16 resultados para 3D imaging

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Langerhans cells (LCs) can be targeted with DNA-coated gold micro-projectiles ("Gene Gun") to induce potent cellular and humoral immune responses. It is likely that the relative volumetric distribution of LCs and keratinocytes within the epidermis impacts on the efficacy of Gene Gun immunization protocols. This study quantified the three-dimensional (3D) distribution of LCs and keratinocytes in the mouse skin model with a near-infrared multiphoton laser-scanning microscope (NIR-MPLSM). Stratum corneum (SC) and viable epidermal thickness measured with MPLSM was found in close agreement with conventional histology. LCs were located in the vertical plane at a mean depth of 14.9 mum, less than 3 mum above the dermo-epidermal boundary and with a normal histogram distribution. This likely corresponds to the fact that LCs reside in the suprabasal layer (stratum germinativum). The nuclear volume of keratinocytes was found to be approximately 1.4 times larger than that of resident LCs (88.6 mum3). Importantly, the ratio of LCs to keratinocytes in mouse ear skin (1:15) is more than three times higher than that reported for human breast skin (1:53). Accordingly, cross-presentation may be more significant in clinical Gene Gun applications than in pre-clinical mouse studies. These interspecies differences should be considered in pre-clinical trials using mouse models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: It is generally assumed that fascial defects in the rectovaginal septum are the result of childbirth. However, rectoceles do occur in women who have never delivered vaginally. Aims: To determine the incidence of rectocele in a cohort of asymptomatic, young nulliparous women. Methods: Observational cohort study on 178 nulliparous caucasian women (aged 18-24) recruited for a twin study of pelvic floor dysfunction. All women were interviewed and examined by translabial ultrasound, supine and after voiding. In 52 women, 3D imaging was obtained and 171 datasets were complete and available for analysis. Ultrasound findings were reviewed for rectovaginal septal integrity by an assessor blinded against interview and demographic data for rectovaginal septal integrity. Results: A discontinuity of the anterior rectal wall with extrusion of rectal mucosa or contents (depth of ! 10 mm) was observed in 21/171 (12%). The depth of this herniation ranged from 10 to 25 mm and was filled with stool (n = 10) or rectal mucosa (n = 11). Defects were associated with a higher BMI (P = 0.049), with the complaint of constipation (P = 0.049) and non-significantly with straining at stool (P = 0.09). Descent of the ampulla to beyond the level of the symphysis pubis without fascial defect, that is, significant perineal relaxation, was observed in 23/171 (13%). Conclusions: Twelve percent of 171 young nulligravid caucasian women showed a defect of the rectovaginal septum. Associations were observed with higher body mass index and a history of constipation. It is hypothesised that in some women defects of the rectovaginal septum and perineal hypermobility may be congenital in nature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings. especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present the correction of the geometric distortion measured in the clinical magnetic resonance imaging (MRI) systems reported in the preceding paper (Part 1) using a 3D method based on the phantom-mapped geometric distortion data. This method allows the correction to be made on phantom images acquired without or with the vendor correction applied. With the vendor's 2D correction applied, the method corrects for both the residual geometric distortion still present in the plane in which the correction method was applied (the axial plane) and the uncorrected geometric distortion along the axis non-nal to the plane. The evaluation of the effectiveness of the correction using this new method was carried out through analyzing the residual geometric distortion in the corrected phantom images. The results show that the new method can restore the distorted images in 3D nearly to perfection. For all the MRI systems investigated, the mean absolute deviations in the positions of the control points (along x-, y- and z-axes) measured on the corrected phantom images were all less than 0.2 mm. The maximum absolute deviations were all below similar to0.8 mm. As expected, the correction of the phantom images acquired with the vendor's correction applied in the axial plane performed equally well. Both the geometric distortion still present in the axial plane after applying the vendor's correction and the uncorrected distortion along the z-axis have all been restored. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, a 3D phantom that can provide a comprehensive and accurate measurement of the geometric distortion in MRI has been developed. Using this phantom, a full assessment of the geometric distortion in a number of clinical MRI systems (GE and Siemens) has been carried out and detailed results are presented in this paper. As expected, the main source of geometric distortion in modern superconducting MRI systems arises from the gradient field nonlinearity. Significantly large distortions with maximum absolute geometric errors ranged between 10 and 25 mm within a volume of 240 x 240 x 240 mm(3) were observed when imaging with the new generation of gradient systems that employs shorter coils. By comparison, the geometric distortion was much less in the older-generation gradient systems. With the vendor's correction method, the geometric distortion measured was significantly reduced but only within the plane in which these 2D correction methods were applied. Distortion along the axis normal to the plane was, as expected, virtually unchanged. Two-dimensional correction methods are a convenient approach and in principle they are the only methods that can be applied to correct geometric distortion in a single slice or in multiple noncontiguous slices. However, these methods only provide an incomplete solution to the problem and their value can be significantly reduced if the distortion along the normal of the correction plane is not small. