38 resultados para Bubble Detachment
em University of Queensland eSpace - Australia
Resumo:
A hydraulic jump is characterised by strong energy dissipation and air entrainment. In the present study, new air-water flow measurements were performed in hydraulic jumps with partially-developed flow conditions in relatively large-size facilities with phase-detection probes. The experiments were conducted with identical Froude numbers, but a range of Reynolds numbers and relative channel widths. The results showed drastic scale effects at small Reynolds numbers in terms of void fraction and bubble count rate distributions. The void fraction distributions implied comparatively greater detrainment at low Reynolds numbers leading to a lesser overall aeration of the jump roller, while dimensionless bubble count rates were drastically lower especially in the mixing layer. The experimental results suggested also that the relative channel width had little effect on the air-water flow properties for identical inflow Froude and Reynolds numbers.
Resumo:
In an open channel, the transition from super- to sub-critical flow is a flow singularity (the hydraulic jump) characterised by a sharp rise in free-surface elevation, strong turbulence and air entrainment in the roller. A key feature of the hydraulic jump flow is the strong free-surface aeration and air-water flow turbulence. In the present study, similar experiments were conducted with identical inflow Froude numbers Fr1 using a geometric scaling ratio of 2:1. The results of the Froude-similar experiments showed some drastic scale effects in the smaller hydraulic jumps in terms of void fraction, bubble count rate and bubble chord time distributions. Void fraction distributions implied comparatively greater detrainment at low Reynolds numbers yielding some lesser aeration of the jump roller. The dimensionless bubble count rates were significantly lower in the smaller channel, especially in the mixing layer. The bubble chord time distributions were quantitatively close in both channels, and they were not scaled according to a Froude similitude. Simply the hydraulic jump remains a fascinating two-phase flow motion that is still poorly understood.
Resumo:
Interaction forces between protein inclusion bodies and an air bubble have been quantified using an atomic force microscope (AFM). The inclusion bodies were attached to the AFM tip by covalent bonds. Interaction forces measured in various buffer concentrations varied from 9.7 nN to 25.3 nN (+/- 4-11%) depending on pH. Hydrophobic forces provide a stronger contribution to overall interaction force than electrostatic double layer forces. It also appears that the ionic strength affects the interaction force in a complex way that cannot be directly predicted by DLVO theory. The effects of pH are significantly stronger for the inclusion body compared to the air bubble. This study provides fundamental information that will subsequently facilitate the rational design of flotation recovery system for inclusion bodies. It has also demonstrated the potential of AFM to facilitate the design of such processes from a practical viewpoint.
Resumo:
A new device has been developed to directly measure the bubble loading of particle-bubble aggregates in industrial flotation machines, both mechanical flotation cells as well as flotation column cells. The bubble loading of aggregates allows for in-depth analysis of the operating performance of a flotation machine in terms of both pulp/collection zone and froth zone performance. This paper presents the methodology along with an example showing the excellent reproducibility of the device and an analysis of different operating conditions of the device itself. (C) 2004 Elsevier B.V All rights reserved.
Resumo:
The anterior adhesive mechanism was studied for Merizocotyle icopae (Monogenea: Monocotylidae). Adult anterior apertures can open and close. In addition, duct endings terminating within the apertures are everted or retracted depending on the stage of attachment. Adhesive in adults is synthesized from all 3 secretory types (rod-shaped, small and large spheroidal bodies) found within anterior apertures. All exit together and undergo mixing to produce the adhesive matrix, a process that depletes duct contents. A greater number of ducts carrying rod-shaped bodies is depleted than ducts containing spheroidal bodies which changes the ratio of secretory types present on detachment. Detachment involves elongation of duct endings and secretion of additional matrix as the worm pulls away from the substrate. The change in secretory type ratio putatively modifies the properties of the secreted matrix enabling detachment. Only after detachment do ducts refill. During attachment, individual secretory bodies undergo morphological changes. The larval and adult adhesive matrix differs. Anterior adhesive in oncomiracidia does not show fibres with banding whereas banded fibres comprise a large part of adult adhesive. The data Suggest that this is the result of adult spheroidal secretions modifying the way in which the adult adhesive matrix forms.
