75 resultados para EUV light source

em University of Queensland eSpace - Australia


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The laser diode (LD) is a unique light source that can efficiently produce all radiant energy within the narrow wavelength range used most effectively by a photosynthetic microorganism. We have investigated the use of a single type of LID for the cultivation of the well-studied anoxygenic photosynthetic bacterium, Rhodobacter capsulatus (Rb. capsulatus). An array of vertical-cavity surface-emitting lasers (VCSELs) was driven with a current of 25 mA, and delivered radiation at 860 nm with 0.4 nm linewidth. The emitted light was found to be a suitable source of radiant energy for the cultivation of Rb. capsulatus. The dependence of growth rate on incident irradiance was quantified. Despite the unusual nearly monochromatic light source used in these experiments, no significant changes in the pigment composition and in the distribution of bacteriochlorophyll between LHII and LHI-RC were detected in bacterial cells transferred from incandescent light to laser light. We were also able to show that to achieve a given growth rate in a light-limited culture, the VCSEL required only 30% of the electricity needed by an incandescent bulb, which is of great significance for the potential use of laser-devices in biotechnological applications and photobioreactor construction. (c) 2006 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 250-mum-diameter fiber of ytterbium-doped ZBLAN (fluorine combined with Zr, Ba, La, Al, and Na) has been cooled from room temperature. We coupled 1.0 W of laser light from a 1013-nm diode laser into the fiber. We measured the temperature of the fiber by using both fluorescence techniques and a microthermocouple. These microthermocouple measurements show that the cooled fiber can be used to refrigerate materials brought into contact with it. This, in conjunction with the use of a diode laser as the light source, demonstrates that practical solid-state laser coolers can be realized. (C) 2001 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Composite resin is a widely-used direct tooth coloured restorative material. Photoactivation of the polymerisation reaction can be achieved by visible blue light from a range of light sources, including halogen lamps, metal halide lamps, plasma arc lamps, and Light Emitting Diode (LED) lights. Concerns have been raised that curing lights may induce a temperature rise that could be detrimental to the vitality of the dental pulp during the act of photoactivation. The present study examined heat changes associated with standardised class V restorations on the buccal surface of extracted premolar teeth, using a curing time of 40 seconds. The independent effects of type of light source, resin shade and remaining tooth thickness were assessed using a matrix experimental design. When a conventional halogen lamp, a metal halide lamp and two different LED lights were compared, it was found that both LED lamps elicited minimal thermal changes at the level of the dental pulp, whereas the halogen lamp induced greater changes and the metal halide lamp caused the greatest thermal insult of all the light sources. These thermal changes were influenced by resin shade, with different patterns for LED versus halogen or halide sources. Thermal stress reduced as the remaining thickness of tooth structure between the pulp and the cavity floor increased. From these results, it is concluded that LED lights produce the least thermal insult during photopolymerisation of composite resins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The fluorescence of single molecules coupled to a thermal bath is studied both experimentally and theoretically. The effect of different fluctuations on the coherence properties of resonance fluorescence is considered first. Coherence is measured in an interference experiment where a single molecule is used as a light source. A standard approach based on the optical Bloch equations apparently provides quite an accurate description of the interference experiment. Systems with long correlation times (where spectra are time dependent on any timescale) are considered next. It is shown that intensity-time-frequency correlation spectroscopy, which provides both high signal-to-noise ratio and high time resolution, is very suitable for such a case. The Bloch equations are further tested in an experiment where the shape of an excitation spectral line of a single molecule is accurately measured over six orders of magnitude of the exciting laser power. Significant deviations from the predictions of the Bloch equations are found. The role of critical parameters-the correlation time of the bath, the Rabi oscillation period, and the coupling constant between the bath and the molecule-is discussed. The paper also includes a short general introduction to the methodology of single-molecule studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: A new immunoassay for free light chain measurements has been reported to be useful for the diagnosis and monitoring of monoclonal light chain diseases and nonsecretory myeloma. We describe experience with and some potential pitfalls of the assay. Methods: The assay was assessed for precision, sample type and stability, recovery, and harmonization of results between two analyzers on which the reagents are used. Free-light-chain concentrations were measured in healthy individuals (to determine biological variation), patients with monoclonal gammopathy of undetermined significance, myeloma patients after autologous stem cell transplants, and patients with renal disease. Results: Analytical imprecision (CV) was 6-11% for kappa and A free-light-chain measurement and 16% for the calculated