171 resultados para Computer Sciences Corporation
em University of Queensland eSpace - Australia
Resumo:
Objective: The objectives were to determine the postural consequences of varying computer monitor height and to describe self-selected monitor heights and postures. Design: The design involved experimental manipulation of computer monitor height, description of self-selected heights, and measurement of posture and gaze angles. Background. Disagreement exists with regard to the appropriate height of computer monitors. It is known that users alter both head orientation and gaze angle in response to changes in monitor height; however the relative contribution of atlanto-occipital and cervical flexion to the change in head rotation is unknown. No information is available with regard to self-selected monitor heights. Methods. Twelve students performed a tracking task with the monitor placed at three different heights. The subjects then completed eight trials in which monitor height was first self-selected. Sagittal postural and gaze angle data were determined by digitizing markers defining a two-dimensional three-link model of the trunk, cervical spine and head. Results. The 27 degrees change in monitor height imposed was, on average, accommodated by 18 degrees of head inclination and a 9 degrees change in gaze angle relative to the head. The change in head inclination was achieved by a 6 degrees change in trunk inclination, a 4 degrees change in cervical flexion, and a 7 degrees change in atlanto-occipital flexion. The self-selected height varied depending on the initial monitor height and inclination. Conclusions. Self-selected monitor heights were lower than current 'eye-level' recommendations. Lower monitor heights are likely to reduce both visual and musculoskeletal discomfort. Relevance Musculoskeletal and visual discomfort may be reduced by placing computer monitors lower than currently recommended. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
RWMODEL II simulates the Rescorla-Wagner model of Pavlovian conditioning. It is written in Delphi and runs under Windows 3.1 and Windows 95. The program was designed for novice and expert users and can be employed in teaching, as well as in research. It is user friendly and requires a minimal level of computer literacy but is sufficiently flexible to permit a wide range of simulations. It allows the display of empirical data, against which predictions from the model can be validated.
Resumo:
Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.
Resumo:
Computer assisted learning has an important role in the teaching of pharmacokinetics to health sciences students because it transfers the emphasis from the purely mathematical domain to an 'experiential' domain in which graphical and symbolic representations of actions and their consequences form the major focus for learning. Basic pharmacokinetic concepts can be taught by experimenting with the interplay between dose and dosage interval with drug absorption (e.g. absorption rate, bioavailability), drug distribution (e.g. volume of distribution, protein binding) and drug elimination (e.g. clearance) on drug concentrations using library ('canned') pharmacokinetic models. Such 'what if' approaches are found in calculator-simulators such as PharmaCalc, Practical Pharmacokinetics and PK Solutions. Others such as SAAM II, ModelMaker, and Stella represent the 'systems dynamics' genre, which requires the user to conceptualise a problem and formulate the model on-screen using symbols, icons, and directional arrows. The choice of software should be determined by the aims of the subject/course, the experience and background of the students in pharmacokinetics, and institutional factors including price and networking capabilities of the package(s). Enhanced learning may result if the computer teaching of pharmacokinetics is supported by tutorials, especially where the techniques are applied to solving problems in which the link with healthcare practices is clearly established.
Resumo:
In this paper, we apply the canonical decomposition of two-qubit unitaries to find pulse schemes to control the proposed Kane quantum computer. We explicitly find pulse sequences for the controlled-NOT, swap, square root of swap, and controlled Z rotations. We analyze the speed and fidelity of these gates, both of which compare favorably to existing schemes. The pulse sequences presented in this paper are theoretically faster, with higher fidelity, and simpler. Any two-qubit gate may be easily found and implemented using similar pulse sequences. Numerical simulation is used to verify the accuracy of each pulse scheme.
Resumo:
Purpose: The aim of this project was to design and evaluate a system that would produce tailored information for stroke patients and their carers, customised according to their informational needs, and facilitate communication between the patient and, health professional. Method: A human factors development approach was used to develop a computer system, which dynamically compiles stroke education booklets for patients and carers. Patients and carers are able to select the topics about which they wish to receive information, the amount of information they want, and the font size of the printed booklet. The system is designed so that the health professional interacts with it, thereby providing opportunities for communication between the health professional and patient/carer at a number of points in time. Results: Preliminary evaluation of the system by health professionals, patients and carers was positive. A randomised controlled trial that examines the effect of the system on patient and carer outcomes is underway. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We calculate the electron exchange coupling for a phosphorus donor pair in silicon perturbed by a J-gate potential and the boundary effects of the silicon host geometry. In addition to the electron-electron exchange interaction we also calculate the contact hyperfine interaction between the donor nucleus and electron as a function of the varying experimental conditions. Donor separation, depth of the P nuclei below the silicon oxide layer and J-gate voltage become decisive factors in determining the strength of both the exchange coupling and hyperfine interaction-both crucial components for qubit operations in the Kane quantum computer. These calculations were performed using an anisotropic effective-mass Hamiltonian approach. The behaviour of the donor exchange coupling as a function of the parameters varied in this work provides relevant information for the experimental design of these devices.
Resumo:
In this paper we investigate the effect of dephasing on proposed quantum gates for the solid-state Kane quantum computing architecture. Using a simple model of the decoherence, we find that the typical error in a controlled-NOT gate is 8.3x10(-5). We also compute the fidelities of Z, X, swap, and controlled Z operations under a variety of dephasing rates. We show that these numerical results are comparable with the error threshold required for fault tolerant quantum computation.