104 resultados para Condensing power capacity
em University of Queensland eSpace - Australia
Resumo:
The linear relationship between work accomplished (W-lim) and time to exhaustion (t(lim)) can be described by the equation: W-lim = a + CP.t(lim). Critical power (CP) is the slope of this line and is thought to represent a maximum rate of ATP synthesis without exhaustion, presumably an inherent characteristic of the aerobic energy system. The present investigation determined whether the choice of predictive tests would elicit significant differences in the estimated CP. Ten female physical education students completed, in random order and on consecutive days, five art-out predictive tests at preselected constant-power outputs. Predictive tests were performed on an electrically-braked cycle ergometer and power loadings were individually chosen so as to induce fatigue within approximately 1-10 mins. CP was derived by fitting the linear W-lim-t(lim) regression and calculated three ways: 1) using the first, third and fifth W-lim-t(lim) coordinates (I-135), 2) using coordinates from the three highest power outputs (I-123; mean t(lim) = 68-193 s) and 3) using coordinates from the lowest power outputs (I-345; mean t(lim) = 193-485 s). Repeated measures ANOVA revealed that CPI123 (201.0 +/- 37.9W) > CPI135 (176.1 +/- 27.6W) > CPI345 (164.0 +/- 22.8W) (P < 0.05). When the three sets of data were used to fit the hyperbolic Power-t(lim) regression, statistically significant differences between each CP were also found (P < 0.05). The shorter the predictive trials, the greater the slope of the W-lim-t(lim) regression; possibly because of the greater influence of 'aerobic inertia' on these trials. This may explain why CP has failed to represent a maximal, sustainable work rate. The present findings suggest that if CP is to represent the highest power output that an individual can maintain for a very long time without fatigue then CP should be calculated over a range of predictive tests in which the influence of aerobic inertia is minimised.
Resumo:
The standard critical power test protocol on the cycle prescribes a series of trials to exhaustion, each at a different but constant power setting. Recently the protocol has been modified and applied to a series of trials to exhaustion each at a different ramp incremental rate. This study was undertaken to compare critical power and anaerobic work capacity estimates in the same group of subjects when derived from the two protocols. Ten male subjects of mixed athletic ability cycled to exhaustion on eight occasions in randomized order over a 3-wk period. Four trials were performed at differing constant power settings and four trials on differing ramp incremental rates. Both critical power and anaerobic work capacity were estimated for each subject by curve fitting of the ramp model and of three versions of the constant power model. After adjusting for inter-subject variability, no significant differences were detected between critical power estimates or between anaerobic work capacity estimates from any model formulation or from the two protocols. It is concluded that both the ramp and constant power protocols produce equivalent estimates for critical power and anaerobic work capacity.
Resumo:
An important functional and evolutionary constraint on the physical performance of vertebrates is believed to be the trade-off between speed and endurance capacity. However, despite the pervasiveness of physiological arguments, most studies have found no evidence of the trade-off when tested at the whole-animal level. We investigated the existence of this trade-off at the whole-muscle level, the presumed site of this physiological conflict, by examining inter-individual variation in both maximum power output and fatigue resistance for mouse extensor digitorum longus (EDL) muscle using the work-loop technique. We found negative correlations between several measures of in vitro maximum power output and force production with fatigue resistance for individual mouse EDL muscles, indicating functional trade-offs between these performance parameters. We suggest that this trade-off detected at the whole-muscle level has imposed an important constraint on the evolution of vertebrate physical performance.
Resumo:
Acetazolamide (Acz) is used at altitude to prevent acute mountain sickness, but its effect on exercise capacity under hypoxic conditions is uncertain. Nine healthy men completed this double-blind, randomized, crossover study. All subjects underwent incremental exercise to exhaustion with an inspired O-2 fraction of 0.13, hypoxic ventilatory responses, and hypercapnic ventilatory responses after Acz (500 mg twice daily for 5 doses) and placebo. Maximum power of 203 +/- 38 (SD) Won Acz was less than the placebo value of 225 +/- 40 W (P < 0.01). At peak exercise, arterialized capillary pH was lower and PO2 higher on Acz (P < 0.01). Ventilation was 118.6 +/- 20.0 l/min at the maximal power on Acz and 102.4 +/- 20.7 l/min at the same power on placebo (P < 0.02), and Borg score for leg fatigue was increased on Acz (P < 0.02), with no difference in Borg score for dyspnea. Hypercapnic ventilatory response on Acz was greater (P < 0.02), whereas hypoxic ventilatory response was unchanged. During hypoxic exercise, Acz reduced exercise capacity associated with increased perception of leg fatigue. Despite increased ventilation, dyspnea was not increased.
Resumo:
Background: There is a recognized need to move from mortality to morbidity outcome predictions following traumatic injury. However, there are few morbidity outcome prediction scoring methods and these fail to incorporate important comorbidities or cofactors. This study aims to develop and evaluate a method that includes such variables. Methods: This was a consecutive case series registered in the Queensland Trauma Registry that consented to a prospective 12-month telephone conducted follow-up study. A multivariable statistical model was developed relating Trauma Registry data to trichotomized 12-month post-injury outcome (categories: no limitations, minor limitations and major limitations). Cross-validation techniques using successive single hold-out samples were then conducted to evaluate the model's predictive capabilities. Results: In total, 619 participated, with 337 (54%) experiencing no limitations, 101 (16%) experiencing minor limitations and 181 (29%) experiencing major limitations 12 months after injury. The final parsimonious multivariable statistical model included whether the injury was in the lower extremity body region, injury severity, age, length of hospital stay, pulse at admission and whether the participant was admitted to an intensive care unit. This model explained 21% of the variability in post-injury outcome. Predictively, 64% of those with no limitations, 18% of those with minor limitations and 37% of those with major limitations were correctly identified. Conclusion: Although carefully developed, this statistical model lacks the predictive power necessary for its use as a basis of a useful prognostic tool. Further research is required to identify variables other than those routinely used in the Trauma Registry to develop a model with the necessary predictive utility.
