9 resultados para Cilia and ciliary motion

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hallucinogenic serotonin(IA&2A) agonist psilocybin is known for its ability to induce illusions of motion in otherwise stationary objects or textured surfaces. This study investigated the effect of psilocybin on local and global motion processing in nine human volunteers. Using a forced choice direction of motion discrimination task we show that psilocybin selectively impairs coherence sensitivity for random dot patterns, likely mediated by high-level global motion detectors, but not contrast sensitivity for drifting gratings, believed to be mediated by low-level detectors. These results are in line with those observed within schizophrenic populations and are discussed in respect to the proposition that psilocybin may provide a model to investigate clinical psychosis and the pharmacological underpinnings of visual perception in normal populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sponge Tetilla sp. (Tetractinomorpha: Tetillidae) is a common species in the eastern Mediterranean. This sponge inhabits four different habitat types differing in wave impact and irradiance levels. Two of these habitats (a shallow cave and deep water) are characterized by relatively calm water, whereas the other two (shallow exposed site and tide pools) are in turbulent water with high energy flow. The present study examined the influence of physical (depth, illumination and water motion) and biotic factors on morphology, skeletal plasticity and reproductive traits among the four spatially separated populations. Sponges from tidal pools had significantly larger body volume than sponges from deep water and from shallow caves (ANOVA: tidal-deep P< 0.0001; tidal-shallow caves P< 0.05). Sponges from exposed habitats were significantly larger than deep-water sponges (ANOVA: P=0.01). In addition, individuals from tide pools and from the exposed habitat had a significantly higher proportion of structural silica than sponges from the calmer deep water and from the cave sites. Oxea spicules in sponges from the calm habitats were significantly shorter than in those from the tidal pools and the exposed habitats. The percentage of spicules out of a sponge's dry weight in individuals transplanted from deep (calm) to shallow (turbulent) water significantly increased by 21.9&PLUSMN; 12.9%. The new spicule percentage did not differ significantly from that of sponges originally from shallow water. Oocyte diameter differed significantly between habitats. The maximal size of mature eggs was found in deep-water sponges in June (97&PLUSMN; 5 μ m). In the shallow habitats, a smaller maximal oocyte diameter was found in the cave, in May (56.5&PLUSMN; 3 μ m). Furthermore, oocyte density in shallow-water sponges was highest in May and decreased in June (with 88.2&PLUSMN; 9 and 19.3&PLUSMN; 9 oocytes mm(-2), respectively). At the same time (June), oocyte density of deep-water sponges had just reached its maximum (155&PLUSMN; 33.7 oocytes mm(-2)). The difference in oocyte size and density between deep- and shallow-water individuals indicates an earlier gamete release in the shallow sponge population. The results suggest that plasticity in skeletal design of this sponge indicates a trade off between spicule production and investment in reproduction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: left ventricular wall motion on 2d echo (2de) is usually scored visually. we sought to examine the determinants of visually assessed wall motion scoring on 2de by comparison with myocardial thickening quantified on MRI. Methods: using a 16 segment model, we studied 287 segments in 30 patients aged 61+/ -11 years (6 female), with ischaemic LV dysfunction (defined by at least 2 segments dysfunctional on 2de). 2de was performed in 5 views and wall motion scores (WMS) assigned: 1 (normal) 103 segments, 2 (hypokinetic) 93 segments, 3 (akinetic) 87 segments. MRI was used to measure end systolic wall thickness (ESWT), end diastolic wall thickness (EDWT) and percentage systolic wall thickening (SWT%) in the plane of the 2de and to assess WMS in the same planes visually. No patient had a clinical ischemic event between the tests. Results: visual assessment of wall motion by 2de and MRI showed moderate agreement (kappa = 0.425). Resting 2de wall motion correlated significantly (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Streaming video application requires high security as well as high computational performance. In video encryption, traditional selective algorithms have been used to partially encrypt the relatively important data in order to satisfy the streaming performance requirement. Most video selective encryption algorithms are inherited from still image encryption algorithms, the encryption on motion vector data is not considered. The assumption is that motion vector data are not as important as pixel image data. Unfortunately, in some cases, motion vector itself may be sufficient enough to leak out useful video information. Normally motion vector data