14 resultados para Continuous Monitoring
em University of Queensland eSpace - Australia
Resumo:
We propose two quantum error-correction schemes which increase the maximum storage time for qubits in a system of cold-trapped ions, using a minimal number of ancillary qubits. Both schemes consider only the errors introduced by the decoherence due to spontaneous emission from the upper levels of the ions. Continuous monitoring of the ion fluorescence is used in conjunction with selective coherent feedback to eliminate these errors immediately following spontaneous emission events.
Resumo:
Leaf water potential (psi (l)) represents a good indicator of the water status of plants, and continuous monitoring of it can be useful in research and field applications such as scheduling irrigation. Changes in stem diameter (Sd) were used for monitoring psi (l) of pot-grown sorghum [Sorghum bicolor (L.) Moench] plants in a glasshouse. This method requires occasional calibration of S-d values against psi (l). Predicted values of psi (l), based on a single calibration show a good correlation with measured psi (l), values over a period of 13 d before and after the calibration. The correlation can further be improved with shorter time intervals.
Resumo:
Changes in arterial distensibility have been widely used to identify the presence of cardiovascular abnormalities like hypertension. Pulse wave velocity (PWV) has shown to be related to arterial distensibility. However, the lack of suitable techniques to measure PWV nonintrusively has impeded its clinical usefulness. Pulse transit time (PTT) is a noninvasive technique derived from the principle of PWV. PTT has shown its capabilities in cardiovascular and cardiorespiratory studies in adults. However, no known study has been conducted to understand the suitability and utility of PTT to estimate PWV in children. Two computational methods to derive PWV from PTT values obtained from 23 normotensive Caucasian children (19 males, aged 5-12 years old) from their finger and toe were conducted. Furthermore, the effects of adopting different postures on the PWV derivations were investigated. Statistical analyses were performed in comparison with two previous PWV studies conducted on children. Results revealed that PWV derived from the upper limb correlated significantly (P
Resumo:
Objective: To test the effect of liquid feeds on the responses to splanchnic ischaemia of a continuous rapid response PCO2 sensor inserted in the jejunum. Design: Prospective experimental animal study in a university research laboratory. Subjects: Adult male Wistar rats. Interventions: Adult male Wistar rats (285-425 g) were anaethetised with sodium pentobarbitone 60 mg/ kg i.p. and ventilated with 100 % oxygen and isoflurane via tracheostomy to a PaCO2 of 30-40 mmHg. A sensor was inserted into the mid-jejunum to record PCO2 every second. Distal aortic pressure was transduced. Four control rats received no feeds whilst in another four rats liquid feed was infused into the proximal jejunum at 3 ml/h. In each rat five episodes of splanchnic ischaemia were induced by 2-min elevations of an aortic sling to a mean distal aortic pressure of 30 mmHg. Measurements and main results: PCO2 elevations were always detectable, usually less than a minute from the onset of splanchnic ischaemia in both fed and unfed rats, with no difference in mean times to detectable response. In the fed rats there was a small but significant increase in the time to peak sensor response (196 +/- 16 vs. 180 +/- 12 s) and a trend towards an elevated mean baseline luminal PCO2 (67 +/- 9 vs. 55 +/- 4 mmHg). Conclusions: Brief episodes of splanchnic ischaemia were tracked successfully by a rapid response jejunal continuous PCO2 sensor during the infusion of a proprietary liquid feed preparation despite minor changes in PCO2 response characteristics and a possible elevation in baseline luminal PCO2.
Resumo:
We reviewed the use of advanced display technologies for monitoring in anesthesia. Researchers are investigating displays that integrate information and that, in some cases, also deliver the results continuously to the anesthesiologist. Integrated visual displays reveal higher-order properties of patient state and speed in responding to events, but their benefits under an intensely timeshared load is unknown. Head-mounted displays seem to shorten the time to respond to changes, but their impact on peripheral awareness and attention is unknown. Continuous auditory displays extending pulse oximetry seem to shorten response times and improve the ability to time-share other tasks, but their integration into the already noisy operative environment still needs to be tested. We reviewed the advantages and disadvantages of the three approaches, drawing on findings from other fields, such as aviation, to suggest outcomes where there are still no results for the anesthesia context. Proving that advanced patient monitoring displays improve patient outcomes is difficult, and a more realistic goal is probably to prove that such displays lead to better situational awareness, earlier responding, and less workload, all of which keep anesthesia practice away from the outer boundaries of safe operation.
