22 resultados para Custom

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes recent updates to the custom-built data-acquisition hardware operated by the Center for Hypersonics. In 2006, an ISA-to-USB bridging card was developed as part of Luke Hillyard's final-year thesis. This card allows the hardware to be connected to any recent personal computers via a (USB or RS232) serial port and it provides a number of simple text-based commands for control of the hardware. A graphical user interface program was also updated to help the experimenter manage the data acquisition functions. Sampled data is stored in text files that have been compressed with the gzip for mat. To simplify the later archiving or transport of the data, all files specific to a shot are stored in a single directory. This includes a text file for the run description, the signal configuration file and the individual sampled-data files, one for each signal that was recorded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monosaccharides provide an excellent platform to tailor molecular diversity by appending desired substituents at selected positions around the sugar scaffold. The presence of five functionalized and stereo-controlled centres on the sugar scaffolds gives the chemist plenty of scope to custom design molecules to a pharmacophore model. This review focuses on the peptidomimetic developments in this area, as well as the concept of tailoring structural and functional diversity in a library using carbohydrate scaffolds and how this can lead to increased hit rates and rapid identification of leads, which has promising prospects for drug development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper delineates the development of a prototype hybrid knowledge-based system for the optimum design of liquid retaining structures by coupling the blackboard architecture, an expert system shell VISUAL RULE STUDIO and genetic algorithm (GA). Through custom-built interactive graphical user interfaces under a user-friendly environment, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking, and member sizing optimization. For structural optimization, GA is applied to the minimum cost design of structural systems with discrete reinforced concrete sections. The design of a typical example of the liquid retaining structure is illustrated. The results demonstrate extraordinarily converging speed as near-optimal solutions are acquired after merely exploration of a small portion of the search space. This system can act as a consultant to assist novice designers in the design of liquid retaining structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a coupled knowledge-based system (KBS) for the design of liquid-retaining structures, which can handle both the symbolic knowledge processing based on engineering heuristics in the preliminary synthesis stage and the extensive numerical crunching involved in the detailed analysis stage. The prototype system is developed by employing blackboard architecture and a commercial shell VISUAL RULE STUDIO. Its present scope covers design of three types of liquid-retaining structures, namely, a rectangular shape with one compartment, a rectangular shape with two compartments and a circular shape. Through custom-built interactive graphical user interfaces, the user is directed throughout the design process, which includes preliminary design, load specification, model generation, finite element analysis, code compliance checking and member sizing optimization. It is also integrated with various relational databases that provide the system with sectional properties, moment and shear coefficients and final member details. This system can act as a consultant to assist novice designers in the design of liquid-retaining structures with increase in efficiency and optimization of design output and automated record keeping. The design of a typical example of the liquid-retaining structure is also illustrated. (C) 2003 Elsevier B.V All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the stress induced in captive estuarine crocodiles, Crocodylus porosus, by two different handling methods: manual restraint (noosing with ropes) and immobilization by electro-stunning. To stun, a short charge (approx. 6 s) at 110 V was delivered to the back of the necks of C. porosus using a custom-built device, which immobilized the animals for 5-10 min. Immobilized and restrained animals were measured and sexed, and the condition of the skin assessed. Blood samples were taken from some animals immediately after restraint or immobilization. Other animals were returned to their pens to recover for periods of 30 min, 1, 4, 12, 24 or 48 hours after which they were stunned and blood samples taken. Individual animals (mean body length 1.96 m, N=99) were bled only once. Haematocrit and haemoglobin concentrations were measured and plasma samples were analysed for corticosterone, glucose and lactate levels. Following restraint, there were significant increases in haematocrit, haemoglobin, glucose, lactate and corticosterone concentrations in C. porosus. For restrained animals, recovery to baseline levels occurred after approximately 8 hours. The stress response of stunned animals was significantly reduced compared to manually captured and restrained crocodiles. Both groups showed a significant increase in haematocrit, haemoglobin concentration and lactate levels, however the magnitude of change was significantly reduced, and recovery was faster in stunned animals. No increase in either glucose or corticosterone levels occurred with immobilisation. The results imply that immobilization by electro-stunning is much less stressful. (C) 2003 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of new experimental techniques for the determination of phase equilibria in complex slag systems, chemical thermodynamic, and viscosity models is reported. The new experimental data, and new thermodynamic and viscosity models, have been combined in a custom-designed computer software package to produce limiting operability diagrams for slag systems. These diagrams are used to describe phase equilibria and physicochemical properties in complex slag systems. The approach is illustrated with calculations on the system FeO-Fe2O3-CaO-SiO-Al2O3 at metallic iron saturation, slags produced in coal slagging gasifiers, and in the reprocessing of nonferrous smelting slags. This article was presented at the Mills Symposium Molten Metals, Slags and Glasses-Characterisation of Properties and Phenomena held in London in August 2000.