105 resultados para CLINICAL-SAMPLES
em University of Queensland eSpace - Australia
Resumo:
This study explored the relationship between coping, alcohol expectancies and drinking refusal self-efficacy in predicting drinking behaviour in both community and clinical samples. These variables were found to have differential effects in their association with frequency and volume of alcohol consumption across the two samples. Generally, drinking refusal self-efficacy was a more salient factor in relation to frequency and volume of community drinking, while coping and expectancies were more strongly associated with frequency of drinking sessions by problem drinkers. The interaction between expectancies and drinking refusal self-efficacy was related to volume of consumption in both groups, while coping and expectancies interacted in their association with frequency in the clinical group. The findings are discussed with regard to the different patterns of cognitive variables governing the decision to drink and the amount consumed in each drinking session, which may differentiate community and problem drinkers.
Resumo:
Cell culture and direct fluorescent antibody (DFA) assays have been traditionally used for the laboratory diagnosis of respiratory viral infections. Multiplex reverse transcriptase polymerase chain reaction (m-RT-PCR) is a sensitive, specific, and rapid method for detecting several DNIA and RNA viruses in a single specimen. We developed a m-RT-PCR assay that utilizes multiple virus-specific primer pairs in a single reaction mix combined with an enzyme-linked amplicon hybridization assay (ELAHA) using virus-specific probes targeting unique gene sequences for each virus. Using this m-RT-PCR-ELAHA, we examined the presence of seven respiratory viruses in 598 nasopharyngeal aspirate (NPA) samples from patients with suspected respiratory infection. The specificity of each assay was 100%. The sensitivity of the DFA was 79.7% and the combined DFA/culture amplified-DFA (CA-DFA) was 88.6% when compared to the m-RT-PCR-ELAHA. Of the 598 NPA specimens screened by m-RT-PCR-ELAHA, 3% were positive for adenovirus (ADM), 2% for influenza A (Flu A) virus, 0.3% for influenza B (Flu B) virus, 1% for parainfluenza type I virus (PIV1), 1% for parainfluenza type 2 virus (PIV2), 5.5% for parainfluenza type 3 virus (PIV3), and 21% for respiratory syncytial virus (RSV). The enhanced sensitivity, specificity, rapid result turnaround time and reduced expense of the m-RT-PCR-ELAHA compared to DFA and CA-DFA, suggests that this assay would be a significant improvement over traditional assays for the detection of respiratory viruses in a clinical laboratory.
Resumo:
Human polyomaviruses JC and BK may cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy and hemorrhagic cystitis. Molecular detection by PCR is recognized as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, a real-time PCR assay using the LightCycler platform was evaluated and compared to an in-house PCR assay using a conventional detection method. A total of 122 urine specimens were tested, and human polyomavirus was detected in 49 specimens (40%) by both conventional PCR and LightCycler PCR. The remaining 73 specimens (60%) were found negative by both assays. For 46 of the 49 positive specimens, LightCycler PCR and conventional PCR identified the same polyomavirus type. These samples included 30 samples with JC virus (JCV), 14 samples with BK virus (BKV), and 2 samples in which both viruses were detected. In the remaining three samples, both JCV and BKV were detected by the conventional assay, but only JCV was detected by the LightCycler assay. The results of this study show that the LightCycler PCR assay displays sensitivity and specificity similar to those of a conventional PCR assay. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid detection and differentiation of JCV and BKV in the clinical laboratory.
Resumo:
The present paper reviews the findings of 30 years of verbal/manual dual task studies, the method most commonly used to assess lateralization of speech production in non-clinical samples. Meta-analysis of 64 results revealed that both the type of manual task used and the nature of practice that is given influence the size of the laterality effect. A meta-analysis of 36 results examining the effect size of sex differences in estimate,, of lateralization of speech production indicated that males appear to show, slightly larger laterality effects than females. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Three Herpes Simplex Virus LightCycler polymerase chain reaction assays were compared for the detection of herpes simplex virus in 48 swab specimens. The assays comprised of one in-house assay and two commercial kits: the Artus HSV LC RealArt PCR kit and the Roche LightCycler HSV 1/2 Detection kit. On the whole, the three assays had comparable sensitivities. However, differentiation of herpes simplex virus types 1 and 2 by melting curve analysis was problematic in all assays. Overall, the results highlight the limitations of typing herpes simplex virus by melting curve analysis.
Resumo:
Objective To develop and validate specific, sensitive and rapid diagnostic tests using RT-PCR for the detection of Ross River virus (RRV), Kunjin virus (KV) and Murray Valley encephalitis virus (MVEV) infections in horses. Methods Primer sets based on nucleotide sequence encoding the envelope glycoprotein E2 of RRV and on the nonstructural protein 5 (NS5) of KV and MVEV were designed and used in single round PCRs to test for the respective viruses in infected cell cultures and, in the case of RRV, in samples of horse blood and synovial fluid. Results The primer pairs designed for each of the three viruses amplified a product of expected size from prototype viruses that were grown in cell culture. The identity of each of the products was confirmed by nucleotide sequencing indicating that in the context used the RT-PCRs were specific. RRV was detected in serums from 8 horses for which there were clinical signs consistent with RRV infection such that an acute-phase serum sample was taken and submitted for RRV serology testing. The RRV RT-PCR was analytically sensitive in that it was estimated to detect as little as 50 TCID50 of RRV per mL of serum and was specific in that the primer pairs did not amplify other products from the 8 serum samples. The RRV primers also detected virus in three independent mosquito pools known to contain RRV by virus isolation in cell culture. Samples from horses suspected to be infected with KV and MVEV were not available. Conclusion Despite much anecdotal and serological evidence for infection of horses with RRV actual infection and associated clinical disease are infrequently confirmed. The availability of a specific and analytically sensitive RT-PCR for the detection of RRV provides additional opportunities to confirm the presence of this virus in clinical samples. The RTPCR primers for the diagnosis of KV and MVEV infections were shown to be specific for cell culture grown viruses but the further validation of these tests requires the availability of appropriate clinical samples from infected horses.
