45 resultados para Digital video camera
em University of Queensland eSpace - Australia
Resumo:
Time motion analysis is extensively used to assess the demands of team sports. At present there is only limited information on the reliability of measurements using this analysis tool. The aim of this study was to establish the reliability of an individual observer's time motion analysis of rugby union. Ten elite level rugby players were individually tracked in Southern Hemisphere Super 12 matches using a digital video camera. The video footage was subsequently analysed by a single researcher on two occasions one month apart. The test-retest reliability was quantified as the typical error of measurement (TEM) and rated as either good (10% TEM). The total time spent in the individual movements of walking, jogging, striding, sprinting, static exertion and being stationary had moderate to poor reliability (5.8-11.1% TEM). The frequency of individual movements had good to poor reliability (4.3-13.6% TEM), while the mean duration of individual movements had moderate reliability (7.1-9.3% TEM). For the individual observer in the present investigation, time motion analysis was shown to be moderately reliable as an evaluation tool for examining the movement patterns of players in competitive rugby. These reliability values should be considered when assessing the movement patterns of rugby players within competition.
Resumo:
Background: Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object. Methods: Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived. Results: Magnification changes as a linear function between 100 mm ( x 1) and 10 mm ( x 9.55) and then as an exponential function between 10 mm and 3 mm ( x 40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis. Conclusion: We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.
Resumo:
Traditional field sampling approaches for ecological studies of restored habitat can only cover small areas in detail, con be time consuming, and are often invasive and destructive. Spatially extensive and non-invasive remotely sensed data can make field sampling more focused and efficient. The objective of this work was to investigate the feasibility and accuracy of hand-held and airborne remotely sensed data to estimate vegetation structural parameters for an indicator plant species in a restored wetland. High spatial resolution, digital, multispectral camera images were captured from an aircraft over Sweetwater Marsh (San Diego County, California) during each growing season between 1992-1996. Field data were collected concurrently, which included plant heights, proportional ground cover and canopy architecture type, and spectral radiometer measurements. Spartina foliosa (Pacific cordgrass) is the indicator species for the restoration monitoring. A conceptual model summarizing the controls on the spectral reflectance properties of Pacific cordgrass was established. Empirical models were developed relating the stem length, density, and canopy architecture of cordgrass to normalized-difference-vegetation-index values. The most promising results were obtained from empirical estimates of total ground cover using image data that had been stratified into high, middle, and low marsh zones. As part of on-going restoration monitoring activities, this model is being used to provide maps of estimated vegetation cover.
Resumo:
Assigned 73 children, ages 7 to 14, to 1 of 3 groups (anxious, clinical control, and nonclinical control) according to their diagnostic status. Within the anxious group, children were assigned to 1 of 2 further groups on the basis of self-reported parental anxiety-either the child anxiety only group or the child + parent anxiety group. All children completed an experimental task (giving a brief talk in front of a video camera), which was the focus for a series of structured family discussions between the child and his or her parents. The aims of the study were to measure and compare across groups (a) the evaluations of children and their parents regarding the child's predicted anxiety and skill level and (b) the effect of the family discussion on children's expectations. Results indicated that, prior to the family discussion, anxious children's expectations of their future performance did not differ from those of control children. Similarly, there were no differences in children's expectations between the child anxiety group and the child + parent anxiety group. Second, compared to mothers in the child anxiety group, mothers in the child + parent anxiety group expected that their children would be more anxious and more likely to choose an avoidant problem solution (but not less skilled). Finally, the family discussion was found to produce no changes in anxious children's expectations of their future performance. The implications of these findings are discussed.
Resumo:
We examined the burst swimming performance of two Antarctic fishes, Trematomus bernacchii and T. centronotus, at five temperatures between -1 degreesC and 10 degreesC. As Antarctic fishes are considered one of the most cold specialised and stenothermal of all ectotherms, we predicted they would possess a narrow thermal performance breadth for burst swimming and a correlative decrease in performance at high temperatures. Burst swimming was assessed by videotaping swimming sequences with a 50-Hz video camera and analysing the sequences frame-by-frame to determine maximum velocity, the distance moved throughout the initial 200 ms, and the time taken to reach maximum velocity. In contrast to our prediction, we found both species possessed a wide thermal performance breadth for burst swimming. Although maximum swimming velocity for both T. bernacchii and T. centronotus was significantly highest at 6 degreesC, maximum velocity at ah other test temperatures was less than 20% lower. Thus, it appears that specialisation to a highly stable and cold environment is not necessarily associated with a narrow thermal performance breadth for burst swimming in Antarctic fish. We also examined the ability of the Antarctic fish Pagothenia borchgrevinki to acclimate their burst-swimming performance to different temperatures. We exposed P, borchgrevinki to either -1 degreesC or 4 degreesC for 4 weeks and tested their burst-swimming performance at four temperatures between -1 degreesC and 10 degreesC. Burst-swimming performance of Pagothenia borchgrevinki was unaffected by exposure to either -1 degreesC or 4 degreesC for 4 weeks. Maximum swimming velocity of both acclimation groups was thermally independent over the total temperature range of -1 degreesC to 10 degreesC. Therefore, the loss of any capacity to restructure the phenotype and an inability to thermally acclimate swimming performance appears to be associated with inhabiting a highly stable thermal environment.
