213 resultados para Continuous phase modulation

em University of Queensland eSpace - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The technique of frequency-resolved optical gating is used to characterize the intensity and the phase of picosecond pulses after propagation through 700 m of fiber at close to the zero-dispersion wavelength. Using the frequency-resolved optical gating technique, we directly measure the severe temporal distortion resulting from the interplay between self-phase modulation and higher-order dispersion in this regime. The measured intensity and phase of the pulses after propagation are found to be in good agreement with the predictions of numerical simulations with the nonlinear Schrodinger equation. (C) 1997 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To assess the toxicity and the efficacy of preoperative radiotherapy with continuous infusion 5-fluorouracil (5-FU) for locally advanced adenocarcinoma of the rectum. Methods and Materials: Eligible patients had newly diagnosed localized adenocarcinoma of the rectum within 12 cm of the anal verge, Stage T3-4, and were suitable for curative resection. Eighty-two patients were treated with radiotherapy-50.4 Gy in 28 fractions in 5.6 weeks, given concurrently with continuous infusion 5-FU, using either 96-h/week infusion at 300 mg/m(2)/day or 7-days/week infusion at 225 mg/m(2)/day. Results: The median age was 59 years (range, 27-87), and 67% of patients were male. Pretreatment stages of the rectal cancer were T3, 89% and resectable T4, 11%, with endorectal ultrasound confirmation in 67% of patients. Grade 3 acute toxicity occurred in 5 of 82 patients (6%; 95% confidence interval [CI], 2-14%). Types of surgical resection were anterior resection, 61%; abdominoperineal resection, 35%; and other procedures, 4%. There was no operative mortality. Anastomotic leakage after low anterior resection occurred in 3 of 50 patients (6%; 95% CI, 1-17%). The pathologic complete response rate was 16% (95% CI, 9-26%). Pathologic Stages T2 or less occurred in 51%. Conclusion: Preoperative radiotherapy with continuous infusion 5-FU for locally advanced rectal cancer is a safe regimen, with a significant downstaging effect. It does not seem to lead to a significant increase in serious surgical complications. (C) 2001 Elsevier Science Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We consider the task of estimating the randomly fluctuating phase of a continuous-wave beam of light. Using the theory of quantum parameter estimation, we show that this can be done more accurately when feedback is used (adaptive phase estimation) than by any scheme not involving feedback (nonadaptive phase estimation) in which the beam is measured as it arrives at the detector. Such schemes not involving feedback include all those based on heterodyne detection or instantaneous canonical phase measurements. We also demonstrate that the superior accuracy of adaptive phase estimation is present in a regime conducive to observing it experimentally.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Four experiments investigated the attentional modulation of acoustic blinks during continuous spatial tracking tasks. Experiment 1 found blink magnitude inhibition in a visual tracking task. Experiment 2 replicated this finding and also found blink latency slowing. Experiment 3 varied the difficulty of the task and found larger blink inhibition in the easy condition. Blink latency slowing did not differ and was significant at both difficulty levels. Experiment 4 employed less difficult visual and acoustic tracking tasks at two levels of task load. Blink magnitude inhibition during the visual and facilitation during the acoustic task was significant during high load in both modality groups. Blink latency was slowed in all visual task conditions and shortened in the difficult acoustic task. These results indicate that attentional blink modulation in a continuous spatial tracking task is modality specific.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate a contradiction of quantum mechanics with local hidden variable theories for continuous quadrature phase amplitude (position and momentum) measurements. For any quantum state, this contradiction is lost for situations where the quadrature phase amplitude results are always macroscopically distinct. We show that for optical realizations of this experiment, where one uses homodyne detection techniques to perform the quadrature phase amplitude measurement, one has an amplification prior to detection, so that macroscopic fields are incident on photodiode detectors. The high efficiencies of such detectors may open a way for a loophole-free test of local hidden variable theories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider continuous observation of the nonlinear dynamics of single atom trapped in an optical cavity by a standing wave with intensity modulation. The motion of the atom changes the phase of the field which is then monitored by homodyne detection of the output field. We show that the conditional Hilbert space dynamics of this system, subject to measurement-induced perturbations, depends strongly on whether the corresponding classical dynamics is regular or chaotic. If the classical dynamics is chaotic, the distribution of conditional Hilbert space vectors corresponding to different observation records tends to be orthogonal. This is a characteristic feature of hypersensitivity to perturbation for quantum chaotic systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the conditional quantum dynamics of an electron tunneling between two quantum dots subject to a measurement using a low transparency point contact or tunnel junction. The double dot system forms a single qubit and the measurement corresponds to a continuous in time readout of the occupancy of the quantum dot. We illustrate the difference between conditional and unconditional dynamics of the qubit. The conditional dynamics is discussed in two regimes depending on the rate of tunneling through the point contact: quantum jumps, in which individual electron tunneling current events can be distinguished, and a diffusive dynamics in which individual events are ignored, and the time-averaged current is considered as a continuous