11 resultados para Atrophic maxilla - Fixed prosthesis

em University of Queensland eSpace - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

How does the classical phase-space structure for a composite system relate to the entanglement characteristics of the corresponding quantum system? We demonstrate how the entanglement in nonlinear bipartite systems can be associated with a fixed-point bifurcation in the classical dynamics. Using the example of coupled giant spins we show that when a fixed point undergoes a supercritical pitchfork bifurcation, the corresponding quantum state-the ground state-achieves its maximum amount of entanglement near the critical point. We conjecture that this will be a generic feature of systems whose classical limit exhibits such a bifurcation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion. The new Provox(R) NID (TM) non- indwelling voice prosthesis investigated in this study provides a good option for laryngectomized patients using non- indwelling voice prostheses and can potentially improve safety and increase patients' satisfaction with their voice and speech. Objective. To investigate the feasibility of and patient satisfaction with the Provox NID non- indwelling voice prosthesis. Material and methods. Pre- and post- study questionnaires were used to evaluate the patients' former voice prosthesis and the Provox NID voice prosthesis. In addition, measurements of pull- out force, maximum phonation time and loudness were made for both voice prostheses. In vitro measurements of airflow characteristics were also made. Following a 6- week trial, all patients provided feedback on the new voice prosthesis and the results were used to further improve the Provox NID. This final version of the new voice prosthesis was subsequently trialled and evaluated by 10 patients 6 months later. Results. Overall results showed that patient satisfaction with the Provox NID non- indwelling voice prosthesis was favourable. The pull- out force for the new prosthesis was significantly higher than that for the formerly used prosthesis and its aerodynamic characteristics were better.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A restricted maximum likelihood analysis applied to an animal model showed no significant differences (P > 0.05) in pH value of the longissimus dorsi measured at 24 h post-mortem (pH24) between high and low lines of Large White pigs selected over 4 years for post-weaning growth rate on restricted feeding. Genetic and phenotypic correlations between pH24 and production and carcass traits were estimated using all performance testing records combined with the pH24 measurements (5.05–7.02) on slaughtered animals. The estimate of heritability for pH24 was moderate (0.29 ± 0.18). Genetic correlations between pH24 and production or carcass composition traits, except for ultrasonic backfat (UBF), were not significantly different from zero. UBF had a moderate, positive genetic correlation with pH24 (0.24 ± 0.33). These estimates of genetic correlations affirmed that selection for increased growth rate on restricted feeding is likely to result in limited changes in pH24 and pork quality since the selection does not put a high emphasis on reduced fatness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of naphthalene-2-sulfonic acid (2-NSA) adsorption by granular activated carbon (GAC) were measured and the relationships between adsorption, desorption, bioavailability and biodegradation assessed. The conventional Langmuir model fitted the experimental sorption isotherm data and introduced 2-NSA degrading bacteria, established on the surface of the GAC, did not interfere with adsorption. The potential value of GAC as a microbial support in the aerobic degradation of 2-NSA by Arthrobacter globiformis and Comamonas testosteroni was investigated. Using both virgin and microbially colonised GAC, adsorption removed 2-NSA from the liquid phase up to its saturation capacity of 140 mg/g GAC within 48 h. However, between 83.2% and 93.3% of the adsorbed 2-NSA was bioavailable to both bacterial species as a source of carbon for growth. In comparison to the non-inoculated GAC, the combination of rapid adsorption and biodegradation increased the amount (by 70–93%) of 2-NSA removal from the influent phase as well as the bed-life of the GAC (from 40 to >120 d). A microbially conditioned GAC fixed-bed reactor containing 15 g GAC removed 100% 2-NSA (100 mg/l) from tannery wastewater at an empty bed contact time of 22 min for a minimum of 120 d without the need for GAC reconditioning or replacement. This suggests that small volume GAC bioreactors could be used for tannery wastewater recycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the outcomes associated with two differing right unilateral (RUL) electroconvulsive therapy (ECT) dosing protocols: 2-3X seizure threshold (2-3X ST) and fixed high dose (FHD) at 353 mC. A retrospective chart review was performed to compare patient outcomes during the implementation of two different dosing protocols: 2-3X ST from October 2000 to May 2001 and FHD from June 2001 to February 2002. A total of 56 patients received ECT under the 2-3X ST protocol, and 46 received ECT under the FHD protocol. In total, 13.6% of patients receiving ECT according to the 2-3X ST protocol received more than 12 ECT, whereas none of the FHD group received more than 12 ECT. The mean number of ECT per treatment course reduced significantly from 7.6 to 5.7 following the switch from the 2-3X ST protocol to the FHD protocol. There were no significant differences between the two groups in the incidence of adverse cognitive effects. ECT practitioners adhered to the 2-3X ST protocol for only 51.8% of ECT courses, with protocol adherence improving to 87% following introduction of the FHD protocol. Although this naturalistic retrospective chart survey had significant methodological limitations, it found that practitioners are more likely to correctly adhere to a fixed dose protocol, therefore, increasing its 'real world' effectiveness in comparison to titrated suprathreshold dosing techniques. The FHD protocol was associated with shorter courses of ECT than the 2-3X ST protocol, with no significant difference between the two protocols in clinically discernable adverse cognitive effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we extend the state-contingent production approach to principal–agent problems to the case where the state space is an atomless continuum. The approach is modelled on the treatment of optimal tax problems. The central observation is that, under reasonable conditions, the optimal contract may involve a fixed wage with a bonus for above-normal performance. This is analogous to the phenomenon of "bunching" at the bottom in the optimal tax literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra wideband (UWB) radar has been extensively investigated both theoretically and practically for the identification buried artifacts. Ground probe radar (GPR) concentrates on the identification of lightly buried land mines, unexploded ordnance (UXO) and archeological targets. The same technology is proposed in a similar context for the rapid identification of in vivo implanted metallic prostheses. The technique is based on resonance based target identification and the paper investigates UWB scattering from a metallic hip prosthesis in free space as a first step in the identification process.

Relevância:

20.00% 20.00%

Publicador: