27 resultados para ALPINE LAKE
em University of Queensland eSpace - Australia
Resumo:
Observational data collected in the Lake Tekapo hydro catchment of the Southern Alps in New Zealand are used to analyse the wind and temperature fields in the alpine lake basin during summertime fair weather conditions. Measurements from surface stations, pilot balloon and tethersonde soundings, Doppler sodar and an instrumented light aircraft provide evidence of multi-scale interacting wind systems, ranging from microscale slope winds to mesoscale coast-to-basin flows. Thermal forcing of the winds occurred due to differential heating as a consequence of orography and heterogeneous surface features, which is quantified by heat budget and pressure field analysis. The daytime vertical temperature structure was characterised by distinct layering. Features of particular interest are the formation of thermal internal boundary layers due to the lake-land discontinuity and the development of elevated mixed layers. The latter were generated by advective heating from the basin and valley sidewalls by slope winds and by a superimposed valley wind blowing from the basin over Lake Tekapo and up the tributary Godley Valley. Daytime heating in the basin and its tributary valleys caused the development of a strong horizontal temperature gradient between the basin atmosphere and that over the surrounding landscape, and hence the development of a mesoscale heat low over the basin. After noon, air from outside the basin started flowing over mountain saddles into the basin causing cooling in the lowest layers, whereas at ridge top height the horizontal air temperature gradient between inside and outside the basin continued to increase. In the early evening, a more massive intrusion of cold air caused rapid cooling and a transition to a rather uniform slightly stable stratification up to about 2000 m agl. The onset time of this rapid cooling varied about 1-2 h between observation sites and was probably triggered by the decay of up-slope winds inside the basin, which previously countered the intrusion of air over the surrounding ridges. The intrusion of air from outside the basin continued until about mid-night, when a northerly mountain wind from the Godley Valley became dominant. The results illustrate the extreme complexity that can be caused by the operation of thermal forcing processes at a wide range of spatial scales.
Resumo:
High-resolution numerical model simulations have been used to study the local and mesoscale thermal circulations in an Alpine lake basin. The lake (87 km(2)) is situated in the Southern Alps, New Zealand and is located in a glacially excavated rock basin surrounded by mountain ranges that reach 3000 m in height. The mesoscale model used (RAMS) is a three-dimensional non-hydrostatic model with a level 2.5 turbulence closure scheme. The model demonstrates that thermal forcing at local (within the basin) and regional (coast-to-basin inflow) scales drive the observed boundary-layer airflow in the lake basin during clear anticyclonic summertime conditions. The results show that the lake can modify (perturb) both the local and regional wind systems. Following sunrise, local thermal circulations dominate, including a lake breeze component that becomes embedded within the background valley wind system. This results in a more divergent flow in the basin extending across the lake shoreline. However, a closed lake breeze circulation is neither observed nor modelled. Modelling results indicate that in the latter part of the day when the mesoscale (coast-to-basin) inflow occurs, the relatively cold pool of lake air in the basin can cause the intrusion to decouple from the surface. Measured data provide qualitative and quantitative support for the model results.
Resumo:
This paper presents observations of summertime anti-winds monitored under ideal conditions in the Lake Tekapo hydro-catchment situated in the central Southern Alps, New Zealand. Onset and cessation of anti-winds was observed to coincide with the change in phase of the surface limbs of thermally generated valley and mountain winds under settled anti-cyclonic conditions. Anti-winds were best developed in the early morning before surface heating and associated convective mixing of the valley atmosphere began to mask the boundaries between the surface based limb of the mountain-valley wind and the corresponding anti-wind. By mid-day, the anti-valley wind exceeded the height of the surrounding ridgeline and became embedded in the topographically channeled gradient wind. Observations presented here have both theoretical and applied implications with regard to the development of thermally generated wind systems in deep alpine valleys, and their role in the dispersion of air pollution.
Resumo:
Vinyl window to daybed alcove, bedroom pavilion, South-West elevation.
Resumo:
Vinyl window to bath house pavilion, South-West elevation.
Resumo:
As seen from West, looking towards front of main pavilion. Standard roller doors to clerestory.
Resumo:
Bedroom pavilion, South-East elevation. Day bed alcove on left.
Resumo:
As seen from back of bedroom pavilion, looking towards main pavilion. Day bed alcove to bedroom in foreground.
Resumo:
Bath house and bedroom pavilions, with outdoor seating area in foreground.
Resumo:
South-West elevation of main pavilion - living, kitchen, dining and study/guest areas.
Resumo:
As seen from outdoor seating area. Pivoting vent on left and day bed alcove on right. Standard roller doors to clerestory.
Resumo:
South-West elevation. Paved seating area in foreground.
Resumo:
Link to bedroom pavilion on right; roof of main pavilion on left.
Resumo:
Bedroom pavilion on left, bath house pavilion centre and main pavilion on right.