64 resultados para COMPARATOR PHARMACEUTICAL PRODUCTS
em University of Queensland eSpace - Australia
Resumo:
Aims The penetration of active ingredients from topically applied anti-inflammatory pharmaceutical products into tissues below the skin is the basis of their therapeutic efficacy. There is still controversy as to whether these agents are capable of direct penetration by diffusion through the tissues or whether redistribution in the systemic circulation is responsible for their tissue deposition below the application site. Methods The extent of direct penetration of salicylate from commercial ester and salt formulations into the dermal and subcutaneous tissue of human volunteers was determined using the technique of cutaneous microdialysis. We also examined differences in the extent of hydrolysis of the methylester of salicylate applied topically in human volunteers and in vitro skin diffusion cells using full-thickness skin and epidermal membranes. Results The present study showed that whilst significant levels of salicylate could be detected in the dermis and subcutaneous tissue of volunteers treated with the methylsalicylate formulation, negligible levels of salicylate were seen following application of the triethanolamine salicylate formulation. The tissue levels of salicylate from the methylsalicylate formulation were approx. 30-fold higher than the plasma concentrations. Conclusion The absorption and tissue concentration profiles for the commercial methylsalicylate formulation are indicative of direct tissue penetration and not solely redistribution by the systemic blood supply.
Resumo:
In a previous paper, Hoornaert et al. (Powder Technol. 96 (1998); 116-128) presented data from granulation experiments performed in a 50 L Lodige high shear mixer. In this study that same data was simulated with a population balance model. Based on an analysis of the experimental data, the granulation process was divided into three separate stages: nucleation, induction, and coalescence growth. These three stages were then simulated separately, with promising results. it is possible to derive a kernel that fit both the induction and the coalescence growth stage. Modeling the nucleation stage proved to be more challenging due to the complex mechanism of nucleus formation. From this work some recommendations are made for the improvement of this type of model.
Resumo:
The mechanical properties of a range of agglomerates and particulate coatings have been measured using a nanoindenter. The effect of formulation properties such as powder and binder properties on coating hardness is described. An attempt is also made to measure the fracture hardness with the nanoindenter. The use of indentation technology to measure fundamental agglomerate properties is critically analysed. Based on the indentation measurements and standard attrition test results, the coating hardness is found closely related to the attrition rate under standard conditions and can be used to screen different powder/binder formulations. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
Granular gamma-Al2O3 support and 8 wt % CuO/gamma-Al2O3 catalyst were synthesized by a sol-gel granulation method. The pore structure, crush strength, hardness, and elasticity of these sol-gel-derived catalysts were studied and compared with similar commercial catalysts prepared by non-sol-gel methods. Alumina and CuO-coated alumina granular particles prepared by different methods have different macro- and microstructure. The sol-gel-derived granular gamma-alumina and CuO-coated gamma-alumina granular particles have a structure defined by compact packing of uniform, nanosized gamma-alumina crystallites. They are characterized by a more uniform pore size distribution and larger surface area as compared to similar commercial samples with a structure defined by packing of aggregates consisting of nonuniform gamma-alumina crystallites. Because of the differences in the macro- and microstructure, the sol-gel-derived granular samples offer higher crush strength and greater hardness than the commercial samples.
Resumo:
Nucleation is the first step in granulation where the powder and liquid first contact. Two types of nucleation in wet granulation processes are proposed. Drop controlled nucleation, where one drop forms one nucleus, occurs when drops hitting the powder surface do not overlap (low spray flux Psi(a)) and the drop must wet quickly into the bed (short drop penetration time t(p)). If either criterion is not met, powder mixing characteristics will dominate (mechanical dispersion regime). Granulation experiments were performed with lactose powder, water, PEG200, and 7% HPC solution in a 6 L and a 25 L mixer granulator. Size distributions were measured as the drop penetration time and spray flux were varied. At short penetration times, decreasing Psi(a) caused the nuclei distribution to become narrower. When drop penetration time was high, the nuclei size distribution was broad independent of changes in dimensionless spray flux. Nucleation regime maps were plotted for each set of experiments in each mixer as a function of the dimensionless distribution width delta. The nucleation regime map demonstrates the interaction between drop penetration time and spray flux in nucleation. The narrowest distribution consistently occurred at low spray flux and low penetration time, proving the existence of the drop controlled regime. The nucleation regime map provides a rational basis for design and scale-up of nucleation and wetting in wet granulation.