kappa/lambda ratio. Biological variation was generally insignificant compared with analytical variation. Despite the same reagent source, values were not completely harmonized between assay systems and may produce discordant free-light-chain ratios. In some patients with clinically stable myeloma, or post transplantation, or with monoclonal gammopathy of undetermined significance, free-light-chain concentration and ratio were within the population reference interval despite the presence of monoclonal intact immunoglobulin in serum. In other patients with monoclonal gammopathy of undetermined significance, values were abnormal although there was no clinical evidence of progression to multiple myeloma. Conclusions: The use of free-light-chain measurements alone cannot differentiate some groups of patients with monoclonal gammopathy from healthy individuals. As with the introduction of any new test, it is essential that more scientific data about use of this assay in different subject groups are available so that results can be interpreted with clinical certainty. (C) 2003 American Association for Clinical Chemistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Commonly recommended plant sources of provitamin A, such as dark green leafy vegetables, are not acceptable in many population groups. The objective of this study was to identify other indigenous foods that may be effectively promoted to alleviate vitamin A deficiency (VAD) and to gather information relevant to identification, production, acquisition, and consumption of foods relevant to a food-based VAD prevention strategy in the Federated States of Micronesia. An ethnographic study on edible pandanus cultivars, involving key informant interviews and observation was carried out. Analyses revealed a great range in carotenoid content. Several orange-coloured pandanus cultivars, all highly acceptable, contained high levels of carotenoid, almost meeting daily requirements in usual consumption patterns, whereas light yellow-coloured cultivars contained low levels. Availability has decreased substantially in recent years due to increased consumption of imported foods and general neglect of indigenous foods. High-carotenoid pandanus should be promoted for general enjoyment and health benefits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bimodal NW Etendeka province is located at the continental end of the Tristan plume trace in coastal Namibia. It comprises a high-Ti (Khumib type) and three low-Ti basalt (Tafelberg, Kuidas and Esmeralda types) suites, with, at stratigraphically higher level, interstratified high-Ti latites (three units) and quartz latites (five units), and one low-Ti quartz latite. Khumib basalts are enriched in high field strength elements and light rare earth elements relative to low-Ti types and exhibit trace element affinities with Tristan da Cunha lavas. The unradiogenic Pb-206/Pb-204 ratios of Khumib basalts are distinctive, most plotting to the left of the 132 Ma Geochron, together with elevated Pb-207/Pb-204 ratios, and Sr-Nd isotopic compositions plotting in the lower Nd-143/Nd-144 part of mantle array (EM1-like). The low-Ti basalts have less coherent trace element patterns and variable, radiogenic initial Sr (similar to0.707-0.717) and Pb isotope compositions, implying crustal contamination. Four samples, however, have less radiogenic Pb and Sr that we suggest approximate their uncontaminated source. All basalt types, but particularly the low-Ti types, contain samples with trace element characteristics (e.g. Nb/Nb-*) suggesting metasediment input, considered source-related. Radiogenic isotope compositions of these samples require long-term isolation of the source in the mantle and depletions (relative to unmodified sediment) in certain elements (e.g. Cs, Pb, U), which are possibly subduction-related. A geodynamic model is proposed in which the emerging Tristan plume entrained subducted material in the Transition Zone region, and further entrained asthenosphere during plume head expansion. Mixing calculations suggest that the main features of the Etendeka basalt types can be explained without sub-continental lithospheric mantle input. Crustal contamination is evident in most low-Ti basalts, but is distinct from the incorporation of a metasedimentary source component at mantle depths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research in individualist cultures has shown that group members are more likely to agree with criticisms of their group when the criticisms are made by another ingroup member as opposed to an outgroup member (the intergroup sensitivity effect). However, evaluations of ingroup critics are often harsher when they take their comments to an outgroup audience. In light of research on facework and tolerance for dissent, it seems important to test whether these effects are generalizable to a collectivist culture. Indonesian Muslims (N = 191) received a criticism of their religion stemming either from another Muslim or a Christian, and published in either a Muslim or a Christian newspaper. Participants agreed with the comments more when they were made by an ingroup as opposed to an outgroup member. Furthermore, consistent with previous research in Australia, the effects of audience on agreement were moderated by levels of group identification. Results are discussed in relation to theory about the functional role internal critics can play in group life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of ammonium sulphate concentration on the osmotic second virial coefficient (B-AA/M-A) for equine serum albumin (pH 5.6, 20 degrees C) have been examined by sedimentation equilibrium. After an initial steep decrease with increasing ammonium sulphate concentration, B-AA/M-A assumes an essentially concentration-independent