Resumo:
Calcium oxide has been identified to be one of the best candidates for CO2 capture in zero-emission power-generation systems. However, it suffers a well-known problem of loss-in-capacity (i.e., its capacity of CO2 capture decreases after it undergoes cycles of carbonation/decarbonation). This problem is a potential obstacle to the adoption of the new technologies. This paper proposes a method of fabricating a CaO-based adsorbent without the problem of loss-in-capacity. An adsorbent was fabricated using the method and tested on a thermogravimetric analyzer. It was shown that the sorbent attained a utilization efficiency of more than 90% after 9 cycles of carbonation/decarbonation.
Resumo:
In this paper the performance of a multiple input multiple output (MIMO) wireless communication system operating in an indoor environment, featuring both line of sight (LOS) and non-line of sight (NLOS) signal propagation, is assessed. In the model the scattering objects are assumed to be uniformly distributed in an area surrounding the transmitting and receiving array antennas. Mutual coupling effects in the arrays are treated in an exact manner. However interactions with scattering objects are taken into account via a single bounce approach. Computer simulations are carried out for the system capacity for varying inter-element spacing in the receiving array for assumed values of LOS/NLOS power fraction and signal to noise ratio (SNR).
Resumo:
In indoor environments the properties of communication channel are affected by the presence of various objects which block the Line Of Sight signal propagation. For example, this occurs because of presence of movement of humans and furniture. In this paper, the effect of reflection and scattering due to the presence of such objects is studied with respect to the capacity of a multiple input multiple output (MIMO) wireless system. The carried out investigations are performed by applying a simple electromagnetic model, in which transmitting and receiving antennas of MIMO system, as well as signal blocking objects, are represented by wire dipoles. In order to provide a fair assessment, calculations of MIMO capacity are performed under both fixed transmitted power and fixed received power conditions.
Resumo:
The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55–70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and 1 laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R= .66), lower body strength (sit to stand, R= .80) and functional capacity (Canadian Step Test, R= .92), but not for leg power (single timed chair rise, R= .28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r= .68, p< .05), and for the step test (cf PWC140, r= −.60, p< .001), but not for the lift and reach (cf 1RM bench press, r= .43, p> .05), balance (r= −.13, −.18, .23) and rate of force development tests (r= −.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.
Resumo:
Power system real time security assessment is one of the fundamental modules of the electricity markets. Typically, when a contingency occurs, it is required that security assessment and enhancement module shall be ready for action within about 20 minutes’ time to meet the real time requirement. The recent California black out again highlighted the importance of system security. This paper proposed an approach for power system security assessment and enhancement based on the information provided from the pre-defined system parameter space. The proposed scheme opens up an efficient way for real time security assessment and enhancement in a competitive electricity market for single contingency case
Resumo:
The BR algorithm is a novel and efficient method to find all eigenvalues of upper Hessenberg matrices and has never been applied to eigenanalysis for power system small signal stability. This paper analyzes differences between the BR and the QR algorithms with performance comparison in terms of CPU time based on stopping criteria and storage requirement. The BR algorithm utilizes accelerating strategies to improve its performance when computing eigenvalues of narrowly banded, nearly tridiagonal upper Hessenberg matrices. These strategies significantly reduce the computation time at a reasonable level of precision. Compared with the QR algorithm, the BR algorithm requires fewer iteration steps and less storage space without depriving of appropriate precision in solving eigenvalue problems of large-scale power systems. Numerical examples demonstrate the efficiency of the BR algorithm in pursuing eigenanalysis tasks of 39-, 68-, 115-, 300-, and 600-bus systems. Experiment results suggest that the BR algorithm is a more efficient algorithm for large-scale power system small signal stability eigenanalysis.
Resumo:
Multi-frequency bioimpedance analysis (MFBIA) was used to determine the impedance, reactance and resistance of 103 lamb carcasses (17.1-34.2 kg) immediately after slaughter and evisceration. Carcasses were halved, frozen and one half subsequently homogenized and analysed for water, crude protein and fat content. Three measures of carcass length were obtained. Diagonal length between the electrodes (right side biceps femoris to left side of neck) explained a greater proportion of the variance in water mass than did estimates of spinal length and was selected for use in the index L-2/Z to predict the mass of chemical components in the carcass. Use of impedance (Z) measured at the characteristic frequency (Z(c)) instead of 50 kHz (Z(50)) did not improve the power of the model to predict the mass of water, protein or fat in the carcass. While L-2/Z(50) explained a significant proportion of variation in the masses of body water (r(2) 0.64), protein (r(2) 0.34) and fat (r(2) 0.35), its inclusion in multi-variate indices offered small or no increases in predictive capacity when hot carcass weight (HCW) and a measure of rib fat-depth (GR) were present in the model. Optimized equations were able to account for 65-90 % of the variance observed in the weight of chemical components in the carcass. It is concluded that single frequency impedance data do not provide better prediction of carcass composition than can be obtained from measures of HCW and GR. Indices of intracellular water mass derived from impedance at zero frequency and the characteristic frequency explained a similar proportion of the variance in carcass protein mass as did the index L-2/Z(50).