessments of the reliability of contingent values may be better dealt with by using multiple indicators to measure the latent WTP distribution. This latent variable approach is demonstrated with data obtained from a WTP study for stormwater pollution abatement. Attitude variables were employed as a way of assessing the reliability of open-ended WTP (with benchmarked payment cards) for stormwater pollution abatement. The results indicated that participants' decisions to pay were reliably measured, but not the magnitude of the WTP bids. This finding highlights the need to better discern what is actually being measured in VVTP studies, (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.
Resumo:
A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings. especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
Participation in at least 30 min of moderate intensity activity on most days is assumed to confer health benefits. This study accordingly determined whether the more vigorous household and garden tasks (sweeping, window cleaning, vacuuming and lawn mowing) are performed by middle-aged men at a moderate intensity of 3-6 metabolic equivalents (METs) in the laboratory and at home. Measured energy expenditure during self-perceived moderate-paced walking was used as a marker of exercise intensity. Energy expenditure was also predicted via indirect methods. Thirty-six males [Xmacr (SD): 40.0 (3.3) years; 179.5 (6.9) cm; 83.4 (14.0) kg] were measured for resting metabolic rate (RMR) and oxygen consumption (V.O-2) during the five activities using the Douglas bag method. Heart rate , respiratory frequency, CSA (Computer Science Applications) movement counts, Borg scale ratings of perceived exertion and Quetelet's index were also recorded as potential predictors of exercise intensity. Except for vacuuming in the laboratory, which was not significantly different from 3.0 METs (P=0.98), the MET means in the laboratory and home were all significantly greater than 3.0 (Pless than or equal to0.006). The sweeping and vacuuming MET means were significantly higher (P
Resumo:
The importance of sticky behaviour of amorphous food powders has been recognized over many decades in the food industry due to its influence on process and handling abilities and quality of the powders. This paper emphasizes the role of stickiness in the food powder industry as well as reviews the stickiness characterization techniques developed to date. This paper also attempts to correlate the stickiness behaviour of food powders to the instrumental analysis such as glass transition temperature. (C) 2004 Elsevier B.V All rights reserved.
Resumo:
Objective. To assess the measurement properties of a simple index of symptom severity in osteoarthritis (OA) of the hips and knees. Methods. Both the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the proposed new Comprehensive Osteoarthritis Test (COAT) instrument were completed weekly by 125 subjects in the context of a randomized, 12-week, 3 parallel-arm clinical trial. The reliabilities of the various scales were assessed on a weekly basis by use of Cronbach's alpha coefficients. The validity of the COAT total scale was assessed by correlation with the WOMAC total scale on a weekly basis with correlation coefficients, and in terms of the correlations between subject-level intercepts and slopes over time. The relative responsiveness of the WOMAC and COAT total scales was assessed using a multilevel (longitudinal) multivariate (WOMAC, COAT) linear model. Results. The WOMAC and COAT total scales were highly reliable (mean over weeks: WOMAC alpha = 0.98; COAT alpha = 0.97). The correlations between the WOMAC and COAT scales were very high (mean over weeks = 0.92; subject-level intercepts = 0.91, slopes = 0.88). The COAT total scale was significantly more responsive than the WOMAC total scale in the active treatment (34.8% improvement vs 26.8%; p = 0.002). Conclusion. The COAT total scale is simple to administer, reliable, valid, and responsive to treatment effects.
Resumo:
Purpose To evaluate the efficacy of a psychoeducational intervention in improving cancer-related fatigue. Patients and Methods This randomized controlled trial involved 109 women commencing adjuvant chemotherapy for stage I or II breast cancer in five chemotherapy treatment centers. Intervention group patients received an individualized fatigue education and support program delivered in the clinic and by phone over three 10- to 20-minute sessions 1 week apart. Instruments included a numeric rating scale assessing confidence with managing fatigue; 11-point numeric rating scales measuring fatigue at worst, average, and best; the Functional Assessment of Cancer Therapy-Fatigue and Piper Fatigue Scales; the Cancer Self-Efficacy Scale; the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire C30; and the Hospital Anxiety and Depression Scale. For each outcome, separate analyses of covariance of change scores between baseline (T1) and the three follow-up time points (T2, T3, and T4) were conducted, controlling for the variable's corresponding baseline value. Results Compared with the intervention group, mean difference scores between the baseline (T1) and immediate after the test (T2) assessments increased significantly more for the control group for worst and average fatigue, Functional Assessment of Cancer Therapy-Fatigue, and Piper fatigue severity and interference measures. These differences were not observed between baseline and T3 and T4 assessments. No significant differences were identified for any pre- or post-test change scores for confidence with managing fatigue, cancer self-efficacy, anxiety, depression, or quality of life. Conclusion Preparatory education and support has the potential to assist women to cope with cancer-related fatigue in the short term. However, further research is needed to identify ways to improve the potency and sustainability of psychoeducational interventions for managing cancer-related fatigue.
Resumo:
Despite current imperatives to measure client outcomes, social workers have expressed frustration with the ability of traditional forms of quantitative methods to engage with complexity, individuality and meaning. This paper argues that the inclusion of a meaning-based as opposed to a function-based approach to quality of life (QOL) may offer a quantitative means of measurement that is congruent with social-work values and practice.