consume over half of the whole video stream bandwidth, neglecting their security may be unwise. In this paper, we target this security problem and illustrate attacks at two different levels that can restore useful video information using motion vectors only. Further, an information analysis is made and a motion vector information model is built. Based on this model, we describe a new motion vector encryption algorithm called MVEA. We show the experimental results of MVEA. The security strength and performance of the algorithm are also evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A complex response of the trunk muscles occurs to restore equilibrium in response to movement of the support surface. Intra-abdominal pressure (IAP) is considered to contribute to control of the trunk. This study investigated the contribution of IAP to the postural response to multidirection support-surface translation. IAP was recorded with a thin-film pressure transducer inserted via the nose into the stomach and trunk motion was recorded with an optoelectronic system with markers over the spinous process of L1. A pattern of trunk movement was recorded in response to the support-surface translations that was consistent with a 'hip' strategy of postural control. The trunk moved in a manner appropriate to move the centre of gravity over the new base of support. IAP was increased with movement in each direction, but varied in timing and amplitude between translation directions. In general, the IAP was greater with translations in the sagittal plane compared to the frontal plane and was initiated earlier for translations in the backward direction. These data indicate that IAP contributes to the postural response associated with support-surface translation and suggest that this is consistent with stiffening the spine. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An entire female English bull terrier, aged five years and one month, was diagnosed with polycystic kidney disease by renal ultrasonography. It had thickening and abnormal motion of the mitral valve on 2D and M mode echocardiography, and left ventricular outflow tract obstruction, characterised by turbulence in the left ventricular outflow tract and elevated aortic blood flow velocity, detected by colour flow and spectral Doppler echocardiography, respectively. Two years later, haematology, serum biochemistry and urinalysis data suggested the presence of compensated renal failure. The dog was euthanased at 10 years and eight months of age, with haematology, serum biochemistry and urinalysis data indicating decompensated chronic renal failure. Postmortem examination confirmed polycystic kidney disease, chronic renal disease, mitral and aortic valvular myxomatous degeneration, and mixed mammary neoplasia. This case demonstrates that bull terriers with polycystic kidney disease may develop associated chronic renal failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The skyrmions in SU(N) quantum Hall (QH) system are discussed. By analyzing the gauge field structure and the topological properties of this QH system it is pointed out that in the SU(N) QH system there can exist (N-1) types of skyrmion structures, instead of only one type of skyrmions. In this paper, by means of the Abelian projections according to the (N-1) Cartan subalgebra local bases, we obtain the (N-1) U(1) electromagnetic field tensors in the SU(N) gauge field of the QH system, and then derive (N-1) types of skyrmion structures from these U(1) sub-field tensors. Furthermore, in light of the phi-mapping topological current method, the topological charges and the motion of these skyrmions are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various exercises are used to retrain the abdominal muscles in the management of low back pain and other musculoskeletal disorders. However. few studies have directly investigated the activity of all the abdominal muscles or the recruitment of regions of the abdominal muscles during these manoeuvres. This study examined the activity of different regions of transversus abdominis (TrA), obliquus internus (OI) and externus abdominis (OE), and rectus abdominis (RA), and movement of lumbar spine, pelvis and abdomen during inward movement of the lower abdominal wall, abdominal bracing, pelvic tilting, and inward movement of the lower and upper abdominal wall. Inward movement of the lower abdominal wall in supine produced greater activity of TrA compared to OI. OE and RA. During posterior pelvic tilting. middle OI was most active and with abdominal bracing. OE was predominately recruited. Regions of TrA were recruited differentially and in inverse relationship between lumbopelvic motion and TrA electromyography (EMG) was found. This study indicates that inward movement of the abdominal wall in supine produces the most independent activity of TrA relative to the other abdominal muscle, recruitment varies between regions of TrA, and observation of abdominal and lumbopelvic motion may assist in evalation of exercise performance. (c) 2004 Elsevier Ltd. All rights reserved.