Resumo:
Survival of bone marrow transplant recipients requiting mechanical ventilation is poor but improving. This study reports a retrospective audit of all haematopoietic stem cell transplant (HSCT) recipients requiring mechanical ventilation at an Australian institution over a period spanning 11 years from 1988 to 1998. Recipients of autologous transplants are significantly less likely to require mechanical ventilation than recipients of allogeneic transplants. Of 50 patients requiring mechanical ventilation, 28% survived to discharge from the intensive care unit, 20% to 30 days post-ventilation, 18% to discharge from hospital and 12% to six months post-ventilation. Risk factors for mortality in the HSCT recipient requiting mechanical ventilation include renal, hepatic and cardiovascular insufficiency and greater severity of illness. Mechanical ventilation of HSCT recipients should not be regarded as futile therapy.
Resumo:
Study objectives: Respiratory muscle weakness and decreased endurance have been demonstrated following mechanical ventilation. However, its relationship to the duration of mechanical ventilation is not known. The aim of this study was to assess respiratory muscle endurance and its relationship to the duration of mechanical ventilation. Design: Prospective study. Setting: Tertiary teaching hospital ICU. Patients: Twenty subjects were recruited for the study who had received mechanical ventilation for a 48 h and had been discharged from the ICU. Measurements: FEV1 FVC, and maximal inspiratory pressure (Pimax) at functional residual capacity were recorded. The Pimax attained following resisted inspiration at 30% of the initial Pimax for 2 min was recorded, and the fatigue resistance index (FRI) [Pimax final/Pimax initial] was calculated. The duration of ICU length of stay (ICULOS), duration of mechanical ventilation (MVD), duration of weaning (WD), and Charlson comorbidities score (CCS) were also recorded. Relationships between fatigue and other parameters were analyzed using the Spearman correlations (p). Results: Subjects were admitted to the ICU for a mean duration of 7.7 days (SD, 3.7 days) and required mechanical ventilation for a mean duration of 4.6 days (SD, 2.5 days). The mean FRI was 0.88 (SD, 0.13), indicating a 12% fall in Pimax, and was negatively correlated with MVD (r = -0.65; p = 0.007). No correlations were found between the FRI and FEV1, FVC, ICULOS, WD, or CCS. Conclusions: Patients who had received mechanical ventilation for > 48 h have reduced inspiratory muscle endurance that worsens with the duration of mechanical ventilation and is present following successful weaning. These data suggest that patients needing prolonged mechanical ventilation are at risk of respiratory muscle fatigue and may benefit from respiratory muscle training.
Resumo:
This study of ventilated patients investigated current clinical practice in 476 episodes of pneumonia (48% community-acquired pneumonia, 24% hospital-acquired pneumonia, 28% ventilator-associated pneumonia) using a prospective survey in 14 intensive care units (ICUs) within Australia and New Zealand. Diagnostic methods and confidence, disease severity, microbiology and antibiotic use were assessed. All pneumonia types had similar mortality (community-acquired pneumonia 33%, hospital-acquired pneumonia 37% and ventilator-associated pneumonia 24%, P = 0.15) with no inter-hospital differences (P = 0.08-0.91). Bronchoscopy was performed in 26%, its use predicted by admission hospital (one tertiary: OR 9.98, CI 95% 5.11-19.49, P < 0.001; one regional: OR 629, CI 95% 3.24-12.20, P < 0.001), clinical signs of consolidation (OR 3.72, CI 95% 2.09-662, P < 0.001) and diagnostic confidence (OR 2.19, CI 95% 1.29-3.72, P = 0.004). Bronchoscopy did not predict outcome (P = 0.11) or appropriate antibiotic selection (P = 0.69). Inappropriate antibiotic prescription was similar for all pneumonia types (11-13%, P = 0.12) and hospitals (0-16%, P = 0.25). Blood cultures were taken in 51% of cases. For community-acquired pneumonia, 70% received a third generation cephalosporin and 65% a macrolide. Third generation cephalosporins were less frequently used for mild infections (OR 0.38, CI 95% 0.16-0.90, P = 0.03), hospital-acquired pneumonia (OR 0.40, CI 95% 0.23-0.72, P < 0.01), ventilator-associated pneumonia (OR 0.04, CI 95% 0.02-0.13, P < 0.001), suspected aspiration (OR 0.20, CI 95% 0.04-0.92, P = 0.04), in one regional (OR 0.26, CI 95% 0.07-0.97, P = 0.05) and one tertiary hospital (OR 0.14, CI 95% 0.03-0.73, P = 0.02) but were more commonly used in older patients (OR 1.02, CI 95% 1.01-1.03, P = 0.01). There is practice variability in bronchoscopy and antibiotic use for pneumonia in Australian and New Zealand ICUs without significant impact on patient outcome, as the prevalence of inappropriate antibiotic prescription is low. There are opportunities for improving microbiological diagnostic work-up for isolation of aetiological pathogens.
