8 resultados para Aggregates, mean volume

em University of Queensland eSpace - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Australian Aborigines are experiencing epidemic proportions of renal disease, marked by albuminuria and, variably, hematuria. They also have high rates of low birth weight, which have been associated with lower kidney volumes and higher blood pressures. The authors evaluated relationships between kidney volume, blood pressure, albuminuria, and hematuria in 1 homogeneous group. Methods Forty-three percent (672 of 1,560) of the population in a remote coastal Australian Aboriginal community aged 4.4 to 72.1 years participated in the study. Results: Kidney size correlated closely with body size. Systolic blood pressure (SBP) was correlated inversely with kidney length and kidney volume, after adjusting for age, sex, and body surface area (BSA); a 1-cm increase in mean kidney length was associated with a 2.2-mm Hg decrease in SBP, and a 10-mL increase in mean kidney volume was associated with a 0.6-mm Hg decrease in SBP (P = 0.001). Mean kidney volume explained 10% of the variance in SBP in a multivariate model containing age, sex, and BSA. In addition to higher SBP, adults who had the lowest quartiles of kidney volume also had the highest levels of overt albuminuria (P = 0.044). Conclusion: Smaller kidneys predispose to higher blood pressures and albuminuria in this population. The lower volumes possibly represent kidneys with reduced nephron numbers, which might be related to an adverse intrauterine environment. Susceptibility to renal disease could be a direct consequence of reduced nephron numbers; the higher blood pressures with which they are associated could also contribute to, as well as derive from, this association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The degree of volume depletion in severe malaria is currently unknown, although knowledge of fluid compartment volumes can guide therapy. To assist management of severely ill children, and to test the hypothesis that volume changes in fluid compartments reflect disease severity, we measured body compartment volumes in Gabonese children with malaria. Methods and Findings Total body water volume (TBW) and extracellular water volume (ECW) were estimated in children with severe or moderate malaria and in convalescence by tracer dilution with heavy water and bromide, respectively. Intracellular water volume (ICW) was derived from these parameters. Bioelectrical impedance analysis estimates of TBW and ECW were calibrated and bioelectrical impedance analysis measurements were taken daily against dilution methods, until discharge. Sixteen children had severe and 19 moderate malaria. Severe childhood malaria was associated with depletion of TBW (mean [SD] of 37 [33] ml/kg, or 6.7% [6.0%]) relative to measurement at discharge. This is defined as mild dehydration in other conditions. ECW measurements were normal on admission in children with severe malaria and did not rise in the first few days of admission. Volumes in different compartments (TBW, ECW, and ICW) were not related to hyperlactataemia or other clinical and laboratory markers of disease severity. Moderate malaria was not associated with a depletion of TBW. Conclusions Significant hypovolaemia does not exacerbate complications of severe or moderate malaria. As rapid rehydration of children with malaria may have risks, we suggest that fluid replacement regimens should aim to correct fluid losses over 12-24 h.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Qualitative interpretation of myocardial contrast echocardiography (MCE) improves the accuracy of wall-motion analysis for assessment of coronary artery disease (CAD). We examined the feasibility and accuracy of quantitative MCE for diagnosis of CAD. Methods: Dipyridamole/exercise stress MCE (destruction-replenishment protocol with real-time imaging) was performed in 90 patients undergoing quantitative coronary angiography, 48 of whom had significant (> 50%) stenoses. MCE was repeated with exercise alone in 18 patients. Myocardial blood flow (A*beta) was obtained from blood volume (A) and time to refill (beta). Results: Quantification of flow reserve was feasible in 88%. The mean A*beta reserve in the anterior wall was significantly impaired for patients with left anterior descending coronary artery disease (n = 28) compared with those with no disease (1.6 +/- 1.2 vs; 4.0 +/- 2.5, P <=.001). This reflected impaired beta reserve, with no difference in the A reserve. Applying a receiver operating characteristic curve derived cutoff of 2.0 for A*beta reserve, quantitative MCE was 76% sensitive and 71% specific for the diagnosis of significant left anterior descending coronary artery stenosis. Posterior circulation results were similar, with 78% sensitivity and 59% specificity for detection of posterior CAD. Overall, quantitative MCE was similarly sensitive to qualitative approach for diagnosis of CAD (88% vs 93%), but with lower specificity (52% vs 65%, P =.07). In 18 patients restudied with pure exercise stress, the mean myocardial blood flow