20 resultados para Chromatography, DEAE-Cellulose
em University of Queensland eSpace - Australia
Resumo:
This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.
Resumo:
A sensitive and reproducible solid-phase extraction (SPE) method for the quantification of oxycodone in human plasma was developed. Varian Certify SPE cartridges containing both C-8 and benzoic acid functional groups were the most suitable for the extraction of oxycodone and codeine (internal standard), with consistently high (greater than or equal to 80%) and reproducible recoveries. The elution mobile phase consisted of 1.2 ml of butyl chloride-isopropanol (80:20, v/v) containing 2% ammonia. The quantification limit for oxycodone was 5.3 pmol on-column. Within-day and inter-day coefficients of variation were 1.2% and 6.8% respectively for 284 nM oxycodone and 9.5% and 6.2% respectively for 28.4 nM oxycodone using 0.5-ml plasma aliquots. (C) 1998 Elsevier Science BN. All rights reserved.
Resumo:
A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently
Resumo:
Mycophenolic acid is an immunosuppressant administered as a bioavailable ester, mycophenolate mofetil. The pharmacokinetics of mycophenolic acid have been reported to be variable. Accurate measurement of concentrations of this drug could be important to adjust doses. The aim of this study was to compare the enzyme-multiplied immunoassay technique (EMIT [Dade Behring; San Jose, CA, U.S.A.]) for mycophenolic acid with a high-performance liquid chromatographic (HPLC) assay using samples collected from renal transplant recipients. The HPLC assay used solid phase extraction and a C18 stationary phase with ultraviolet (UV) detection (254 nm). The immunoassay required no manual sample preparation. Plasma samples (n = 102) from seven patients, collected at various times after a dose, were analyzed using both methods. Both assays fulfilled quality-control criteria. Higher concentrations were consistently measured in patient samples when using EMIT. The mean (+/- standard deviation [SD]) bias (EMIT-HPLC) was 1.88 +/- 0.86 mg/L. The differences in concentrations were higher in the middle of a dosage interval, suggesting that a metabolite might have been responsible for overestimation. Measurement of glucuronide concentrations by HPLC demonstrated only a weak correlation between assay differences and glucuronide concentrations. If the crossreacting substance is active, EMIT could provide a superior measure of immunosuppression; if inactive, further work is needed to improve antibody specificity. In conclusion, it was found that EMIT overestimates the concentration of mycophenolic acid in plasma samples from renal transplant recipients compared with HPLC analysis.
Resumo:
A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1(R)) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was
Resumo:
To facilitate the investigation of free mycophenolic acid concentrations we developed a high-performance liquid chromatography tandem mass spectrometry method using indomethacin as an internal standard. Free drug was isolated from plasma samples (500 mul) using ultrafiltration, The analytes were extracted from the ultrafiltrate (200 mul) using C-18 solid-phase extraction. Detection was by selected reactant monitoring of mycophenolic acid (m/z 318.9-->190.9) and the internal standard (m/z 356.0-->297.1) with an atmospheric pressure chemical ionisation interface. The total chromatographic analysis time was 12 min. The method was found to be linear over the range investigated, 2.5-200 mug/l (r>0.990, n=6). The relative recovery of the method for the control samples studied (7.5, 40.0 and 150 mug/l) ranged from 95 to 104%. The imprecision of the method, expressed in terms of intra- and inter-day coefficients of variation, was
Resumo:
This paper describes the application of two relatively new diagnostic techniques for the determination of insulation condition in aged transformers. The techniques are (a) measurements of interfacial polarization spectra by a DC method and (b) measurements of molecular weight and its distribution by gel permeation chromatography. Several other electrical properties of the cellulose polymer were also investigated. Samples were obtained from a retired power transformer and they were analysed by the developed techniques. Six distribution transformers were also tested with the interfacial polarization spectra measurement technique, and the molecular weight of paper/pressboard samples from these transformers were also measured by the gel permeation chromatography. The variation of the results through different locations in a power transformer is discussed in this paper. The possible correlation between different measured properties was investigated and discussed in this paper.
