10 resultados para Boots and shoes
em University of Queensland eSpace - Australia
Resumo:
Objective. To compare the efficacy of two forms of eye care (hypromellose and Lacri-Lube combination vs polyethylene/Cling wrap covers) for intensive care patients. Design. Randomised-controlled trial. Setting. University affiliated, tertiary referral hospital. Patients and participants. One hundred ten patients with a reduced or absent blink reflex were followed through until they regained consciousness, were discharged from the facility during study enrolment, died or developed a positive corneal ulcer or eye infection. Interventions. All patients received standard eye cleansing every 2 h. In addition to this, group one (n=60) received a treatment combining hypromellose drops and Lacri-Lube (HL) to each eye every 2 h. Group two (n=50) had polyethylene covers only placed over the eye to create a moisture chamber. Measurements and results. Corneal ulceration was determined using corneal fluorescein stains and mobile slit lamp evaluation, performed daily. No patients had corneal ulceration in the polyethylene cover group, but 4 patients had corneal ulceration in the HL group. Conclusions. Polyethylene covers are as effective as HL in reducing the incidence of corneal damage in intensive care patients.
Resumo:
The manner in which elements of clinical history, physical examination and investigations influence subjectively assessed illness severity and outcome prediction is poorly understood. This study investigates the relationship between clinician and objectively assessed illness severity and the factors influencing clinician's diagnostic confidence and illness severity rating for ventilated patients with suspected pneumonia in the intensive care unit (ICU). A prospective study of fourteen ICUs included all ventilated admissions with a clinical diagnosis of pneumonia. Data collection included pneumonia type - community-acquired (CAP), hospital-acquired (HAP) and ventilator-associated (VAP), clinician determined illness severity (CDIS), diagnostic methods, clinical diagnostic confidence (CDC), microbiological isolates and antibiotic use. For 476 episodes of pneumonia (48% CAP, 24% HAP, 28% VAP), CDC was greatest for CAP (64% CAP, 50% HAP and 49% VAP, P < 0.01) or when pneumonia was considered life-threatening (84% high CDC, 13% medium CDC and 3% low CDC, P < 0.001). Life-threatening pneumonia was predicted by worsening gas exchange (OR 4.8, CI 95% 2.3-10.2, P < 0.001), clinical signs of consolidation (OR 2.0, CI 95% 1.2-3.2, P < 0.01) and the Sepsis-Related Organ Failure Assessment (SOFA) Score (OR 1.1, CI 95% 1.1-1.2, P < 0.001). Diagnostic confidence increased with CDIS (OR 163, CI 95% 8.4-31.4, P < 0.001), definite pathogen isolation (OR 3.3, CI 95% 2.0-5.6) and clinical signs of consolidation (OR 2.1, CI 95% 1.3-3.3, P = 0.001). Although the CDIS, SOFA Score and the Simplified Acute Physiologic Score (SAPS II) were all associated with mortality, the SAPS II Score was the best predictor of mortality (P = 0.02). Diagnostic confidence for pneumonia is moderate but increases with more classical presentations. A small set of clinical parameters influence subjective assessment. Objective assessment using SAPS II Scoring is a better predictor of mortality.