reserve was less than after combined stress (2.1 +/- 1.6 vs 3.7 +/- 1.9, P =.01). Conclusion: Quantitative MCE is feasible for the diagnosis of CAD with dipyridamole/exercise stress. Dipyridamole prolongs postexercise hyperemia, augmenting the degree of hyperemia at the time of imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to examine the effects of different methods of measuring training volume, controlled in different ways, on selected variables that reflect acute neuromuscular responses. Eighteen resistance-trained males performed three fatiguing protocols of dynamic constant external resistance exercise, involving elbow flexors, that manipulated either time-under-tension (TUT) or volume load (VL), defined as the product of training load and repetitions. Protocol A provided a standard for TUT and VL. Protocol B involved the same VL as Protocol A but only 40% concentric TUT; Protocol C was equated to Protocol A for TUT but only involved 50% VL. Fatigue was assessed by changes in maximum voluntary isometric contraction (MVIC), interpolated doublet (ID), muscle twitch characteristics (peak twitch, time to peak twitch, 0.5 relaxation time, and mean rates of force development and twitch relaxation). All protocols produced significant changes (P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to investigate the number of glomerular profiles that are required for accurate estimates of mean profile area in a renal biopsy series. Slides from 384 renal biopsies from one center were reviewed. They contained a median of seven glomerular profiles or of four profiles without sclerosis. Profile areas were measured using stereologic point counting. The true individual mean for each biopsy was calculated and the true population mean for groups of biopsies derived. Individual and population random sample means then were calculated from a random sampling of profiles in each biopsy and were compared with true means for the same biopsies. The effect on the true population means of the entire group of biopsies was also assessed, as the minimum number of glomerular profiles that were required for inclusion was changed. In a single biopsy, random sampling of >= 10 profiles without exclusions and of eight profiles or more without sclerosis reliably estimated the true mean areas. In a group of 30 biopsies, random sampling of five or more glomeruli per biopsy reliably estimated the true population mean. In the aggregate series, inclusion of all 384 biopsies produced the most robust true population mean; the reliability of the estimates decreased as the numbers of eligible biopsies diminished with increasing requisite minimum numbers of profiles per biopsy. We conclude that, while >= 10 profiles might be needed for reliable area estimates in a single biopsy, far fewer profiles per biopsy can suffice when groups of biopsies are studied. In analyses of groups of biopsies, all available biopsies should be used without consideration of the number of glomerular profiles in each. Stipulation of a specific minimum number of glomeruli in each biopsy for inclusion reduces the power of analyses because fewer biopsies are available for evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is well known that resistance training improves muscle strength in older adults and may enhance or preserve functional performance. However, it is unclear if the volume of work undertaken in the elderly alters the response in functional performance. PURPOSE: To investigate the effect of a high- versus low-volume resistance training program on functional performance in older adults. METHODS: Thirty-two healthy men and women aged 65-78 years were randomly assigned to either a single-set (SS, n = 16) or 3-set (MS, n = 16) progressive resistance training program for 20 weeks. Groups trained 2 days per week using machine weights at 8 repetitions maximum (8-RM) for 7 upper and lower body exercises. Muscle strength was assessed by the 1-RM and functional performance by a battery of tests (repeated chair rise, usual and fast 6-m walk, 6-m backwards walk, floor rise to standing, stair climb, and 400-m walk time). RESULTS: Twenty-eight subjects completed the study. There was no difference between groups at baseline in muscle strength or functional performance. Whole body muscle strength significantly increased in both groups with greater gains in the 3-set group (MS 32.9 ± 3.1%; SS 18.6 ± 2.7%, mean ± SE; P < 0.01). Significant improvement (time effect, P < 0.01) occurred for both groups in the chair rise (MS 13.6 ± 3.2%; SS 10.2 ± 3.0%), 6-m backwards walk (MS 14.9 ± 3.3%; SS 14.3 ± 4.2%), stair climb (MS 6.4 ± 2.8%; SS 7.7 ± 3.1%) and 400-m walk (MS 7.4 ± 1.4%; SS 3.9 ± 1.2%). There were no interaction (group × time) effects for functional performance and no differences by sex. CONCLUSION: Resistance training that utilizes either a singleset or 3-set regimen may significantly and similarly improve functional performance in community-dwelling older adults. Enhancement of functional performance may prolong independence and improve quality of life. ©2004The American College of Sports Medicine