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to compare onset of deep and superficial cervical flexor muscle activity during rapid, unilateral arm movements between ten patients with chronic neck pain and 12 control subjects. Deep cervical flexor (DCF) electromyographic activity (EMG) was recorded with custom electrodes inserted via the nose and fixed by suction to the posterior mucosa of the oropharynx. Surface electrodes were placed over the sternocleidomastoid (SCM) and anterior scalene (AS) muscles. While standing, subjects flexed and extended the right arm in response to a visual stimulus. For the control group, activation of DCF, SCM and AS muscles occurred less than 50 ms after the onset of deltoid activity, which is consistent with feedforward control of the neck during arm flexion and extension. When subjects with a history of neck pain flexed the arm, the onsets of DCF and contralateral SCM and AS muscles were significantly delayed (p<0.05). It is concluded that the delay in neck muscle activity associated with movement of the arm in patients with neck pain indicates a significant deficit in the automatic feedforward control of the cervical spine. As the deep cervical muscles are fundamentally important for support of the cervical lordosis and the cervical joints, change in the feedforward response may leave the cervical spine vulnerable to reactive forces from arm movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design. Cross-sectional study. Objective. The present study compared activity of deep and superficial cervical flexor muscles and craniocervical flexion range of motion during a test of craniocervical flexion between 10 patients with chronic neck pain and 10 controls. Summary of Background Data. Individuals with chronic neck pain exhibit reduced performance on a test of craniocervical flexion, and training of this maneuver is effective in management of neck complaints. Although this test is hypothesized to reflect dysfunction of the deep cervical flexor muscles, this has not been tested. Methods. Deep cervical flexor electromyographic activity was recorded with custom electrodes inserted via the nose and fixed by suction to the posterior mucosa of the oropharynx. Surface electrodes were placed over the superficial neck muscles ( sternocleidomastoid and anterior scalene). Root mean square electromyographic amplitude and craniocervical flexion range of motion was measured during five incremental levels of craniocervical flexion in supine. Results. There was a strong linear relation between the electromyographic amplitude of the deep cervical flexor muscles and the incremental stages of the craniocervical flexion test for control and individuals with neck pain ( P = 0.002). However, the amplitude of deep cervical flexor electromyographic activity was less for the group with neck pain than controls, and this difference was significant for the higher increments of the task ( P < 0.05). Although not significant, there was a strong trend for greater sternocleidomastoid and anterior scalene electromyographic activity for the group with neck pain. Conclusions. These data confirm that reduced performance of the craniocervical flexion test is associated with dysfunction of the deep cervical flexor muscles and support the validity of this test for patients with neck pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The advantages of antennas that can resemble the shape of the body to which they are attached are obvious. However, electromagnetic modeling of such unusually shaped antennas can be difficult. In this paper, the commercially available software SolidWorks(TM) is used for accurately drawing complex shapes in conjunction with the electromagnetic software FEKO(TM) to model the EM behavior of conformal antennas. The application of SolidWorks and custom-written software allows all the required information that forms the analyzed structure to be automatically inserted into FEKO, and gives the user complete control over the antenna being modeled. This approach is illustrated by a number of simulation examples of single, wideband, multi-band planar and curved patch antennas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have designed and tested an Internet-based video-phone suitable for use in the homes of families in need of paediatric palliative care services. The equipment uses an ordinary telephone line and includes a PC, Web camera and modem housed in a custom-made box. In initial field testing, six clinical consultations were conducted in a one-month trial of the videophone with a family in receipt of palliative care services who were living in the outer suburbs of Brisbane. Problems with variability in call quality-namely audio and video freezing, and audio break-up-prompted further laboratory testing. We completed a programme of over 250 test calls. Fixing modem connection parameters to use the V.34 modulation protocol at a set bandwidth of 24 kbit/s improved connection stability and the reliability of the video-phone. In subsequent field testing 47 of 50 calls (94%) connected without problems. The freezes that did occur were brief (with greatly reduced packet loss) and had little effect on the ability to communicate, unlike the problems arising in the home testing. The low-bandwidth Internet-based video-phone we have developed provides a feasible means of doing telemedicine in the home.