Resumo:
We have utilised the combination of sensitivity and specificity afforded by coupling high-performance liquid chromatography (HPLC) to a tandem mass spectrometer (MS-MS) to produce an assay which is suitable for assaying glutathione (GSH) concentrations in liver tissue. The sensitivity suggests it may also be suitable for extrahepatic tissues, The method has been validated for GSH using mouse liver samples and also allows the assay of GSSG. The stability of GSH under conditions relevant to the assay has been determined. A 20-mul amount of a diluted methanol extract of tissue is injected with detection limits of 0.2 pmol for GSH and 2 pmol for GSSG. The HPLC uses an Altima C-18 (150X4.6 mm, 5 mum) column at 35 degreesC. Chromatography utilises a linear gradient from 0 to 10% methanol in 0.1% formic acid over 5 min, with a final isocratic stage holding at 10% methanol for 5 min. Total flow rate is 0.8 ml/min. The transition from the M+H ion (308.1 m/z for GSH, and 613.3 m/z for GSSG) to the 162.0 m/z (GSH) and 355.3 m/z (GSSG) fragments are monitored. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The objective of this review is to summarize developments in the use of quantitative affinity chromatography to determine equilibrium constants for solute interactions of biological interest. Affinity chromatography is an extremely versatile method for characterizing interactions between dissimilar reactants because the biospecificity incorporated into the design of the affinity matrix ensures applicability of the method regardless of the relative sizes of the two reacting solutes. Adoption of different experimental strategies, such as column chromatography, simple partition equilibrium experiments, solid-phase immunoassay, and biosensor technology, has led to a situation whereby affinity chromatography affords a means of characterizing interactions governed by an extremely broad range of binding affinities-relatively weak interactions (binding constants below 10(3) M-1) through to interactions with binding constants in excess of 10(9) M-1. In addition to its important role in solute separation and purification, affinity chromatography thus also possesses considerable potential for investigating the functional roles of the reactants thereby purified. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
We report here a validated method for the quantification of a new immunosuppressant drug, everolimus (SDZ RAD), using HPLC-tandem mass spectrometry. Whole blood samples (500 mul) were prepared by protein precipitation, followed by C-18 solid-phase extraction. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface operating in positive ionization mode. The assay was linear from 0.5 to 100 mug/l (r(2) > 0.996, n = 9). The analytical recovery and inter-day imprecision, determined using whole blood quality control samples (n = 5) at 0.5, 1.2, 20.0, and 75.0 mug/l, was 100.3-105.4% and less than or equal to7.6%, respectively. The assay had a mean relative recovery of 94.8 +/- 3.8%. Extracted samples were stable for up to 24 h. Fortified everolimus blood samples were stable at -80 degreesC for at least 8 months and everolimus was found to be stable in blood when taken through at least three freeze-thaw cycles. The reported method provides accurate, precise and specific measurement of everolimus in blood over a wide analytical range and is currently supporting phase 11 and III clinical trials. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
An active form of the Dengue virus protease NS3 (CF40.Gly.NS3pro) was expressed in Escherichia coli. This construct consists of a critical 40 amino acid cofactor domain from NS2B fused to the N-terminal 184 amino acid protease domain of NS3 via a flexible, covalent linker (Gly(4)SerGly(4)). The recombinantly produced protein is soluble and has a hexa-histidine tag engineered at the N-terminus for ease of purification using metal affinity chromatography. However, the presence of lower molecular weight impurities after affinity chromatography indicated the need for additional purification steps. The consistent appearance of these impurities suggested that they may be the products of proteolysis and/or auto-proteolysis. The latter possibility was subsequently excluded by the observation of the same impurities in a purified, catalytically inactive form of the recombinant protease (CF40.Gly.NS3pro.SA). Further analysis indicated that these impurities may represent premature translation termination products. Regardless of their origin, they were shown to form various sized aggregates with full-length CF40.Gly.NS3pro that can be separated by size exclusion chromatography, yielding fractions of active protease of sufficient purity for crystallisation trials. The ultimate goal of these studies is to obtain a crystal structure of a catalytically active form of the Dengue virus NS3 protease for structure-based drug design. (C) 2002 Elsevier Science (USA). All rights reserved.