Resumo:
Birth has been observed in a number of marsupial species and, in the studies to date, the newborn have crawled up to or across to the pouch. The method of birth in the quoll, a dasyurid, differs greatly from that observed in other marsupials. Births were recorded at normal speed using hand-held digital video cameras. Birth was heralded by a release of about 1 mL of watery fluid from the urogenital sinus followed by gelatinous material contained in either one or two tubes emanating from the sinus. The newborn, still encased in their placental membranes, were in the gelatinous material within a column. To exit this column, they had to grasp a hair and wriggle about 1 cm across to the pouch. In the pouch the newborn young had to compete for a teat. Although the quolls possessed 8 teats, the number of young in the pouch immediately after birth was 17, 16, 6, 16, 13 and 11 for each of the 6 quolls filmed. While birth has been described previously in another two dasyurids, the observers did not describe birth as reported here for the quoll. Nevertheless the movement of the newborn from the sinus to the pouch is so quick that this could have previously been missed. Filming birth from beneath and from the side allowed for a greater understanding of the birth process. Further studies are required to determine whether this use of a gelatinous material is part of the birth process in all dasyurids.
Resumo:
We have examined the feasibility of a telemedicine-enabled screening service for children and adolescents with diabetes in Queensland. There are approximately 1400 young people with diabetes in Queensland and only about two-thirds of them are screened in accordance with international guidelines. A regional retinal screening service was established using a non-mydriatic digital retinal camera. Seven centres volunteered to participate in the study. During a five-month pilot trial, 83 of the young people with diabetes who attend these centres underwent digital retinal screening (3.7%). Retinal images were sent via email to a paediatric ophthalmologist for review and results were returned via email. A copy of each participant's results was forwarded by mail to the referring diabetes doctor and the participant and family. The majority of the image files (96%) were rated as excellent or good. Only one participant was identified as having an abnormal result. Participants and their families expressed satisfaction with the digital retinal screening process.
Resumo:
We investigate the dynamics of the capillary thinning and break-up process for low viscosity elastic fluids such as dilute polymer solutions. Standard measurements of the evolution of the midpoint diameter of the necking fluid filament are augmented by high speed digital video images of the break up dynamics. We show that the successful operation of a capillary thinning device is governed by three important time scales (which characterize the relative importance of inertial, viscous and elastic processes), and also by two important length scales (which specify the initial sample size and the total stretch imposed on the sample). By optimizing the ranges of these geometric parameters, we are able to measure characteristic time scales for tensile stress growth as small as 1 millisecond for a number of model dilute and semi-dilute solutions of polyethylene oxide (PEO) in water and glycerol. If the final aspect ratio of the sample is too small, or the total axial stretch is too great, measurements are limited, respectively, by inertial oscillations of the liquid bridge or by the development of the well-known beads-on-a-string morphology which disrupt the formation of a uniform necking filament. By considering the magnitudes of the natural time scales associated with viscous flow, elastic stress growth and inertial oscillations it is possible to construct an operability diagram characterizing successful operation of a capillary break-up extensional rheometer. For Newtonian fluids, viscosities greater than approximately 70 mPas are required; however for dilute solutions of high molecular weight polymer, the minimum Viscosity is substantially lower due to the additional elastic stresses arising from molecular extension. For PEO of molecular weight 2.10(6) g/mol, it is possible to measure relaxation times of order 1 ms in dilute polymer solutions with zero-shear-rate viscosities on the order of 2-10 mPas.
Resumo:
As the first step in developing a protocol for the use of video-phones in community health, we carried out a feasibility study among clients with a range of health needs. Clients were equipped with a commercially available video-phone connected using the client's home telephone line. A hands-free speaker-phone and a miniature video-camera (for close-up views) were connected to the video-phone. Ten clients participated: five required wound care, two palliative care, two long-term therapy monitoring and one was a rural client. All but two were aged 75 years or more. Each client had a video-phone for an average of two to three weeks. During the six months of the study, 43 client calls were made, of which 36 (84%) were converted to video-calls. The speaker-phone was used on 24 occasions (56%) and the close-up camera on 23 occasions (53%). Both clients and nurses rated the equipment as satisfactory or better in questionnaires. None of the nurses felt that the equipment was difficult to use, including unpacking it and setting it up; only one client found it difficult. Taking into account the clients' responses, including their free-text comments, a judgement was made as to whether the video-phone had been useful to their nursing care. In seven cases it was felt to be unhelpful and in three cases it was judged helpful. Although the study sample was small, the results suggest that home telenursing is likely to be useful for rural clients in Australia, unsurprisingly, because of the distances involved.
Resumo:
Digital still cameras capable of filming short video clips are readily available, but the quality of these recordings for telemedicine has not been reported. We performed a blinded study using four commonly available digital cameras. A simulated patient with a hemiplegic gait pattern was filmed by the same videographer in an identical, brightly lit indoor setting. Six neurologists viewed the blinded video clips on their PC and comparisons were made between cameras, between video clips recorded with and without a tripod, and between video clips filmed on high- or low-quality settings. Use of a tripod had a smaller effect than expected, while images taken on a high-quality setting were strongly preferred to those taken on a low-quality setting. Although there was some variability in video quality between selected cameras, all were of sufficient quality to identify physical signs such as gait and tremor. Adequate-quality video clips of movement disorders can be produced with low-cost cameras and transmitted by email for teleneurology purposes.
Resumo:
If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.
Resumo:
Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.