Resumo:
Passive tilting increases ventilation in healthy subjects; however, controversy surrounds the proposed mechanism. This study is aimed to evaluate the possible mechanism for changes to ventilation following passive head-up tilt (HUT) and active standing by comparison of a range of ventilatory, metabolic and mechanical parameters. Ventilatory parameters (V (T), V (E), V (E)/VO2, V (E)/VCO2, f and PetCO(2)), functional residual capacity (FRC), respiratory mechanics with impulse oscillometry; oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in 20 healthy male subjects whilst supine, following HUT to 70 degrees and unsupported standing. Data were analysed using a linear mixed model. HUT to 70 degrees from supine increased minute ventilation (V (E)) (P < 0.001), tidal volume (V (T)) (P=0.001), ventilatory equivalent for O-2 (V (E)/VO2) (P=0.020) and the ventilatory equivalent for CO2 (V (E)/VCO2) (P < 0.001) with no change in f (P=0.488). HUT also increased FRC (P < 0.001) and respiratory system reactance (X5Hz) (P < 0.001) with reduced respiratory system resistance (R5Hz) (P=0.004) and end-tidal carbon dioxide (PetCO(2)) (P < 0.001) compared to supine. Standing increased V (E) (P < 0.001), V (T) (P < 0.001) and V (E)/VCO2 (P=0.020) with no change in respiratory rate (f) (P=0.065), V (E)/VO2 (P=0.543). Similar changes in FRC (P < 0.001), R5Hz (P=0.013), X5Hz (P < 0.001) and PetCO(2) (P < 0.001) compared to HUT were found. In contrast to HUT, standing increased VO2 (P=0.002) and VCO2 (P=0.048). The greater increase in V (E) in standing compared to HUT appears to be related to increased VO2 and VCO2 associated with increased muscle activity in the unsupported standing position. This has implications for exercise prescription and rehabilitation of critically ill patients who have reduced cardiovascular and respiratory reserve.
Resumo:
This study of ventilated patients investigated pneumonia risk factors and outcome predictors in 476 episodes of pneumonia (48% community-acquired pneumonia, 24% hospital-acquired pneumonia, 28% ventilator-associated pneumonia) using a prospective survey in 14 intensive care units within Australia and New Zealand. For community acquired pneumonia, mortality increased with immunosuppression (OR 5.32, CI 95% 1.58-17.99, P < 0. 01), clinical signs of consolidation (OR 2.43, CI 95% 1.09-5.44, P = 0. 03) and Sepsis-Related Organ Failure Assessment (SOFA) scores (OR 1.19, CI 95% 1.08-1.30, P < 0. 001) but improved if appropriate antibiotic changes were made within three days of intensive care unit admission (OR 0.42, CI 95% 0.20-0.86, P = 0.02). For hospital-acquired pneumonia, immunosuppression (OR 6.98, CI 95% 1.16-42.2, P = 0.03) and non-metastatic cancer (OR 3.78, CI 95% 1.20-11.93, P = 0.02) were the principal mortality predictors. Alcoholism (OR 7.80, CI 95% 1.20-1750, P < 0.001), high SOFA scores (OR 1.44, CI 95% 1.20-1.75, P = 0.001) and the isolation of high risk organisms including Pseudomonas aeruginosa, Acinetobacter spp, Stenotrophomonas spp and methicillin resistant Staphylococcus aureus (OR 4.79, CI 95% 1.43-16.03, P = 0.01), were associated with increased mortality in ventilator-associated pneumonia. The use of non-invasive ventilation was independently protective against mortality for patients with community-acquired and hospital-acquired pneumonia (OR 0.35, CI 95% 0.18-0.68, P = 0.002). Mortality was similar for patients requiting both invasive and non-invasive ventilation and non-invasive ventilation alone (21% compared with 20% respectively, P = 0.56). Pneumonia risks and mortality predictors in Australian and New Zealand ICUs vary with pneumonia type. A history of alcoholism is a major risk factor for mortality in ventilator-associated pneumonia, greater in magnitude than the mortality effect of immunosuppression in hospital-acquired pneumonia or community-acquired pneumonia. Non-invasive ventilation is associated with reduced ICU mortality. Clinical signs of consolidation worsen, while rationalising antibiotic therapy within three days of ICU admission improves mortality for community-acquired pneumonia patients.