Resumo:
To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.
Resumo:
Functional electrical impedance tomography (EIT) measures relative impedance change that occurs in the chest during a distinct observation period and an EIT image describing regional relative impedance change is generated. Analysis of such an EIT image may be erroneous because it is based on an impedance signal that has several components. Most of the change in relative impedance in the chest is caused by air movement but other physiological events such as cardiac activity change in end expiratory level or pressure swings originating from a ventilator circuit can influence the impedance signal. We obtained EIT images and signals in spontaneously breathing healthy adults, in extremely prematurely born infants on continuous positive airway pressure and in ventilated sheep on conventional mechanical or high frequency oscillatory ventilation (HFOV). Data were analyzed in the frequency domain and results presented after band pass filtering within the frequency range of the physiological event of interest. Band pass filtering of EIT data is necessary in premature infants and on HFOV to differentiate and eliminate relative impedance changes caused by physiological events other than the one of interest.
Resumo:
The objective of this study was to determine the mortality rate and the functional outcomes of stroke patients admitted to the intensive care unit (ICU) and to identify predictors of poor outcome in this population. The records of all patients admitted to the ICU with the diagnosis of stroke between January 1994 and December 1999 were reviewed. Patients with subarachnoid haemorrhage were excluded. Data were collected on clinical and biological variables, risk factors for stroke and the presence of comorbidities. Mortality (ICU, in-hospital and three-month) and functional outcome were used as end-points. In the six-year-period, 61 patients were admitted to the ICU with either haemorrhagic or ischaemic stroke. Medical records were available for only 58 patients. There were 23 ischaemic and 35 haemorrhagic strokes. The ICU, in-hospital and three-month mortality rates were 36%, 47% and 52% respectively. There were no significant differences in the prevalence of premorbid risk factors between survivors and non-survivors. The mean Barthel score was significantly different between the independent and dependent survivors (94 +/- 6 vs 45 +/- 26, P < 0.001). A substantial number of patients with good functional outcomes had lower Rankin scores (92% vs 11%, P < 0.001). Only 46% of those who were alive at three months were functionally independent. Intensive care admission was associated with a high mortality rate and a high likelihood of dependent lifestyle after hospital discharge. Haemorrhagic stroke, fixed dilated pupil(s) and GCS < 10 during assessment were associated with increased mortality and poor functional outcome.
Resumo:
The authors investigated the effect of manual hyperinflation (MHI) with set parameters applied to patients on mechanical ventilation on hemodynamics, respiratory mechanics, and gas exchange. Sixteen critically ill patients post-septic shock, with acute lung injury, were studied. Heart rate, arterial pressure, and mean pulmonary artery pressure were recorded every minute. pulmonary artery occlusion pressure, cardiac output, arterial blood gases, and dynamic compliance (C-dyn) were recorded pre- and post-MHI. From this, systemic vascular resistance index (SVRI), cardiac index, oxygen delivery, and partial pressure of oxygen:fraction of inspired oxygen (PaO2:FiO(2)) ratio were calculated. There were significant increases in SVRI (P < 0.05) post-MHI and diastolic arterial pressure (P < 0.01)during MHI. C-dyn increased post-MHI (P < 0.01) and was sustained at 20 minutes post-MHI (P < 0.01). Subjects with an intrapulmonary cause of lung disease had a significant decrease (P = 0.02) in PaO2:FiO(2), and those with extrapulmonary causes of lung disease had a significant increase (P < 0.001) in PaO2:FiO(2) post-MHI. In critically ill patients, MHI resulted in an improvement in lung mechanics and an improvement in gas exchange in patients with lung disease due to extrapulmonary events and did not result in impairment of the cardiovascular system.