Resumo:
The anterior adhesion and detachment mechanisms observed for Neoheterocotyle rhinobatidis and Troglocephalus rhinobatidis (Monogenea: Monocotylidae) appear similar to those observed for the two other monopisthocotylean monogenean species with anterior apertures for which published data are available. This supports the theory that monogeneans with apertures may utilise a common mechanism. Adult anterior apertures can open and close and duct endings can evert during the adhesion phase and retract during detachment and searching behaviour. The adhesive is comprised of two secretory types, rod-shaped and spheroidal bodies, found within anterior apertures. These exit together and undergo mixing to produce the adhesive matrix in which elongate membranes from rod-shaped bodies are seen intermixed with a granular electron-dense matrix. The morphology of the adhesive matrix differs from that found for some other monogenean taxa. Anterior detachment by these monocotylids appears to involve a depletion of rod-shaped bodies in ducts and mechanical withdrawal of the anterior end.
Resumo:
This paper presents a comparative study how reactor configuration, sludge loading and air flowrate affect flow regimes, hydrodynamics, floc size distribution and sludge solids-liquid separation properties. Three reactor configurations were studied in bench scale activated sludge bubble column reactor (BCR), air-lift reactor (ALR) and aerated stirred reactor (ASR). The ASR demonstrated the highest capacity of gas holdup and resistance, and homogeneity in flow regimes and shearing forces, resulting in producing large numbers of small and compact floes. The fluid dynamics in the ALR created regularly directed recirculation forces to enhance the gas holdup and sludge flocculation. The BCR distributed a high turbulent flow regime and non-homogeneity in gas holdup and mixing, and generated large numbers of larger and looser floes. The sludge size distributions, compressibility and settleability were significantly influenced by the reactor configurations associated with the flow regimes and hydrodynamics.
Resumo:
Froth recovery measurements have been conducted in both the presence (three-phase froth) and absence (two-phase froth) of particles of different contact angles in a specially modified laboratory flotation column. Increasing the particle hydrophobicity increased the flow rate of particles entering the froth, while the recovery of particles across the froth phase itself also increased for particle contact angles to 63 and at all vertical heights of the froth column. However, a further increase in the contact angle to 69 resulted in lower particle recovery across the froth phase. The reduced froth recovery for particles of 69 contact angle was linked to significant bubble coalescence within the froth phase. The reduced froth recovery occurred uniformly across the entire particle size range, and was, presumably, a result of particle detachment from coalescing bubbles. Water flow rates across the froth phase also varied with particle contact angle. The general trend was a decrease in the concentrate flow rate of water with increasing particle contact angle. An inverse relationship between water flow rate and bubble radius was also observed, possibly allowing prediction of water flow rate from bubble size measurements in the froth. Comparison of the froth structure, defined by bubble size, gas hold-up and bubble layer thickness, for two- and three-phase froths, at the same frother concentration, showed there was a relationship between water flow rate and froth structure. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
A technique for determining the recovery of attached particles across the froth phase in flotation that relies on measuring the rate at which bubble-particle aggregates enter the froth is used to investigate the selectivity of attached particles across the froth phase. Combining these measurements with those of other techniques for determining the froth recovery of attached particles provides an insight into the different sub-processes of particle rejection in the froth phase. The results of experiments conducted in a 3 m(3) Outokumpu tank cell show that the detachment of particles from aggregates in the froth phase occurs largely at the pulp-froth interface. In particular it is shown that the pulp-froth interface selectively detaches particles from aggregates according to their physical attributes. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A technique for determining the recovery of attached particles across the froth phase in flotation that relies on measuring the rate at which bubble-particle aggregates enter the froth is used to investigate the selectivity of attached particles across the froth phase. Combining these measurements with those of other techniques for determining the froth recovery of attached particles provides an insight into the different subprocesses of particle rejection in the froth phase. The results of experiments conducted in a 3 m3 Outokumpu tank cell show that the detachment of particles from aggregates in the froth phase occurs largely at the pulp-froth interface. In particular it is shown that the pulp-froth interface selectively detaches particles from aggregates according to their physical attributes.