Resumo:
This study of ventilated patients investigated current clinical practice in 476 episodes of pneumonia (48% community-acquired pneumonia, 24% hospital-acquired pneumonia, 28% ventilator-associated pneumonia) using a prospective survey in 14 intensive care units (ICUs) within Australia and New Zealand. Diagnostic methods and confidence, disease severity, microbiology and antibiotic use were assessed. All pneumonia types had similar mortality (community-acquired pneumonia 33%, hospital-acquired pneumonia 37% and ventilator-associated pneumonia 24%, P = 0.15) with no inter-hospital differences (P = 0.08-0.91). Bronchoscopy was performed in 26%, its use predicted by admission hospital (one tertiary: OR 9.98, CI 95% 5.11-19.49, P < 0.001; one regional: OR 629, CI 95% 3.24-12.20, P < 0.001), clinical signs of consolidation (OR 3.72, CI 95% 2.09-662, P < 0.001) and diagnostic confidence (OR 2.19, CI 95% 1.29-3.72, P = 0.004). Bronchoscopy did not predict outcome (P = 0.11) or appropriate antibiotic selection (P = 0.69). Inappropriate antibiotic prescription was similar for all pneumonia types (11-13%, P = 0.12) and hospitals (0-16%, P = 0.25). Blood cultures were taken in 51% of cases. For community-acquired pneumonia, 70% received a third generation cephalosporin and 65% a macrolide. Third generation cephalosporins were less frequently used for mild infections (OR 0.38, CI 95% 0.16-0.90, P = 0.03), hospital-acquired pneumonia (OR 0.40, CI 95% 0.23-0.72, P < 0.01), ventilator-associated pneumonia (OR 0.04, CI 95% 0.02-0.13, P < 0.001), suspected aspiration (OR 0.20, CI 95% 0.04-0.92, P = 0.04), in one regional (OR 0.26, CI 95% 0.07-0.97, P = 0.05) and one tertiary hospital (OR 0.14, CI 95% 0.03-0.73, P = 0.02) but were more commonly used in older patients (OR 1.02, CI 95% 1.01-1.03, P = 0.01). There is practice variability in bronchoscopy and antibiotic use for pneumonia in Australian and New Zealand ICUs without significant impact on patient outcome, as the prevalence of inappropriate antibiotic prescription is low. There are opportunities for improving microbiological diagnostic work-up for isolation of aetiological pathogens.
Resumo:
Objective: To compare the incidence of ventilator-associated pneumonia (VAP) in patients ventilated in intensive care by means of circuits humidified with a hygroscopic heat-and-moisture exchanger with a bacterial viral filter (HME) or hot-water humidification with a heater wire in both inspiratory and expiratory circuit limbs (DHW) or the inspiratory limb only (SHW). Design: A prospective, randomized trial. Setting: A metropolitan teaching hospital's general intensive care unit. Patients: Three hundred eighty-one patients requiring a minimum period of mechanical ventilation of 48 hrs. Interventions: Patients were randomized to humidification with use of an HME (n = 190), SHW (n = 94), or DHW (n = 97). Measurements and Main Results. Study end points were VAP diagnosed on the basis of Clinical Pulmonary Infection Score (CPIS) (1), HME resistance after 24 hrs of use, endotracheal tube resistance, and HME use per patient. VAP occurred with similar frequency in all groups (13%, HME; 14%, DHW; 10%, SHW; p = 0.61) and was predicted only by current smoking (adjusted odds ratio [AOR], 2.1; 95% confidence interval [CI], 1.1-3.9; p =.03) and ventilation days (AOR, 1.05; 95% Cl, 1.0-1.2; p =.001); VAP was less likely for patients with an admission diagnosis of pneumonia (AOR, 0.40; 95% Cl, 0.4-0.2; p =.04). HME resistance after 24 hrs of use measured at a gas flow of 50 L/min was 0.9 cm H2O (0.4-2.9). Endotracheal tube resistance was similar for all three groups (16-19 cm H2O min/L; p =.2), as were suction frequency, secretion thickness, and blood on suctioning (p =.32, p =.06, and p =.34, respectively). The HME use per patient per day was 1.13. Conclusions: Humidification technique does not influence either VAP incidence or secretion characteristics, but HMEs may have air-flow resistance higher than manufacturer specifications after 24 hrs of use.
Resumo:
A case of aspergillus tracheobronchitis following influenza A infection in an immunocompetent 35 year old woman is described that required prolonged mechanical ventilation for airways obstruction. Treatment included liposomal amphotericin, inhaled amphotericin, gamma interferon and GM-CSF. Liposomal amphotericin therapy was associated with reversible hepatosplenomegaly. Inhaled corticosteroids with continued antifungal therapy were used for the management of severe recurrent airway obstruction. After a prolonged course of treatment she survived with fixed airways obstruction unresponsive to corticosteroids.