diffusive variable. We include the effect of inefficient measurement and the influence of the relative phase between the two tunneling amplitudes of the double dot/point contact system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous parametric pumping of a superconducting lossy QED cavity supporting a field prepared initially as a superposition of coherent states is discussed. In contrast to classical pumping, we verify that the phase sensitivity of the parametric pumping makes the asymptotic behaviour of the cavity field state strongly dependent on the phase theta of the coherent state \ alpha > = \ alpha \e(i theta)>. Here we consider theta = pi /4, -pi /4 and we analyse the evolution of the purity of the superposition states with the help of the linear entropy and fidelity functions. We also analyse the decoherence process quantitatively through the Wigner function, for both states, verifying that the decay is slightly modified when compared to the free decoherence case: for theta = -pi /4 the process is accelerated while for theta = pi /4 it is delayed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A concept of polarization entanglement for continuous variables is introduced. For this purpose the Stokes-parameter operators and the associated Poincare sphere, which describe the quantum-optical polarization properties of light, are defined and their basic properties are reviewed. The general features of the Stokes operators are illustrated by evaluation of their means and variances for a range of simple polarization states. Some of the examples show polarization squeezing, in which the variances of one or more Stokes parameters are smaller than the coherent-state value. The main object of the paper is the application of these concepts to bright squeezed light. It is shown that a light beam formed by interference of two orthogonally polarized quadrature-squeezed beams exhibits squeezing in some of the Stokes parameters. Passage of such a primary polarization-squeezed beam through suitable optical components generates a pair of polarization-entangled light beams with the nature of a two-mode squeezed state. Implementation of these schemes using the double-fiber Sagnac interferometer provides an efficient method for the generation of bright nonclassical polarization states. The important advantage of these nonclassical polarization states for quantum communication is the possibility of experimentally determining all of the relevant conjugate variables of both squeezed and entangled fields using only linear optical elements followed by direct detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a function of temperature, the layered compound K2Na[Ag(CN)213 displays dramatic variations in luminescence thermochromism with major trend changes occurring around 80 K. In order to understand these interesting optical properties, high-resolution neutron diffraction investigations were performed on a polycrystalline sample of this material in the temperature range from 1.5 to 300 K, and previous synchrotron X-ray data of Larochelle et al. (Solid State Commun. 114, 155 (2000)) were reinterpreted. The corresponding significant structural changes were found to be continuous with an anomalous increase of the monoclinic c-lattice parameter with decreasing temperature, associated with slight reorientations of two inequivalent, approximately linear N-C-Ag-C-N units. In the whole temperature range, the crystal structure is monoclinic with the space group C2/m. Based on the structural results, the major luminescence thermochromism changes around 80 K are attributed to the dominance of a back energy transfer process from low- to high-energy excitons at high temperatures. (E) 2002 Elsevier Science (USA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous research using punctuate reaction time and counting tasks has found that the startle eyeblink reflex is sensitive to attentional demands. The present experiment explored whether startle eyeblink is also modulated during a complex continuous task and is sensitive to different levels of mental workload. Participants (N=14) performed a visual horizontal tracking task either alone (single-task condition) or in combination with a visual gauge monitoring task (multiple-task condition) for three minutes. On some task trials, the startle eyeblink reflex was elicited by a noise burst. Results showed that startle eyeblink was attenuated during both tasks and that the attenuation was greater during the multiple-task condition than during the single-task condition. Subjective ratings, endogenous eyeblink rate, heart period, and heart period variability provided convergent validity of the workload manipulations. The findings suggest that the startle eyeblink is sensitive to the workload demands associated with a continuous visual task. The application of startle eyeblink modulation as a workload metric and the possibility that it may be diagnostic of workload demands in different stimulus modalities is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of 'pellicular' type supports were fabricated by direct gamma-radiation-mediated graft polymerisation of styrene onto polypropylene, followed by aminomethylation. Raman spectroscopy was used for measuring the level of penetration of polystyrene graft into polypropylene, and other structural features such as density of graft and depth of functionalisation. The kinetics of the coupling of fluorenylmethylcarbamate (Fmoc)-labelled amino acids, to the aminomethylated polystyrene grafts have been measured by UV absorption followed cleavage of the Fmoc chromophore. The Raman spectroscopy results showed that for this series of experiments the calculated rate coefficient for coupling of Fmoc-labelled amino acids was primarily dependent on graft thickness, but was also influenced by the proportion of polystyrene graft to polypropylene. In general, it was also shown that with increasing loading capacity of support the calculated rate coefficient for amino-acid coupling decreased correspondingly. In addition, a support that had both a high rate coefficient and a high loading capacity was prepared from polypropylene base material with a co-continuous porous structure (high surface area). (C) 2003 Society of Chemical Industry.