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ingress of water into copolymers of 2-hydroxyethyl methacrylate (HEMA) and tetrahydrofurfuryl methacrylate (THFMA) loaded with either one of two model drugs, ie vitamin B-12 or aspirin, was studied at 310 K using three-dimensional nuclear magnetic resonance (3D NMR) imaging. The poly(HEMA) was loaded with 5 wt% of the drugs. From the imaging profiles it was observed that incorporation of vitamin B-12 into the polymers rich in HEMA resulted in crack formation at the interface between the rubbery region and the glassy core on sorption of water, although these cracks were 'healed' behind the diffusion front. However, for the copolymers with low HEMA contents and for those containing aspirin, no evidence for similar crack formation was found. For the copolymers loaded with 5 wt% of aspirin or vitamin B-12 the values of the water diffusion coefficients, determined by curve-fitting the relative water concentration profiles from magnetic resonance imaging (MRI) measurements, were found to be smaller than those obtained from a mass uptake study. (C) 2004 Society of Chemical Industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Left ventricular (LV) volumes have important prognostic implications in patients with chronic ischemic heart disease. We sought to examine the accuracy and reproducibility of real-time 3D echo (RT-3DE) compared to TI-201 single photon emission computed tomography (SPECT) and cardiac magnetic resonance imaging (MRI). Thirty (n = 30) patients (age 62±9 years, 23 men) with chronic ischemic heart disease underwent LV volume assessment with RT-3DE, SPECT, and MRI. Ano vel semi-automated border detection algorithmwas used by RT-3DE. End diastolic volumes (EDV) and end systolic volumes (ESV) measured by RT3DE and SPECT were compared to MRI as the standard of reference. RT-3DE and SPECT volumes showed excellent correlation with MRI (Table). Both RT- 3DE and SPECT underestimated LV volumes compared to MRI (ESV, SPECT 74±58 ml versus RT-3DE 95±48 ml versus MRI 96±54 ml); (EDV, SPECT 121±61 ml versus RT-3DE 169±61 ml versus MRI 179±56 ml). The degree of ESV underestimation with RT-3DE was not significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deformable models are a highly accurate and flexible approach to segmenting structures in medical images. The primary drawback of deformable models is that they are sensitive to initialisation, with accurate and robust results often requiring initialisation close to the true object in the image. Automatically obtaining a good initialisation is problematic for many structures in the body. The cartilages of the knee are a thin elastic material that cover the ends of the bone, absorbing shock and allowing smooth movement. The degeneration of these cartilages characterize the progression of osteoarthritis. The state of the art in the segmentation of the cartilage are 2D semi-automated algorithms. These algorithms require significant time and supervison by a clinical expert, so the development of an automatic segmentation algorithm for the cartilages is an important clinical goal. In this paper we present an approach towards this goal that allows us to automatically providing a good initialisation for deformable models of the patella cartilage, by utilising the strong spatial relationship of the cartilage to the underlying bone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of 3D visualisation of digital information is a recent phenomenon. It relies on users understanding 3D perspectival spaces. Questions about the universal access of such spaces has been debated since its inception in the European Renaissance. Perspective has since become a strong cultural influence in Western visual communication. Perspective imaging assists the process of experimenting by the sketching or modelling of ideas. In particular, the recent 3D modelling of an essentially non-dimensional Cyber-space raises questions of how we think about information in general. While alternate methods clearly exist they are rarely explored within the 3D paradigm (such as Chinese isometry). This paper seeks to generate further discussion on the historical background of perspective and its role in underpinning this emergent field. © 2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the creation of 3D statistical shape models of the knee bones and their use to embed information into a segmentation system for MRIs of the knee. We propose utilising the strong spatial relationship between the cartilages and the bones in the knee by embedding this information into the created models. This information can then be used to automate the initialisation of segmentation algorithms for the cartilages. The approach used to automatically generate the 3D statistical shape models of the bones is based on the point distribution model optimisation framework of Davies. Our implementation of this scheme uses a parameterized surface extraction algorithm, which is used as the basis for the optimisation scheme that automatically creates the 3D statistical shape models. The current approach is illustrated by generating 3D statistical shape models of the patella, tibia and femoral bones from a segmented database of the knee. The use of these models to embed spatial relationship information to aid in the automation of segmentation algorithms for the cartilages is then illustrated.