50 resultados para Conventional hemodialysis

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbohydrate-deficient transferrin (CDT) has emerged as the best new marker for alcohol abuse. Recently plasma immunoglobulin A (IgA) reactivity with acetaldehyde (AcH)-modified proteins, or the modified proteins per se, have been proposed as a markers for high levels of alcohol consumption. In this study, we have compared CDT, IgA reactivity with AcH adducts (IgA ASR), and AcH-modified albumin with conventional markers of high alcohol intake in groups with well-defined drinking histories, The plasma activity of ALT, AST, and gamma-glutamyltransferase increased steadily with increasing alcohol consumption, CDT and AcH-modified albumin showed a similar pattern, whereas IgA ASR appeared only to be elevated after a threshold level of consumption had been reached, Neither CDT IgA ASR or AcH-modified albumin correlated strongly with any of the conventional markers or each other. This study shows that CDT, IgA ASR, AcH-modified albumin, and the conventional markers are not related, but suggests that the concurrent use of CDT and IgA ASR may lead to better identification of high alcohol intake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High removal rate (up to 16.6 mm(3)/s per mm) grinding of alumina and alumina-titania was investigated with respect to material removal and basic grinding parameters using a resin-bond 160 mu m grit diamond wheel at the speeds of 40 and 160 m/s, respectively. The results show that the material removal for the single-phase polycrystalline alumina and the two-phase alumina-titania composite revealed identical mechanisms of microfracture and grain dislodgement under the grinding conditioned selected. There were no distinct differences in surface roughness and morphology for both materials ground at either conventional or high speed. An increase in material removal rate did not necessarily worsen the surface toughness for the two materials at both speeds. Also the grinding forces for the two ceramics demonstrated similar characteristics at any grinding speeds and specific removal rates. Both normal and tangential grinding forces and their force ratios at the high speed were lower than those at the conventional speed, regardless of removal rates. An increase in specific removal rate caused more rapid increases in normal and tangential forces obtained at the conventional grinding speed than those at the high speed. Furthermore, it is found that the high speed grinding at all the removal rates exerted a great amount of coolant-induced normal forces in grinding zone, which were 4-6 times higher than the pure normal grinding forces. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Evidence for a 'putative beta(4)-adrenoceptor' originated over 20 years ago when cardiostimulant effects were observed to nonconventional partial agonists, These agonists were originally described as beta(1)- and beta(2)-adrenoceptor antagonists; however, they cause cardiostimulant effects at much higher concentrations than those required to block beta(1)- and beta(2)-adrenoceptors. Cardiostimulant effects of non-conventional partial agonists have been observed in mouse, rat, guinea-pig, cat, ferret and human heart tissues, 2. The receptor is expressed in several heart regions, including the sinoatrial node, atrium and ventricle, 3. The receptor is resistant to blockade by most antagonists that possess high affinity for beta(1)- and beta(2)- adrenoceptors, but is blocked with moderate affinity by (-)-bupranolol and CGP 20712A. 4. The receptor is pharmacologically distinct from the beta(3)-adrenoceptor. Micromolar concentrations of beta(3)-adrenoceptor agonists have no agonist or blocking activity, The receptor is also resistant to blockade by a beta(3)-adrenoceptor-selective antagonist. 5. The receptor mediates increases in cAMP levels and cAMP-dependent protein kinase (PK) A activity in cardiac tissues. Phosphodiesterase inhibition potentiates the positive chronotropic and inotropic effects of non-conventional partial agonists. 6. The receptor mediates hastening of atrial and ventricular relaxation, which is consistent with involvement of a cAMP-dependent pathway. 7. The non-conventional partial agonist (-)-[H-3]-CGP 12177A labels the cardiac putative beta(4)-adrenoceptor, Non-conventional partial agonists compete for binding with affinities that are closely similar to their agonist potencies, Catecholamines compete for binding in a stereoselective manner with a rank order of affinity of (-)-R0363 > (-)-isoprenaline > (-)-noradrenaline greater than or equal to (-)-adrenaline much greater than (-)-isoprenaline, suggesting that catecholamines can interact with the receptor. 8. The putative beta(4)-adrenoceptor appears to be coupled to the G(s)-adenylyl cyclase system, which could serve as a guide to its future cloning, Activation of the receptor may plausibly improve diastolic function but could also mediate arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simulation of competitively primed allele-specific DNA amplification has been constructed and its behavior examined, This has shown that when the ratio of the amount of homoduplex misprime product to the total amount of amplimer is low, it increases by approximately one-fourth of the mispriming frequency with each doubling of the total amount of amplimer, When the ratio is high acid reverse mispriming becomes significant, it asymptotes toward a value

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A randomized controlled trial was carried out to measure the societal costs of realtime teledermatology compared with those of conventional hospital care in New Zealand. Two rural health centres were linked to a specialist hospital via ISDN at 128 kbit/s. Over 10 months, 203 patients were referred for a specialist dermatological consultation and 26 were followed up, giving a total of 229 consultations. Fifty-four per cent were randomized to the teledermatology consultation and 46% to the conventional hospital consultation. A cost-minimization analysis was used to calculate the total costs of both types of dermatological consultation. The total cost of the 123 teledermatology consultations was NZ$34,346 and the total cost of the 106 conventional hospital consultations was NZ$30,081. The average societal cost of the teledermatology consultation was therefore NZ$279.23 compared with NZ$283.79 for the conventional hospital consultation. The marginal cost of seeing an additional patient was NZ$135 via teledermatology and NZ$284 via conventional hospital appointment. From a societal viewpoint, and assuming an equal outcome, teledermatology was a more cost-efficient use of resources than conventional hospital care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A randomized controlled trial was carried out to