Resumo:
Background Although both strength training (ST) and endurance training (ET) seem to be beneficial in type 2 diabetes mellitus (T2D), little is known about post-exercise glucose profiles. The objective of the study was to report changes in blood glucose (BG) values after a 4-month ET and ST programme now that a device for continuous glucose monitoring has become available. Materials and methods Fifteen participants, comprising four men age 56.5 +/- 0.9 years and 11 women age 57.4 +/- 0.9 years with T2D, were monitored with the MiniMed (Northridge, CA, USA) continuous glucose monitoring system (CGMS) for 48 h before and after 4 months of ET or ST. The ST consisted of three sets at the beginning, increasing to six sets per week at the end of the training period, including all major muscle groups and ET performed with an intensity of maximal oxygen uptake of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min three times a week. Results A total of 17 549 single BG measurements pretraining (619.7 +/- 39.8) and post-training (550.3 +/- 30.1) were recorded, correlating to an average of 585 +/- 25.3 potential measurements per participant at the beginning and at the end of the study. The change in BG-value between the beginning (132 mg dL(-1)) and the end (118 mg dL(-1)) for all participants was significant (P = 0.028). The improvement in BG-value for the ST programme was significant (P = 0.02) but for the ET no significant change was measured (P = 0.48). Glycaemic control improved in the ST group and the mean BG was reduced by 15.6% (Cl 3-25%). Conclusion In conclusion, the CGMS may be a useful tool in monitoring improvements in glycaemic control after different exercise programmes. Additionally, the CGMS may help to identify asymptomatic hypoglycaemia or hyperglycaemia after training programmes.
Resumo:
Marathon running is growing in popularity, and many diabetic patients are participating in various marathon races all over the world each year. This study aimed to investigate the prevalence and extent of glycemic excursions (hypo- and hyperglycemic) during a marathon run in patients with well-controlled diabetes mellitus using a continuous glucose monitoring system (CGMS). Five subjects with type 1 and one patient with type 2 diabetes mellitus were monitored with the Medtronic MiniMed CGMS during the 2002 Vienna City Marathon (n = 3) or the Fernwarme run (n = 3) long distance runs of 42.19/15.8 km. All six patients finished their course. The CGSM system was well tolerated in all patients over an average duration of 34 +/- 4.0 hours and it did not limit the patients' activities. The mean running time for the Vienna city marathon was 257 +/- 8 min (247 to 274 min) and for the Fernwarme run 134 +/- 118 min (113 to 150 min). A total of 1470 blood glucose measurements (mean 245 readings per subject) were performed. During and after the marathons frequent hypo and hyperglycemic episodes with and without clinical symptoms were measured. Our data confirm that the CGMS may help to identify asymptomatic hypoglycemia or hyperglycemia during and after a long distance run. The system may also be helpful to improve our understanding about the individual changes of glucose during and after a marathon and may protect hypoglycemic or hyperglycemic periods in future races.
Resumo:
Three experiments explored the effectiveness of continuous auditory displays, or sonifications, for conveying information about a simulated anesthetized patient's respiration. Experiment 1 established an effective respiratory sonification. Experiment 2 showed an effect of expertise in the use of respiratory sonification and revealed that some apparent differences in sonification effectiveness could be accounted for by response bias. Experiment 3 showed that sonification helps anesthesiologists to maintain high levels of awareness of the simulated patient's state while performing other tasks more effectively than when relying upon visual monitoring of the simulated patient state. Overall, sonification of patient physiology beyond traditional pulse oximetry appears to be a viable and useful adjunct to visual monitors. Actual and potential applications of this research include monitoring in a wide variety of busy critical care contexts.
Resumo:
The monitoring of infection control indicators including hospital-acquired infections is an established part of quality maintenance programmes in many health-care facilities. However, surveillance data use can be frustrated by the infrequent nature of many infections. Traditional methods of analysis often provide delayed identification of increasing infection occurrence, placing patients at preventable risk. The application of Shewhart, Cumulative Sum (CUSUM) and Exponentially Weighted Moving Average (EWMA) statistical process control charts to the monitoring of indicator infections allows continuous real-time assessment. The Shewhart chart will detect large changes, while CUSUM and EWMA methods are more suited to recognition of small to moderate sustained change. When used together, Shewhart and EWMA methods are ideal for monitoring bacteraemia and multiresistant organism rates. Shewhart and CUSUM charts are suitable for surgical infection surveillance.