Resumo:
Particle flow patterns were investigated for wet granulation and dry powder mixing in ploughshare mixers using Positron Emission Particle Tracking (PEPT). In a 4-1 mixer, calcium carbonate with mean size 45 mum was granulated using a 50 wt.% solution of glycerol and water as binding fluid, and particle movement was followed using a 600-mum calcium hydroxy-phosphate tracer particle. In a 20-1 mixer, dry powder flow was studied using a 600-mum resin bead tracer particle to simulate the bulk polypropylene powder with mean size 600 mum. Important differences were seen between particle flow patterns for wet and dry systems. Particle speed relative to blade speed was lower in the wet system than in the dry system, with the ratios of average particle speed to blade tip speed for all experiments in the range 0.01-015. In the axial plane, the same particle motion was observed around each blade; this provides a significant advance for modelling flow in ploughshare mixers. For the future, a detailed understanding of the local velocity, acceleration and density variations around a plough blade will reveal the effects of flow patterns in granulating systems on the resultant distribution of granular product attributes such as size, density and strength. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
This study aimed to explore purchases of non-prescription medicines in New Zealand. Researchers were stationed for 5 days in 12 pharmacies throughout New Zealand during June and July of 1999. A brief questionnaire was administered, for each medicine purchased, to all available purchasers aged 16 years and over. At least partial data were collected from 2,597 medicine purchases (approximately 71.2% of medicine sales). Respiratory products comprised 42% of sales. Pharmacists were involved in 19.9% of medicine sales. Pharmacy staff featured in 62.2% of 792 influences on first-time purchases. This study tested a viable method for data collection and yielded valuable pharmaceutical marketing data.
Resumo:
The generic pharmaceutical value chain model has been employed to describe both the global pharmaceutical and biotechnology industries till now. This research investigates the organisational value chain in Australian biotechnology companies in order to assess the appropriateness of the pharmaceutical value chain to small-and medium-sized biotechnology companies. The main theme of the research is: Can a generic model of the organisational value chain be defined for the biotechnology industry? Emanating from the literature, two research propositions were developed. RP1: there are eight major definable elements/activities of the organisational value chain for the biotechnology industry. RP2: Coverage of the elements in the biotechnology value chain ranges from focused to broad. A multiple case study methodology was used to explore these propositions. To develop a number of case studies, data was collected from senior managers of small and medium Australian biotechnology companies using an interview instrument, as well as from publicly available documentation and through observation. The results were analysed using cross-case comparisons. The results showed that an aggregation of the value chains of each organisation can be reduced to these eight definable elements that constitute the biotechnology value chain: basic research, applied research, development, verification and validation, prototype development, clinical trials, manufacturing and marketing. However, the findings also indicate that these major elements of the value chain need to be further reduced into sub-activities or sub-tasks to cater for the unique differences between biotechnology companies. Generally, the findings were consistent with the literature. However, a wider sampling, including international biotechnology organisations should be studied. The major contribution of this research is in the development of a value chain model, including general sub-tasks, for the Australian biotechnology industry.
Resumo:
This paper reports the use of X-ray photoelectron spectroscopy (XPS) to investigate bisphosphonate (BP) adsorption onto plasma sprayed hydroxyapatite (HA) coatings commonly used for orthopaedic implants. BPs exhibit high binding affinity for the calcium present in HA and hence can be adsorbed onto HA-coated implants to exploit their beneficial properties for improved bone growth at the implant interface. A rigorous XPS analysis of pamidronate, a commonly used nitrogenous BP, adsorbed onto plasma sprayed HA-coated cobalt-chromium substrates has been carried out, aimed at: (a) confirming the adsorption of this BP onto HA; (b) studying the BP diffusion profile in the HA coating by employing the technique of XPS depth profiling; (c) confirming the bioactivity of the adsorbed BR XPS spectra of plasma sprayed HA-coated discs exposed to a 10 mM aqueous BP solution (pamidronate) for periods of 1, 2 and 24 h showed nitrogen and phosphorous photoelectron signals corresponding to the BP confirming its adsorption onto the HA substrate. XPS depth profiling of the 2 h BP-exposed HA discs showed penetration of the BP into the HA matrix to depths of at least 260 nm. The bioactivity of the adsorbed BP was confirmed by the observed inhibition of osteoclast (bone resorbing) cell activity. In comparison to the HA sample, the HA sample with adsorbed BP exhibited a 25-fold decrease in primary osteoclast cells. (c) 2006 Elsevier B.V. All rights reserved.