Resumo:
Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
The evolution of event time and size statistics in two heterogeneous cellular automaton models of earthquake behavior are studied and compared to the evolution of these quantities during observed periods of accelerating seismic energy release Drier to large earthquakes. The two automata have different nearest neighbor laws, one of which produces self-organized critical (SOC) behavior (PSD model) and the other which produces quasi-periodic large events (crack model). In the PSD model periods of accelerating energy release before large events are rare. In the crack model, many large events are preceded by periods of accelerating energy release. When compared to randomized event catalogs, accelerating energy release before large events occurs more often than random in the crack model but less often than random in the PSD model; it is easier to tell the crack and PSD model results apart from each other than to tell either model apart from a random catalog. The evolution of event sizes during the accelerating energy release sequences in all models is compared to that of observed sequences. The accelerating energy release sequences in the crack model consist of an increase in the rate of events of all sizes, consistent with observations from a small number of natural cases, however inconsistent with a larger number of cases in which there is an increase in the rate of only moderate-sized events. On average, no increase in the rate of events of any size is seen before large events in the PSD model.
Resumo:
The assumption in analytical solutions for flow from surface and buried point sources of an average water content, (θ) over bar, behind the wetting front is examined. Some recent work has shown that this assumption fitted some field data well. Here we calculated (θ) over bar using a steady state solution based on the work by Raats [1971] and an exponential dependence of the diffusivity upon the water content. This is compared with a constant value of (θ) over bar calculated from an assumption of a hydraulic conductivity at the wetting front of 1 mm day(-1) and the water content at saturation. This comparison was made for a wide range of soils. The constant (θ) over bar generally underestimated (θ) over bar at small wetted radii and overestimated (θ) over bar at large radii. The crossover point between under and overestimation changed with both soil properties and flow rate. The largest variance occurred for coarser texture soils at low-flow rates. At high-flow rates in finer-textured soils the use of a constant (θ) over bar results in underestimation of the time for the wetting front to reach a particular radius. The value of (θ) over bar is related to the time at which the wetting front reaches a given radius. In coarse-textured soils the use of a constant value of (θ) over bar can result in an error of the time when the wetting front reaches a particular radius, as large as 80% at low-flow rates and large radii.
Resumo:
Using the classical twin design, this study investigates the influence of genetic factors on the large phenotypic variance in inspection time (IT), and whether the well established IT-IQ association can be explained by a common genetic factor. Three hundred ninety pairs of twins (184 monozygotic, MZ; 206 dizygotic, DZ) with a mean age of 16 years participated, and 49 pairs returned approximately 3 months, later for retesting. As in many IT studies, the pi figure stimulus was used and IT was estimated from the cumulative normal ogive. IT ranged from 39.4 to 774.1 ms (159 +/- 110.1 ms) with faster ITs (by an average of 26.9 ms) found in the retest session from which a reliability of .69 was estimated. Full-scale IQ (FIQ) was assessed by the Multidimensional Aptitude Battery (MAB) and ranged from 79 to 145 (111 +/- 13). The phenotypic association between IT and FIQ was confirmed (- .35) and bivariate results showed that a common genetic factor accounted for 36% of the variance in IT and 32% of the variance in FIQ. The maximum likelihood estimate of the genetic correlation was - .63. When performance and verbal IQ (PIQ & VIQ) were analysed with IT, a stronger phenotypic and genetic relationship was found between PIQ and IT than with VIQ. A large part of the IT variance (64%) was accounted for by a unique environmental factor. Further genetic factors were needed to explain the remaining variance in IQ with a small component of unique environmental variance present. The separability of a shared genetic factor influencing IT and IQ from the total genetic variance in IQ suggests that IT affects a specific subcomponent of intelligence rather than a generalised efficiency. (C) 2001 Elsevier Science Inc. All rights reserved.
Resumo:
Background. Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. Methods. One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (eg, severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal Concordance between modalities was expressed at kappa Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS video-tape was used to store video data The reading time and storage costs for each modality were compared Results. Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thicken ing (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P < .001). Compressed digital studies had an average size of 60 <plus/minus> 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). Conclusion. Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.
Resumo:
Forecasting category or industry sales is a vital component of a company's planning and control activities. Sales for most mature durable product categories are dominated by replacement purchases. Previous sales models which explicitly incorporate a component of sales due to replacement assume there is an age distribution for replacements of existing units which remains constant over time. However, there is evidence that changes in factors such as product reliability/durability, price, repair costs, scrapping values, styling and economic conditions will result in changes in the mean replacement age of units. This paper develops a model for such time-varying replacement behaviour and empirically tests it in the Australian automotive industry. Both longitudinal census data and the empirical analysis of the replacement sales model confirm that there has been a substantial increase in the average aggregate replacement age for motor vehicles over the past 20 years. Further, much of this variation could be explained by real price increases and a linear temporal trend. Consequently, the time-varying model significantly outperformed previous models both in terms of fitting and forecasting the sales data. Copyright (C) 2001 John Wiley & Sons, Ltd.
Resumo:
Background: Paediatric dento-alveolar trauma is a common event. Delays in treatment can have adverse effects on long term outcomes and the aim of this study was to quantify the treatment delays in paediatric dento-alveolar trauma in a tertiary referral hospital. Methods: All cases of paediatric dento-alveolar trauma over a two-year period from July 2000 to June 2002 were identified and the charts were reviewed retrospectively. All children presenting the emergency department with dento-alveolar trauma within 48 hours of injury during the time period were included. Results: Forty-three patients were identified. The average age was 5.51 years, though there was a bias towards one and two year olds. Males were injured 1.5 times more frequently than females. There was an average delay of 9.6 hours between injury and treatment for all patients. Transit time from outside practitioners to hospital and waiting times in hospital made up the greatest delays. Children injured an average of 2.37 teeth and only 14 per cent were uncomplicated crown fractures. Conclusions: Children who present to children's hospitals for treatment of dento-alveolar trauma have more severe injuries than those treated elsewhere. They have large but potentially reducible delays between injury and treatment.