Resumo:
Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.
Resumo:
For the managers of a region as large as the Great Barrier Reef, it is a challenge to develop a cost effective monitoring program, with appropriate temporal and spatial resolution to detect changes in water quality. The current study compares water quality data (phytoplankton abundance and water clarity) from remote sensing with field sampling (continuous underway profiles of water quality and fixed site sampling) at different spatial scales in the Great Barrier Reef north of Mackay (20 degrees S). Five transects (20-30 km long) were conducted from clean oceanic water to the turbid waters adjacent to the mainland. The different data sources demonstrated high correlations when compared on a similar spatial scale (18 fixed sites). However, each data source also contributed unique information that could not be obtained by the other techniques. A combination of remote sensing, underway sampling and fixed stations will deliver the best spatial and temporal monitoring of water quality in the Great Barrier Reef. (c) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Registration of births, recording deaths by age, sex and cause, and calculating mortality levels and differentials are fundamental to evidence-based health policy, monitoring and evaluation. Yet few of the countries with the greatest need for these data have functioning systems to produce them despite legislation providing for the establishment and maintenance of vital registration. Sample vital registration (SVR), when applied in conjunction with validated verbal autopsy, procedures and implemented in a nationally representative sample of population clusters represents an affordable, cost-effective, and sustainable short- and medium-term solution to this problem. SVR complements other information sources by producing age-, sex-, and cause-specific mortality data that are more complete and continuous than those currently available. The tools and methods employed in an SVR system, however, are imperfect and require rigorous validation and continuous quality assurance; sampling strategies for SVR are also still evolving. Nonetheless, interest in establishing SVR is rapidly growing in Africa and Asia. Better systems for reporting and recording data on vital events will be sustainable only if developed hand-in-hand with existing health information strategies at the national and district levels; governance structures; and agendas for social research and development monitoring. If the global community wishes to have mortality measurements 5 or 10 years hence, the foundation stones of SVR must be laid today.
Resumo:
The Continuous Plankton Recorder (CPR) survey, operated by the Sir Alister Hardy Foundation for Ocean Science (SAHFOS), is the largest plankton monitoring programme in the world and has spanned > 70 yr. The dataset contains information from -200 000 samples, with over 2.3 million records of individual taxa. Here we outline the evolution of the CPR database through changes in technology, and how this has increased data access. Recent high-impact publications and the expanded role of CPR data in marine management demonstrate the usefulness of the dataset. We argue that solely supplying data to the research community is not sufficient in the current research climate; to promote wider use, additional tools need to be developed to provide visual representation and summary statistics. We outline 2 software visualisation tools, SAHFOS WinCPR and the digital CPR Atlas, which provide access to CPR data for both researchers and non-plankton specialists. We also describe future directions of the database, data policy and the development of visualisation tools. We believe that the approach at SAHFOS to increase data accessibility and provide new visualisation tools has enhanced awareness of the data and led to the financial security of the organisation; it also provides a good model of how long-term monitoring programmes can evolve to help secure their future.
Resumo:
The continuous plankton recorder (CPR) survey is the largest multi-decadal plankton monitoring programme in the world. It was initiated in 1931 and by the end of 2004 had counted 207,619 samples and identified 437 phyto- and zoo-plankton taxa throughout the North Atlantic. CPR data are used extensively by the research community and in recent years have been used increasingly to underpin marine management. Here, we take a critical look at how best to use CPR data. We first describe the CPR itself, CPR sampling, and plankton counting procedures. We discuss the spatial and temporal biases in the Survey, summarise environmental data that have not previously been available, and describe the new data access policy. We supply information essential to using CPR data, including descriptions of each CPR taxonomic entity., the idiosyncrasies associated with counting many of the taxa, the logic behind taxonomic changes in the Survey, the semi-quantitative nature of CPR sampling, and recommendations on choosing the spatial and temporal scale of study. This forms the basis for a broader discussion on how to use CPR data for deriving ecologically meaningful indices based on size, functional groups and biomass that can be used to support research and management. This contribution should be useful for plankton ecologists, modellers and policy makers that actively use CPR data. (c) 2005 Elsevier Ltd. All rights reserved.