18 resultados para ELECTIVE CAESAREAN SECTION

em University of Queensland eSpace - Australia


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This retrospective study elicits information regarding the dependence of neonatal outcome in gastroschisis upon: (1) the mode of delivery, (2) place of birth, (3) time for birth to surgery, (4) method of closure, (5) time from operation to commencement of first enteral feeds. The neonatal intensive care database from five major tertiary centres was used to identify 181 neonates with gastroschisis from 1990 to 2000. There were 8 deaths. There were no significant differences in outcome for infants delivered vaginally (102) versus Caesarean section (79), those born near the tertiary centre (133) as compared to infants born away (48), ones operated within 7 hours (125) compared with those operated after 7 hours (56), with delayed closure (30) versus primary closure (151). Neonates fed within 10 days of operation (85) had significantly lower incidence of sepsis, duration of TPN and hospital stay when compared to those fed after 10 days (96). Early commencement of feeds decreases the incidence of sepsis, duration of total parenteral nutrition (TPN) and hospital stay. Place of delivery, mode of delivery, time to surgery and type of closure do not influence neonatal outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The usefulness of umbilical artery Doppler velocimetry for the monitoring of diabetic pregnancies is controversial. The aim of the present study was to assess whether umbilical artery Doppler velocity waveform analysis can predict adverse perinatal outcomes for pregnancies complicated by pre-existing diabetes mellitus. Methods: All diabetic pregnancies (type 1 and 2) delivered at Mater Mothers' Hospital, Queensland, between 1 January 1995 and 31 December 1999 were included. All pregnant diabetic women were monitored with umbilical artery Doppler velocimetry at 28, 32, 36, and 38 weeks' gestation. Adverse perinatal outcome was defined as pregnancies with one or more of the following: small-for-gestational age, Caesarean section for non-reassuring cardiotocography, fetal acidaemia at delivery, 1-min Apgar of 3 or less, 5-min Apgar of less than 7, hypoxic ischaemic encephalopathy or perinatal death. Abnormal umbilical artery Doppler velocimetry was defined as a pulsatility index of 95th centile or higher for gestation. Results: One hundred and four pregnancies in women with pre-existing diabetes had umbilical arterial Doppler studies carried out during the study period. Twenty-three pregnancies (22.1%) had an elevated pulsatility index. If the scans were carried out within 2 weeks of delivery, 71% of pregnancies with abnormal umbilical Doppler had adverse outcomes (P < 0.01; likelihood ratio, 4.2). However, the sensitivity was 35%; specificity was 94%; positive predictive value was 80%; and negative predictive value was 68%. Only 30% of women with adverse perinatal outcomes had abnormal umbilical arterial Doppler flow. Conclusion: Umbilical artery Doppler velocimetry is not a good predictor of adverse perinatal outcomes in diabetic pregnancies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the prevalence and impact of overweight and obesity in an Australian obstetric population. Design, setting and participants: The Mater Mother's Hospital (MMH), South Brisbane, is an urban tertiary referral maternity hospital. We reviewed data for the 18401 women who were booked for antenatal care at the MMH, delivered between January 1998 and December 2002, and had a singleton pregnancy. Of those women, 14 230 had an estimated pre-pregnancy body mass index (BMI) noted in their record; 2978 women with BMI 40 kg/m(2)). Main outcome measures: Prevalence of overweight and obesity in an obstetric population; maternal, peripartum and neonatal outcomes associated with raised BMI. Results: Of the 14230 women, 6443 (45%) were of normal weight, and 4809 (34%) were overweight, obese or morbidly obese. Overweight, obese and morbidly obese women were at increased risk of adverse outcomes (figures represent adjusted odds ratio [AOR] [95% Cl]): hypertensive disorders of pregnancy (overweight 1.74 [1.45-2.15], obese 3.00 [2.40-3.74], morbidly obese 4.87 [3.27-7.24]); gestational diabetes (overweight 1.78 [1.25-2.52], obese 2.95 [2.05-4.25], morbidly obese 7.44 [4.42-12.54]); hospital admission longer than 5 days (overweight 1.36 [1.13-1.63], obese 1.49 [1.21-1.86], morbidly obese 3.18 [2.19-4.61]); and caesarean section (overweight 1.50 [1.36-1.66], obese 2.02 [1.79-2.29], morbidly obese 2.54 [1.94-3.321). Neonates born to obese and morbidly obese women had an increased risk of birth defects (obese 1.58 (1.02-2.46], morbidly obese 3.41 [1.67-6.94]); and hypoglycaemia (obese 2.57 [1.39-4.78], morbidly obese 7.14 [3.04-16.74]). Neonates born to morbidly obese women were at increased risk of admission to intensive care (2.77 [1.81-4.25]); premature delivery (< 34 weeks' gestation) (2.13 [1.13-4.01]); and jaundice (1.44 [1.09-1.89]). Conclusions: Overweight and obesity are common in pregnant women. Increasing BMI is associated with maternal and neonatal outcomes that may increase the costs of obstetric care. To assist in planning health service delivery, we believe that BMI should be routinely recorded on perinatal data collection sheets