measure the cost-effectiveness of realtime teledermatology compared with conventional outpatient dermatology care for patients from urban and rural areas. One urban and one rural health centre were linked to a regional hospital in Northern Ireland by ISDN at 128 kbit/s. Over two years, 274 patients required a hospital outpatient dermatology referral -126 patients (46%) were randomized to a telemedicine consultation and 148 (54%) to a conventional hospital outpatient consultation. Of those seen by telemedicine, 61% were registered with an urban practice, compared with 71% of those seen conventionally. The clinical outcomes of the two types of consultation were similar - almost half the patients were managed after a single consultation with the dermatologist. The observed marginal cost per patient of the initial realtime teledermatology consultation was f52.85 for those in urban areas and f59.93 per patient for those from rural areas. The observed marginal cost of the initial conventional consultation was f47.13 for urban patients and f48.77 for rural patients. The total observed costs of teledermatology were higher than the costs of conventional care in both urban and rural areas, mainly because of the fixed equipment costs. Sensitivity analysis using a real-world scenario showed that in urban areas the average costs of the telemedicine and conventional consultations were about equal, while in rural areas the average cost of the telemedicine consultation was less than that of the conventional consultation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study reports the post-harvest qualities of conventionally versus organically grown banana fruit from nearby plantations in the Dominican Republic. The comparison involved six repeated harvests over the transition from cooler to hotter seasons. Green mature Cavendish 'Grande Naine' banana fruit were shipped to the UK. They were triggered to ripen with ethylene gas and kept under simulated retail conditions. Fruit mass, colour, firmness and flavour parameters were measured every second day over 12 d of shelf life. Sensory comparisons were conducted on four of the six harvest times. Significant differences (P<0.05) in measured quality attributes between conventionally and organically grown fruit were few and marginal. Moreover, any differences were inconsistent across harvest-times and during shelf life. Thus, organically and conventionally grown product had almost identical qualities. Sensory comparison confirmed that there was no flavour difference. This case study provides data that challenge a general perception that organic bananas have better flavour than conventional bananas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Socially responsible investment is a rapidly emerging phenomenon within the field of personal investment. However, the factors that lead investors to choose socially responsible investment products are not well understood, especially in an Australian context. This study provides a comparative examination of conventional and socially responsible investors, with the aim of identifying such factors. A total of 55 conventional investors and 54 ethical investors participated in the study by completing mailed questionnaires about their investment and general behaviour and their attitudes and beliefs. Results indicated some important differences between socially responsible and conventional investors in their beliefs of the importance of ethical issues, their investment decision-making style, and their perceptions of moral intensity. These results support the notion that socially responsible investors differ in critical ways to conventional investors, and are discussed in terms of theoretical and practical implications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunotherapy strategies aimed at increasing human Valpha24(+)Vbeta11(+) natural killer T (NKT) cell numbers are currently a major focus. To provide further information towards the goal of NKT cell-based immunotherapy, we assessed the effects of age, cancer status and prior anticancer treatment on NKT cell numbers and their expansion capacity following alpha-galactosylceramide (alpha-GalCer) stimulation. The percentage and absolute number of peripheral blood NKT cells was assessed in 40 healthy donors and 109 solid cancer patients ( colorectal ( n = 33), breast ( n = 10), melanoma ( n = 17), lung ( n = 8), renal cell carcinoma ( n = 10), other cancers ( n = 31)). Responsiveness to alpha-GalCer stimulation was also assessed in 28 of the cancer patients and 37 of the healthy donors. Natural killer T cell numbers were significantly reduced in melanoma and breast cancer patients. While NKT numbers decreased with age in healthy donors, NKT cells were decreased in these cancer subgroups despite age and sex adjustments. Prior radiation treatment was shown to contribute to the observed reduction in melanoma patients. Although cancer patient NKT cells were significantly less responsive to alpha-GalCer stimulation, they remained capable of substantial expansion. Natural killer T cells are therefore modulated by age, malignancy and prior anticancer treatment; however, cancer patient NKT cells remain capable of responding to alpha-GalCer-based immenotherapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The 'ease of use' andaccuracy in measurement of the vertical optic cup/discratio (VCDR) was compared between the conventional direct ophthalmoscope(CO) and Panoptic direct ophthalmoscope (PO) in a group of 'naive' firstyear medical students to determine which would be more suitablefor non-ophthalmologists. Methods: In this quasi-randomized method comparison study,eight students received an introductory session on ophthalmoscopythen examined 18 eyes (9 left, 9 right) with each ophthalmoscopein a private practice. The subjects were the eight students themselvesplus two other subjects. Each subject (n = 10)had one eye dilated. Students determined a VCDR and a subjectivescore of 'ease of use' on a scale of 1 (difficult)to 10 (easy). A consultant ophthalmologist (GAG) determined thebenchmark VCDR for each eye with each ophthalmoscope. Results: Of 288 eye examinations, there were 111 measure-ments of VCDR using the CO (47 undilated, 64dilated), and 140 measurements using the PO (75 undilated, 65 dilated).Differences in the students' estimated VCDR and the benchmarkwere similar for the CO and PO (P = 0.67). 'Easeof use' was scored in 288 eyes and the median score washigher in the PO overall (CO: median 8, IQR 6-9; PO median9, IQR 8-10; P < 0.0001), andwithin each session (P < 0.0001 foreach session). Conclusions: Medical students found the PO mucheasier to use, with accuracy of rating the VCDR similar to the CO. Thiscomparison would support the wider use of the PO amongst medicalstudents, general practitioners and other primary care providers.