8 resultados para Cyclone tracks
em University of Queensland eSpace - Australia
Resumo:
If nonprofit organisations are moving towards more market oriented ways of operating, is this changing the traditional meanings and value of commitments associated with their activities? This article discusses the findings of a research project conducted by the University of Queensland into the impact that changes in government policies are having on the community services sector, in particular disability services. The values and belief systems traditionally associated with the sector were found to be fundamentally unaltered.
Resumo:
The most recent account of Bueckeburgichnus maximus Kuhn 1958, a distinctive theropod dinosaur track from the Lower Cretaceous of Germany, is shown to be based on a referred specimen mistakenly identified as the holotype and the correct name of this taxon is deemed to be Megalosauripus maximus (Kuhn 1958). This minor revision has important consequences for nomenclature of the many European, Asian, North American and Australian dinosaur tracks attributed to megalosaurian theropods. Many of those tracks were named Megalosauripus, but that name has a confusing multiplicity of meanings and it should be restricted to the highly characteristic dinosaur track formerly identified as Bueckeburgichnus. Other tracks named "Megalosauripus”; (in its several other senses) will require new nomenclature, despite their extensive and repeated revision since 1996. It is recommended that future revision should adopt conventions of the International Code of Zoological Nomenclature. Although previous revisions expressed an intention to adhere to those conventions, these were not put into practice, with the unfortunate result of multiplying the problems that surround the nomenclature of megalosaur tracks. Introduction of the name Megalosauripus maximus (Kuhn 1958) eliminates those burgeoning problems and permits the introduction of new and objective nomenclature for presumed megalosaur tracks.
Resumo:
In spite of their wide application in comminution circuits, hydrocyclones have at least one significant disadvantage in that their operation inherently tends to return the fine denser liberated minerals to the grinding mill. This results in unnecessary overgrinding which adds to the milling cost and can adversely affect the efficiency of downstream processes. In an attempt to solve this problem, a three-product cyclone has been developed at the Julius Kruttschnitt Mineral Research Centre (JKMRC) to generate a second overflow in which the fine dense liberated minerals can be selectively concentrated for further treatment. In this paper, the design and operation of the three-product cyclone are described. The influence of the length of the second vortex finder on the performance of a 150-mm unit treating a mixture of magnetite and silica is investigated. Conventional cyclone tests were also conducted under similar conditions. Using the operational performance data of the three-product and conventional cyclones, it is shown that by optimising the length of the second vortex finder, the amount of fine dense mineral particles that reports to the three-product cyclone underflow can be reduced. In addition, the three-product cyclone can be used to generate middlings stream that may be more suitable for flash flotation than the conventional cyclone underflow, or alternatively, could be classified with a microscreen to separate the valuables from the gangue. At the same time, a fines stream having similar properties to those of the conventional overflow can be obtained. Hence, if the middlings stream was used as feed for flash flotation or microscreening, the fines stream could be used in lieu of the conventional overflow without compromising the feed requirements for the conventional flotation circuit. Some of the other potential applications of the new cyclone are described. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
A more efficient classifying cyclone (CC) for fine particle classification has been developed in recent years at the JKMRC. The novel CC, known as the JKCC, has modified profiles of the cyclone body, vortex finder, and spigot when compared to conventional hydrocyclones. The novel design increases the centrifugal force inside the cyclone and mitigates the short circuiting flow that exists in all current cyclones. It also decreases the probability of particle contamination in the place near the cyclone spigot. Consequently the cyclone efficiency is improved while the unit maintains a simple structure. An international patent has been granted for this novel cyclone design. In the first development stage-a feasibility study-a 100 mm JKCC was tested and compared with two 100 min commercial units. Very encouraging results were achieved, indicating good potential for the novel design. In the second development stage-a scale-up stage-the JKCC was scaled up to 200 mm in diameter, and its geometry was optimized through numerous tests. The performance of the JKCC was compared with a 150 nun commercial unit and exhibited sharper separation, finer separation size, and lower flow ratios. The JKCC is now being scaled up into a fill-size (480 mm) hydrocyclone in the third development stage-an industrial study. The 480 mm diameter unit will be tested in an Australian coal preparation plant, and directly compared with a commercial CC operating under the same conditions. Classifying cyclone performance for fine coal could be further improved if the unit is installed in an inclined position. The study using the 200 mm JKCC has revealed that sharpness of separation improved and the flow ratio to underflow was decreased by 43% as the cyclone inclination was varied from the vertical position (0degrees) to the horizontal position (90degrees). The separation size was not affected, although the feed rate was slightly decreased. To ensure self-emptying upon shutdown, it is recommended that the JKCC be installed at an inclination of 75-80degrees. At this angle the cyclone performance is very similar to that at a horizontal position. Similar findings have been derived from the testing of a conventional hydrocyclone. This may be of benefit to operations that require improved performance from their classifying cyclones in terms of sharpness of separation and flow ratio, while tolerating slightly reduced feed rate.