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Working drawings showing west elevation and longitudinal section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Section taken through new bath house.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of temperature-dependent viscosity on fully developed forced convection in a duct of rectangular cross-section occupied by a fluid-saturated porous medium is investigated analytically. The Darcy flow model is applied and the viscosity-temperature relation is assumed to be an inverse-linear one. The case of uniform heat flux on the walls, i.e. the H boundary condition in the terminology of Kays and Crawford, is treated. For the case of a fluid whose viscosity decreases with temperature, it is found that the effect of the variation is to increase the Nusselt number for heated walls. Having found the velocity and the temperature distribution, the second law of thermodynamics is invoked to find the local and average entropy generation rate. Expressions for the entropy generation rate, the Bejan number, the heat transfer irreversibility, and the fluid flow irreversibility are presented in terms of the Brinkman number, the Péclet number, the viscosity variation number, the dimensionless wall heat flux, and the aspect ratio (width to height ratio). These expressions let a parametric study of the problem based on which it is observed that the entropy generated due to flow in a duct of square cross-section is more than those of rectangular counterparts while increasing the aspect ratio decreases the entropy generation rate similar to what previously reported for the clear flow case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate analytically the first and the second law characteristics of fully developed forced convection inside a porous-saturated duct of rectangular cross-section. The Darcy-Brinkman flow model is employed. Three different types of thermal boundary conditions are examined. Expressions for the Nusselt number, the Bejan number, and the dimensionless entropy generation rate are presented in terms of the system parameters. The conclusions of this analytical study will make it possible to compare, evaluate, and optimize alternative rectangular duct design options in terms of heat transfer, pressure drop, and entropy generation. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical analysis is presented to investigate fully developed (both thermally and hydrodynamically) forced convection in a duct of rectangular cross-section filled with a hyper-porous medium. The Darcy-Brinkman model for flow through porous media was adopted in the present analysis. A Fourier series type solution is applied to obtain the exact velocity and temperature distribution within the duct. The case of uniform heat flux on the walls, i.e. the H boundary condition in the terminology of Kays and Crawford [1], is treated. Values of the Nusselt number and the friction factor as a function of the aspect ratio, the Darcy number, and the viscosity ratio are reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Almost all clinical magnetic resonance imaging systems are based on circular cross-section magnets. Recent advances in elliptical cross-section RF probe and gradient coil hardware raise the question of the possibility of using elliptical cross-section magnet systems, This paper presents a methodology for calculating rapidly the magnetic fields generated by a multi-turn coil of elliptical cross-section and incorporates this in a stochastic optimization method for magnet design, An open magnet system of elliptical cross-section is designed that both reduces the claustrophobia for the patients and allows ready access by attending physicians, The magnet system is optimized for paediatric use, The coil geometry produced by the optimization method has several novel features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple design process for the design of elliptical cross-section, transverse gradient coils for use in magnetic resonance imaging (MRI) is presented. This process is based on a flexible stochastic optimization method and results in designs of high linearity and efficiency with low switching times. A design study of a shielded, transverse asymmetric elliptical coil set for use in neural imaging is presented and includes the minimization of the torques experienced by the gradient set.