12 resultados para ELECTROCARDIOGRAM

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate cardiac electrical function in the Spectacled Flying Fox (bat) infested with Ixodes holocyclus. Design Prospective clinical investigation of bats treated for naturally occurring tick toxicity. Procedure ECGs were performed on bats with tick toxicity (n = 33), bats that recovered slowly (n = 5) and normally (n = 5) following treatment for tick toxicity, and on normal bats with no history of tick toxicity (n = 9). Results Bats with tick toxicity had significantly prolonged corrected QT intervals, bradycardia and rhythm disturbances which included sinus bradydysrhythmia, atrial standstill, ventricular premature complexes, and idioventricular bradydysrhythmia. Conclusions The QT prolongation observed on ECG traces of bats with tick toxicity reflected delayed ventricular repolarisation and predisposed to polymorphic ventricular tachycardia and sudden cardiac death in response to sympathetic stimulation. The inability to document ventricular tachycardia in bats shortly before death from tick toxicity may be explained by a lack of sympathetic responsiveness attributable to the unique parasympathetic innervation of the bat heart, or hypothermiainduced catecholamine receptor down-regulation. Bradycardia and rhythm disturbances may be attributable to hypothermia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In studies assessing the trends in coronary events, such as the World Health Organization (WHO) MONICA Project (multinational MONItoring of trends and determinants of CArdiovascular disease), the main emphasis has been on coronary deaths and non-fatal definite myocardial infarctions (MI). It is, however, possible that the proportion of milder MIs may be increasing because of improvements in treatment and reductions in levels of risk factors. We used the MI register data of the WHO MONICA Project to investigate several definitions for mild non-fatal MIs that would be applicable in various settings and could be used to assess trends in milder coronary events. Of 38 populations participating in the WHO MONICA MI register study, more than half registered a sufficiently wide spectrum of events that it was possible to identify subsets of milder cases. The event rates and case fatality rates of MI are clearly dependent on the spectrum of non-fatal MIs, which are included. On clinical grounds we propose that the original MONICA category ''non-fatal possible MI'' could bt:divided into two groups: ''non fatal probable MI'' and ''prolonged chest pain.'' Non-fatal probable MIs are cases, which in addition to ''typical symptoms'' have electrocardiogram (EGG) or enzyme changes suggesting cardiac ischemia, but not severe enough to fulfil the criteria for non-fatal definite MI In more than half of the MONICA Collaborating Centers, the registration of MI covers these milder events reasonably well. Proportions of non-fatal probable MIs vary less between populations than do proportions of non fatal possible MIs. Also rates of non-fatal probable MI are somewhat more highly correlated with rates of fatal events and non-fatal definite MI. These findings support the validity of the category of non-fatal probable MI. In each center the increase in event rates and the decrease in case-fatality due to the inclusion of non-fatal probable MI was lar er for women than men. For the WHO MONICA Project and other epidemiological studies the proposed category of non-fatal probable MIs can be used for assessing trends in rates of milder MI. Copyright (C) 1997 Elsevier Science Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Measurement and improvement of quality of care is a priority issue in health care. Patients hospitalized with acute coronary syndromes (ACS) constitute a high-risk population whose care, if shown to be suboptimal on the basis of available research evidence, may benefit from quality improvement interventions. Aim: To evaluate the quality of in-hospital care for patients with ACS, using explicit quality indicators. Methods: Retrospective case note review was undertaken of 397 patients admitted to three teaching hospitals in Brisbane, Queensland, Australia, between 1 October 2000 and 17 April 2001. The main out-come measures were 12 process-of-care quality indicators, calculated as either: (i) the proportion of all patients who received specific interventions or (ii) the proportion of ideal patients who received -specific interventions (i.e. patients with clear indi-cations and lacking contraindications). Results: Quality indicators with values above 80% included: (i) patient selection for thrombolysis (100%) and discharge prescription of beta-blockers (84%), (ii) antiplatelet agents (94%) and (iii) lipid-lowering agents (82%). Indicators with values between 50% and 80% included: (i) timely per-formance of electrocardiogram (ECG) on admission (61%), (ii) early coronary angiography (75%), (iii) measurement of serum lipids (71%) and (iv) discharge prescription of angiotensin-converting-enzyme (ACE) inhibitors (73%). Indicators with values <50% included: (i) timely administration of thrombolysis (35%), (ii) non-invasive risk assessment (23%) and (ii) formal in-hospital and post-hospital cardiac rehabilitation (47% and 7%, respectively). Conclusion: There were delays in performing ECG and administering thrombolysis to patients who presented to emergency departments with ACS. Improvement is warranted in use of non-invasive procedures for identifying high-risk patients who may benefit from coronary revascularization as well as use of serum lipid measurements, ACE inhibitors and cardiac rehabilitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In modern magnetic resonance imaging (MRI), patients are exposed to strong, time-varying gradient magnetic fields that may be able to induce electric fields (E-fields)/currents in tissues approaching the level of physiological significance. In this work we present theoretical investigations into induced E-fields in the thorax, and evaluate their potential influence on cardiac electric activity under the assumption that the sites of maximum E-field correspond to the myocardial stimulation threshold (an abnormal circumstance). Whole-body cylindrical and planar gradient coils were included in the model. The calculations of the induced fields are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, whole-body model. The potential for cardiac stimulation was evaluated using an electrical model of the heart. Twelve-lead electrocardiogram (ECG) signals were simulated and inspected for arrhythmias caused by the applied fields for both healthy and diseased hearts. The simulations show that the shape of the thorax and the conductive paths significantly influence induced E-fields. In healthy patients, these fields are not sufficient to elicit serious arrhythmias with the use of contemporary gradient sets. However, raising the strength and number of repeated switching episodes of gradients, as is certainly possible in local chest gradient sets, could expose patients to increased risk. For patients with cardiac disease, the risk factors are elevated. By the use of this model, the sensitivity of cardiac pathologies, such as abnormal conductive pathways, to the induced fields generated by an MRI sequence can be investigated. (C) 2003 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To improve quality of in-hospital care of patients with acute coronary syndromes using a multifaceted quality improvement program. Design. Prospective, before and after study of the effects of quality improvement interventions between October 2000 and August 2002. Quality of care of patients admitted between 1 October 2000 and 16 April 2001 (baseline) was compared with that of those admitted between 15 February 2002 and 31 August 2002 (post-intervention). Setting. Three teaching hospitals in Brisbane, Australia. Study participants. Consecutive patients (n = 1594) admitted to hospital with acute coronary syndrome [mean age 68 years (SD 14 years); 65% males]. Interventions. Clinical guidelines, reminder tools, and educational interventions; 6-monthly performance feedback; pharmacist-mediated patient education program; and facilitation of multidisciplinary review of work practices. Main outcome measures. Changes in key quality indicators relating to timing of electrocardiogram (ECG) and thrombolysis in emergency departments, serum lipid measurement, prescription of adjunctive drugs, and secondary prevention. Results. Comparing post-intervention with baseline patients, increases occurred in the proportions of eligible patients: (i) undergoing timely ECG (70% versus 61%; P = 0.04); (ii) prescribed angiotensin-converting enzyme inhibitors (70% versus 60%; P = 0.002) and lipid-lowering agents (77% versus 68%; P = 0.005); (iii) receiving cardiac counselling in hospital (57% versus 48%; P = 0.009); and (iv) referred to cardiac rehabilitation (17% versus 8%; P < 0.001). Conclusions. Multifaceted approaches can improve care processes for patients hospitalized with acute coronary syndromes. Care processes under direct clinician control changed more quickly than those reliant on complex system factors. Identifying and overcoming organizational impediments to quality improvement deserves greater attention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO(2)) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in phase delay of the PPG signals. Masimo SET (R) Rad-9 (TM) and Novametrix Oxypleth oximeters were investigated for their PPG phase characteristics on nine healthy adults. To facilitate comparison, PPG signals were acquired from fingers on the same hand in a random fashion. Results showed that mean PTT variations acquired from the Masimo oximeter (37.89 ms) were much greater than the Novametrix (5.66 ms). Documented evidence suggests that I ms variation in PTT is equivalent to I mmHg change in blood pressure. Moreover, the PTT trend derived from the Masimo oximeter can be mistaken as obstructive sleep apnoeas based on the known criteria. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG). Novametrix differed from ECG by 0.71 +/- 0.58% (p < 0.05) while Masimo differed by 4.51 +/- 3.66% (p > 0.05). Modem oximeters can be attractive for their improved SaO(2) measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: In this paper, we present a unified electrodynamic heart model that permits simulations of the body surface potentials generated by the heart in motion. The inclusion of motion in the heart model significantly improves the accuracy of the simulated body surface potentials and therefore also the 12-lead ECG. Methods: The key step is to construct an electromechanical heart model. The cardiac excitation propagation is simulated by an electrical heart model, and the resulting cardiac active forces are used to calculate the ventricular wall motion based on a mechanical model. The source-field point relative position changes during heart systole and diastole. These can be obtained, and then used to calculate body surface ECG based on the electrical heart-torso model. Results: An electromechanical biventricular heart model is constructed and a standard 12-lead ECG is simulated. Compared with a simulated ECG based on the static electrical heart model, the simulated ECG based on the dynamic heart model is more accordant with a clinically recorded ECG, especially for the ST segment and T wave of a V1-V6 lead ECG. For slight-degree myocardial ischemia ECG simulation, the ST segment and T wave changes can be observed from the simulated ECG based on a dynamic heart model, while the ST segment and T wave of simulated ECG based on a static heart model is almost unchanged when compared with a normal ECG. Conclusions: This study confirms the importance of the mechanical factor in the ECG simulation. The dynamic heart model could provide more accurate ECG simulation, especially for myocardial ischemia or infarction simulation, since the main ECG changes occur at the ST segment and T wave, which correspond with cardiac systole and diastole phases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Atrial fibrillation in the elderly is common and potentially life threatening. The classical sign of atrial fibrillation is an irregularly irregular pulse. Objective The objective of this research was to determine the accuracy of pulse palpation to detect atrial fibrillation. Methods We searched Medline, EMBASE, and the reference lists of review articles for studies that compared pulse palpation with the electrocardiogram (ECG) diagnosis of atrial fibrillation. Two reviewers independently assessed the search results to determine the eligibility of studies, extracted data, and assessed the quality of the studies. Results We identified 3 studies (2385 patients) that compared pulse palpation with ECG. The estimated sensitivity of pulse palpation ranged from 91% to 100%, while specificity ranged from 70% to 77%. Pooled sensitivity was 94% (95% confidence interval [CI], 84%-97%) and pooled specificity was 72% (95% CI 69%-75%). The pooled positive likelihood ratio was 3.39, while the pooled negative likelihood ratio was 0.10. Conclusions Pulse palpation has a high sensitivity but relatively low specificity for atrial fibrillation. It is therefore useful for ruling out atrial fibrillation. It may also be a useful screen to apply opportunistically for previously undetected atrial fibrillation. Assuming a prevalence of 3% for undetected atrial fibrillation in patients older than 65 years, and given the test's sensitivity and specificity, opportunistic pulse palpation in this age group would detect an irregular pulse in 30% of screened patients, requiring further testing with ECG. Among screened patients, 0.2% would have atrial fibrillation undetected with pulse palpation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: Polysomnography (PSG) is the current standard protocol for sleep disordered breathing (SDB) investigation in children. Presently, there are limited reliable screening tests for both central (CE) and obstructive (OE) respiratory events. This study compared three indices, derived from pulse oximetry and electrocardiogram ( ECG), with the PSG gold standard. These indices were heart rate (HR) variability, arterial blood oxygen de-saturation (SaO(2)) and pulse transit time (PTT). Methods: 15 children (12 male) from routine PSG studies were recruited (aged 3 - 14 years). The characteristics of the three indices were based on known criteria for respiratory events (RPE). Their estimation singly and in combination was evaluated with simultaneous scored PSG recordings. Results: 215 RPE and 215 tidal breathing events were analysed. For OE, the obtained sensitivity was HR (0.703), SaO(2) (0.047), PTT (0.750), considering all three indices (0) and either of the indices (0.828) while specificity was (0.891), (0.938), (0.922), (0.953) and (0.859) respectively. For CE, the sensitivity was HR (0.715), SaO(2) (0.278), PTT (0.662), considering all indices (0.040) and either of the indices (0.868) while specificity was (0.815), (0.954), (0.901), (0.960) and (0.762) accordingly. Conclusions: Preliminary findings herein suggest that the later combination of these non-invasive indices to be a promising screening method of SDB in children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brugada syndrome (BS) is a genetic disease identified by an abnormal electrocardiogram ( ECG) ( mainly abnormal ECGs associated with right bundle branch block and ST-elevation in right precordial leads). BS can lead to increased risk of sudden cardiac death. Experimental studies on human ventricular myocardium with BS have been limited due to difficulties in obtaining data. Thus, the use of computer simulation is an important alternative. Most previous BS simulations were based on animal heart cell models. However, due to species differences, the use of human heart cell models, especially a model with three-dimensional whole-heart anatomical structure, is needed. In this study, we developed a model of the human ventricular action potential (AP) based on refining the ten Tusscher et al (2004 Am. J. Physiol. Heart Circ. Physiol. 286 H1573 - 89) model to incorporate newly available experimental data of some major ionic currents of human ventricular myocytes. These modified channels include the L-type calcium current (ICaL), fast sodium current (I-Na), transient outward potassium current (I-to), rapidly and slowly delayed rectifier potassium currents (I-Kr and I-Ks) and inward rectifier potassium current (I-Ki). Transmural heterogeneity of APs for epicardial, endocardial and mid-myocardial (M) cells was simulated by varying the maximum conductance of IKs and Ito. The modified AP models were then used to simulate the effects of BS on cellular AP and body surface potentials using a three-dimensional dynamic heart - torso model. Our main findings are as follows. (1) BS has little effect on the AP of endocardial or mid-myocardial cells, but has a large impact on the AP of epicardial cells. (2) A likely region of BS with abnormal cell AP is near the right ventricular outflow track, and the resulting ST-segment elevation is located in the median precordium area. These simulation results are consistent with experimental findings reported in the literature. The model can reproduce a variety of electrophysiological behaviors and provides a good basis for understanding the genesis of abnormal ECG under the condition of BS disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding arterial distensibility has shown to be important in the pathogenesis of cardiovascular abnormalities like hypertension. It is also known that arterial pulse wave velocity (PWV) is a measure of the elasticity or stiffness of peripheral arterial blood vessels. However, it generally requires complex instrumentations to have an accurate measurement and not suited for continual monitoring. In this paper, it describes a simple and non-intrusive method to detect the cardiovascular pulse from a human wrist above the radial artery and a fingertip. The main components of this proposed method are a piezoelectric transducer and a photo-plethysmography circuitry. 5 healthy adults (4 male) with age ranging from 25 to 38 years were recruited. The timing consistency of the detected pulsations is first evaluated and compared to that obtained from a commercial electrocardiogram. Furthermore, the derived PWV is then assessed by the predicted values attained from regression equations of two previous similar studies. The results show good correlations (p < 0.05) and similarities for the former and latter respectively. The simplicity and non-invasive nature of the proposed method can be attractive for even younger or badly disturbed patients. Moreover, it can be used for prolonged monitoring for the comfort of the patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulse transit time (PTT) is a non-invasive measure, defined as time taken for the pulse pressure waves to travel from the R-wave of electrocardiogram to a selected peripheral site. Baseline PTT value is known to be influenced by physiologic variables like heart rate (HR), blood pressure (BP) and arterial compliance (AC). However, few quantitative data are available describing the factors which can influence PTT measurements in a child during breathing. The aim of this study was to investigate the effects of changes in breathing efforts on PTT baseline and fluctuations. Two different inspiratory resistive loading (IRL) devices were used to simulate loaded breathing in order to induce these effects. It is known that HR can influence the normative PTT value however the effect of HR variability (HRV) is not well-studied. Two groups of 3 healthy children ( 0.05) HR changes during all test activities. Results showed that HRV is not the sole contributor to PTT variations and suggest that changes in other physiologic parameters are also equally important. Hence, monitoring PTT measurement can be indicative of these associated changes during tidal or increased breathing efforts in healthy children.