Resumo:
The present study aimed to determine whether including a sensitive test of immediate and delayed recall would improve the diagnostic validity of the Rapid Screen of Concussion (RSC) in mild Traumatic Brain Injury (mTBI) versus orthopaedic clinical samples. Two studies were undertaken. In Study 1, the performance of 156 mTBI and 145 orthopaedic participants was analysed to identify the number of individuals who performed at ceiling on the verbal memory subtest of the RSC, as this test required immediate and delayed recall of only five words. A second aim was to determine the sensitivity and specificity levels of the RSC. Study 2 aimed to examine whether replacement of the verbal memory subtest with the 12-word Hopkins Verbal Learning Test (HVLT) could improve the sensitivity of the RSC in a new sample of 26 mTBI and 30 orthopaedic participants. Both studies showed that orthopaedic participants outperformed mTBI participants on each of the selected measures. Study 1 showed that 14% of mTBI participants performed at ceiling on the immediate and 21.2% on delayed recall test. Performance on the original battery yielded a sensitivity of 82%, specificity of 80% and overall correct classification of 81.5% participants. In Study 2, inclusion of the HVLT improved sensitivity to a level of 88.5%, decreased specificity to a level of 70% and resulted in an overall classification rate of 80%. It was concluded that although inclusion of the five-word subtest in the RSC can successfully distinguish concussed from non-concussed individuals, use of the HVLT in this protocol yields a more sensitive measure of subtle cognitive deficits following mTBI.
Resumo:
Mutations in the Plasmodium falciparum chloroquine resistance transporter (pfcrt) gene were examined to assess their associations with chloroquine resistance in clinical samples from Armopa (Papua) and Papua New Guinea. In Papua, two of the five pfcrt haplotypes found were new: SVIET from Armopa and CVIKT from an isolate in Timika. There was also a strong association (P < 0.0001) between the pfcrt 76T allele and chloroquine resistance in 50 samples. In Papua New Guinea, mutations in the pfcrt gene were observed in 15 isolates with chloroquine minimum inhibitory concentrations (MICs) of 16-64 pmol, while the remaining six isolates, which had a wild-type pfcrt gene at codon 76, had MICs of 2-8 pmol. These observations confirm that mutations at codon 76 in the pfcrt gene are present in both in vivo and in vitro cases of chloroquine resistance, and that detection of the pfcrt 76T allele could predict potential chloroquine treatment failures.
Resumo:
Human polyomaviruses JCV and BKV can cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy (PML) and haemorrhagic cystitis. Molecular detection by polymerase chain reaction (PCR) is recognised as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, we developed a PCR assay using a single primer pair to amplify a segment of the VP1 gene of JCV and BKV. An enzyme linked amplicon hybridisation assay (ELAHA) using species-specific biotinylated oligonucleotide probes was used to differentiate between JCV and BKV. This assay (VP1-PCR-ELAHA) was evaluated and compared to a PCR assay targeting the human polyomavirus T antigen gene (pol-PCR). DNA sequencing was used to confirm the polyomavirus species identified by the VP1-PCR-ELAHA and to determine the subtype of each JCV isolate. A total of 297 urine specimens were tested and human polyomavirus was detected in 105 specimens (35.4%) by both PCR assays. The differentiation of JCV and BKV by the VP1-PCR-ELAHA showed good agreement with the results of DNA sequencing. Further, DNA sequencing of the JCV positive specimens showed the most prevalent JCV subtype in our cohort was 2a (27%) followed by 1b (20%), 1a (15%), 2c (14%), 4 (14%) and 2b (10%). The results of this study show that the VP1-PCR-ELAHA is a sensitive, specific and rapid method for detecting and differentiating human polyomaviruses JC and BK and is highly suitable for routine use in the clinical laboratory. (C) 2004 Wiley-Liss, Inc.
Resumo:
The Roche Cobas Amplicor system is widely used for the detection of Neisseria gonorrhoeae but is known to cross react with some commensal Neisseria spp. Therefore, a confirmatory test is required. The most common target for confirmatory tests is the cppB gene of N. gonorrhoeae. However, the cppB gene is also present in other Neisseria spp. and is absent in some N. gonorrhoeae isolates. As a result, laboratories targeting this gene run the risk of obtaining both false-positive and false-negative results. In the study presented here, a newly developed N. gonorrhoeae LightCycler assay (NGpapLC) targeting the N. gonorrhoeae porA pseudogene was tested. The NGpapLC assay was used to test 282 clinical samples, and the results were compared to those obtained using a testing algorithm combining the Cobas Amplicor System (Roche Diagnostics, Sydney, Australia) and an in-house LightCycler assay targeting the cppB gene (cppB-LC). In addition, the specificity of the NGpapLC assay was investigated by testing a broad panel of bacteria including isolates of several Neisseria spp. The NGpapLC assay proved to have comparable clinical sensitivity to the cppB-LC assay. In addition; testing of the bacterial panel showed the NGpapLC assay to be highly specific for N. gonorrhoeae DNA. The results of this study show the NGpapLC assay is a suitable alternative to the cppB-LC assay for confirmation of N. gonorrhoeae-positive results obtained with Cobas Amplicor.