Resumo:
In this paper we propose a new identification method based on the residual white noise autoregressive criterion (Pukkila et al. , 1990) to select the order of VARMA structures. Results from extensive simulation experiments based on different model structures with varying number of observations and number of component series are used to demonstrate the performance of this new procedure. We also use economic and business data to compare the model structures selected by this order selection method with those identified in other published studies.
Resumo:
OBJECTIVES We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). BACKGROUND Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. METHODS Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. RESULTS The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. CONCLUSIONS Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice. (C) 2004 by the American College of Cardiology Foundation.
Resumo:
Objective: To explore the relationship between family average income (FAI; an index of socio-economic status) and body mass index (BMI; a widely used, inexpensive indicator of weight status) above the healthy weight range in a region of Mainland China. Design: Population-based cross-sectional study, conducted between October 1999 and March 2000 on a sample of regular local residents aged 35 years or older who were selected by random cluster sampling. Setting: Forty-five administrative villages selected from three urban districts and two rural counties of Nanjing municipality, Mainland China, with a regional population of 5.6 million. Subjects: In total, 29 340 subjects participated; 67.7% from urban and 32.3% from rural areas; 49.8% male and 50.2% female. The response rate among eligible participants was 90.1%. Results: The proportion of participants classified as overweight was 30.5%, while 7.8% were identified as obese. After adjusting for possible confounding variables (age, gender, area of residence, educational level, occupational and leisure-time physical activity, daily vegetable consumption and frequency of red meat intake), urban participants were more likely to be overweight or obese relative to their rural counterparts, more women than men were obese, and participants in the lowest FAI tertile were the least likely to be above the healthy weight range. Conclusions: The proportion of adults with BMI above the healthy weight range was positively related to having a higher socio-economic status (indexed by FAI) in a regional Chinese population.
Resumo:
Objective: To assess the value of cusum analysis in hospital bed management. Design: Comparative analysis of medical patient flows, bed occupancy, and emergency department admission rates and access block over 2 years. Setting: Internal Medicine Services and Emergency Department in a teaching hospital. Interventions: Improvements in bed use and changes in the level of available beds. Main outcome measures: Average length of stay; percentage occupancy of available beds; number of patients waiting more than 8 hours for admission (access block); number of medical patients occupying beds in non-medical wards; and number of elective surgical admissions. Results: Cusum analysis provided a simple means of revealing important trends in patient flows that were not obvious in conventional time-series data. This prompted improvements in bed use that resulted in a decrease of 9500 occupied bed-days over a year. Unfortunately and unexpectedly, after some initial improvement, the levels of access block, medical ward congestion and elective surgical admissions all then deteriorated significantly. This was probably caused by excessive bed closures in response to the initial improvement in bed use. Conclusion: Cusum analysis is a useful technique for the early detection of significant changes in patient flows and bed use, and in determining the appropriate number of beds required for a given rate of patient flow.
Resumo:
Objectives: Left atrial (LA) volume (LAV) is a prognostically important biomarker for diastolic dysfunction, but its reproducibility on repeated testing is not well defined. LA assessment with 3-dimensional. (3D) echocardiography (3DE) has been validated against magnetic resonance imaging, and we sought to assess whether this was superior to existing measurements for sequential echocardiographic follow-up. Methods: Patients (n = 100; 81 men; age 56 +/- 14 years) presenting for LA evaluation were studied with M-mode (MM) echocardiography, 2-dimensional (2D) echocardiography, and 3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 hour without alteration of hemodynamics or therapy. In all, 20 patients were studied for interobserver and intraobserver variation. LAVs were calculated by using M-mode diameter and planimetered atrial area in the apical. 4-chamber view to calculate an assumed sphere, as were prolate ellipsoid, Simpson's biplane, and biplane area-length methods. All were compared with 3DE. Results: The average LAV was 72 +/- 27 mL by 3DE. There was significant underestimation of LAV by M-mode (35 +/- 20 mL, r = 0.66, P < .01). The 3DE and various 2D echocardiographic techniques were well correlated: LA planimetry (85 +/- 38 mL, r = 0.77, P < .01), prolate ellipsoid (73 +/- 36 mL, r = 0.73, P = .04), area-length (64 +/- 30 mL, r = 0.74, P < .01), and Simpson's biplane (69 +/- 31 mL, r = 0.78, P = .06). Test-retest variation for 3DE was most favorable (r = 0.98, P < .01), with the prolate ellipsoid method showing most variation. Interobserver agreement between measurements was best for 3DE (r = 0.99, P < .01), with M-mode the worst (r = 0.89, P < .01). Intraobserver results were similar to interobserver, the best correlation for 3DE (r = 0.99, P < .01), with LA planimetry the worst (r = 0.91, P < .01). Conclusions. The 2D measurements correlate closely with 3DE. Follow-up assessment in daily practice appears feasible and reliable with both 2D and 3D approaches.
Resumo:
The estimation of a concentration-dependent diffusion coefficient in a drying process is known as an inverse coefficient problem. The solution is sought wherein the space-average concentration is known as function of time (mass loss monitoring). The problem is stated as the minimization of a functional and gradient-based algorithms are used to solve it. Many numerical and experimental examples that demonstrate the effectiveness of the proposed approach are presented. Thin slab drying was carried out in an isothermal drying chamber built in our laboratory. The diffusion coefficients of fructose obtained with the present method are compared with existing literature results.