magnitude of 8-9 ml/g. Such behaviour conforms with the statistical-mechanical prediction that a sufficient increase in ionic strength should effectively eliminate the contributions of charge interactions to B-AA/M-A but have no effect on the covolume contribution (8.4 ml/g for serum albumin). A similar situation is shown to apply to published sedimentation equilibrium data for lysozyme (pH 4.5). Although termed osmotic second virial coefficients and designated as such (B-22), the negative values obtained in published light scattering studies of both systems have been described incorrectly because of the concomitant inclusion of the protein-salt contribution to thermodynamic nonideality of the protein. Those negative values are still valid predictors of conditions conducive to crystal growth inasmuch as they do reflect situations in which there is net attraction between protein molecules. However, the source of attraction responsible for the negative virial coefficient stems from the protein-salt rather than the protein-protein contribution, which is necessarily positive. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Queensland, Australia has developed Fez, a world-leading user-interface and management system for Fedora-based institutional repositories, which bridges the gap between a repository and users. Christiaan Kortekaas, Andrew Bennett and Keith Webster will review this open source software that gives institutions the power to create a comprehensive repository solution without the hassle..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments were conducted on the nature of expert perception in the sport of squash. In the first experiment, ten expert and fifteen novice players attempted to predict the direction and force of squash strokes from either a film display (occluded at variable time periods before and after the opposing player had struck the ball) or a matched point-light display (containing only the basic kinematic features of the opponent's movement pattern). Experts outperformed the novices under both display conditions, and the same basic time windows that characterised expert and novice pick-up of information in the film task also persisted in the point-light task. This suggests that the experts' perceptual advantage is directly related to their superior pick-up of essential kinematic information. In the second experiment, the vision of six expert and six less skilled players was occluded by remotely triggered liquid-crystal spectacles at quasi-random intervals during simulated match play. Players were required to complete their current stroke even when the display was occluded and their prediction performance was assessed with respect to whether they moved to the correct half of the court to match the direction and depth of the opponent's stroke. Consistent with experiment 1, experts were found to be superior in their advance pick-up of both directional and depth information when the display was occluded during the opponent's hitting action. However, experts also remained better than chance, and clearly superior to less skilled players, in their prediction performance under conditions where occlusion occurred before any significant pre-contact preparatory movement by the opposing player was visible. This additional source of expert superiority is attributable to their superior attunement to the information contained in the situational probabilities and sequential dependences within their opponent's pattern of play.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rupture of a light cellophane diaphragm in an expansion tube has been studied by an optical method. The influence of the light diaphragm on test flow generation has long been recognised, however the diaphragm rupture mechanism is less well known. It has been previously postulated that the diaphragm ruptures around its periphery due to the dynamic pressure loading of the shock wave, with the diaphragm material at some stage being removed from the flow to allow the shock to accelerate to the measured speeds downstream. The images obtained in this series of experiments are the first to show the mechanism of diaphragm rupture and mass removal in an expansion tube. A light diaphragm was impulsively loaded via a shock wave and a series of images was recorded holographically throughout the rupture process, showing gradual destruction of the diaphragm. Features such as the diaphragm material, the interface between gases, and a reflected shock were clearly visualised. Both qualitative and quantitative aspects of the rupture dynamics were derived from the images and compared with existing one-dimensional theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been suggested that phased atomic decay in a squeezed vacuum could be detected in the fluorescence spectrum emitted from a driven two-level atom in a cavity. Recently, the existence of other very distinctive features in the fluorescence spectra arising from the nonclassical features of the squeezed vacuum has been reported. In this paper, we investigate the possibility of experimental observation of these spectra. The main obstacle to the experimentalist is ensuring an effective squeezed-vacuum-atom coupling. To overcome this problem we propose the use of a Fabry-Perot microcavity. The analysis involves a consideration of the three-dimensional nature of the electromagnetic held, and the possibility of a mismatch between the squeezed and cavity modes. The problem of squeezing bandwidths is also addressed. We show that under experimentally realistic circumstances many of the spectral anomalies predicted in free space also occur in this environment. In addition, we report large population inversions in the dressed states of the two-level atom. [S1050-2947(98)02301-4].