Resumo:
Patients with severe forms of Guillain-Barré syndrome (GBS) require intensive care. Specific treatment, catheterization, and devices may increase morbidity in the intensive care unit (ICU). To understand the spectrum of morbidity associated with ICU care, the authors studied 114 patients with GBS. Major morbidity occurred in 60% of patients. Complications were uncommon if ICU stay was less than 3 weeks. Respiratory complications such as pneumonia and tracheobronchitis occurred in half of the patients and were linked to mechanical ventilation. Systemic infection occurred in one-fifth of patients and was more frequent with increasing duration of ICU admission. Direct complications of treatment and invasive procedures occurred infrequently. Life-threatening complications such as gastrointestinal bleeding and pulmonary embolism were very uncommon. Pulmonary morbidity predominates in patients with severe GBS admitted to the ICU. Attention to management of mechanical ventilation and weaning is important to minimize this complication of GBS. Other causes of morbidity in a tertiary center ICU are uncommon.
Resumo:
Neuromuscular respiratory failure is not considered to be a clinical feature of chronic inflammatory demyelinating polyneuropathy (CIDP). We present 4 patients with CIDP who required respiratory assistance and mechanical ventilation. Two patients needed emergent intubation and one patient lapsed in a stupor from hypercapnia. Respiratory failure in CIDP should be considered exceptional, but more formal studies in CIDP may be needed to assess its prevalence.
Resumo:
Aim. The paper presents a study assessing the rate of adoption of a sedation scoring system and sedation guideline. Background. Clinical practice guidelines including sedation guidelines have been shown to improve patient outcomes by standardizing care. In particular sedation guidelines have been shown to be beneficial for intensive care patients by reducing the duration of ventilation. Despite the acceptance that clinical practice guidelines are beneficial, adoption rates are rarely measured. Adoption data may reveal other factors which contribute to improved outcomes. Therefore, the usefulness of the guideline may be more appropriately assessed by collecting adoption data. Method. A quasi-experimental pre-intervention and postintervention quality improvement design was used. Adoption was operationalized as documentation of sedation score every 4 hours and use of the sedation and analgesic medications suggested in the guideline. Adoption data were collected from patients' charts on a random day of the month; all patients in the intensive care unit on that day were assigned an adoption category. Sedation scoring system adoption data were collected before implementation of a sedation guideline, which was implemented using an intensive information-giving strategy, and guideline adoption data were fed back to bedside nurses. After implementation of the guideline, adoption data were collected for both the sedation scoring system and the guideline. The data were collected in the years 2002-2004. Findings. The sedation scoring system was not used extensively in the pre-intervention phase of the study; however, this improved in the postintervention phase. The findings suggest that the sedation guideline was gradually adopted following implementation in the postintervention phase of the study. Field notes taken during the implementation of the sedation scoring system and the guideline reveal widespread acceptance of both. Conclusion. Measurement of adoption is a complex process. Appropriate operationalization contributes to greater accuracy. Further investigation is warranted to establish the intensity and extent of implementation required to positively affect patient outcomes.
Resumo:
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
Resumo:
A case of aspergillus tracheobronchitis following influenza A infection in an immunocompetent 35 year old woman is described that required prolonged mechanical ventilation for airways obstruction. Treatment included liposomal amphotericin, inhaled amphotericin, gamma interferon and GM-CSF. Liposomal amphotericin therapy was associated with reversible hepatosplenomegaly. Inhaled corticosteroids with continued antifungal therapy were used for the management of severe recurrent airway obstruction. After a prolonged course of treatment she survived with fixed airways obstruction unresponsive to corticosteroids.
Resumo:
High removal rate (up to 16.6 mm(3)/s per mm) grinding of alumina and alumina-titania was investigated with respect to material removal and basic grinding parameters using a resin-bond 160 mu m grit diamond wheel at the speeds of 40 and 160 m/s, respectively. The results show that the material removal for the single-phase polycrystalline alumina and the two-phase alumina-titania composite revealed identical mechanisms of microfracture and grain dislodgement under the grinding conditioned selected. There were no distinct differences in surface roughness and morphology for both materials ground at either conventional or high speed. An increase in material removal rate did not necessarily worsen the surface toughness for the two materials at both speeds. Also the grinding forces for the two ceramics demonstrated similar characteristics at any grinding speeds and specific removal rates. Both normal and tangential grinding forces and their force ratios at the high speed were lower than those at the conventional speed, regardless of removal rates. An increase in specific removal rate caused more rapid increases in normal and tangential forces obtained at the conventional grinding speed than those at the high speed. Furthermore, it is found that the high speed grinding at all the removal rates exerted a great amount of coolant-induced normal forces in grinding zone, which were 4-6 times higher than the pure normal grinding forces. (c) 2004 Elsevier Ltd. All rights reserved.