7 resultados para 3 dB CP bandwidth

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A self-matched printed hemispherical helical antenna for potential use in global positioning system receivers is introduced. Unlike wired hemispherical helical antennas, its printed form renders it a much more stable and endurable structure and also easier for fabrication. The optimized antenna shows an impedance bandwidth of 6%, a 3-dB axial ratio bandwidth of 6%-7%, a return loss greater than 20 dB, and a gain of about 9 dB at the center frequency. The patterns of the antenna show a larger mainlobe in the upper half space with relatively small backlobes. Both theoretical and experimental results will be presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of transmitter and receiver array configurations on the stray-light and diffraction-caused crosstalk in free-space optical interconnects was investigated. The optical system simulation software (Code V) is used to simulate both the stray-light and diffraction-caused crosstalk. Experimentally measured, spectrally-resolved, near-field images of VCSEL higher order modes were used as extended sources in our simulation model. In addition, we have included the electrical and optical noise in our analysis to give more accurate overall performance of the FSOI system. Our results show that by changing the square lattice geometry to a hexagonal configuration, we obtain an overall signal-to-noise ratio improvement of 3 dB. Furthermore, system density is increased by up to 4 channels/mm2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the effect of transmitter and receiver array configurations on the stray-light and diffraction-caused crosstalk in free-space optical interconnects. The optical system simulation software (Code V) is used to simulate both the stray-light and diffraction-caused crosstalk. Experimentally measured, spectrally-resolved, near-field images of VCSEL higher order modes were used as extended sources in our simulation model. Our results show that by changing the square lattice geometry to a hexagonal configuration, we obtain the reduction in the stray-light crosstalk of up to 9 dB and an overall signal-to-noise ratio improvement of 3 dB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of an ultra-wideband planar tapered slot antenna for use in a circular cylindrical microwave imaging system is pre-sented. The antenna was designed assuming high dielectric substrate material Rogers RT6010LM to achieve its compact size. The developed antenna element (50 X 50 mm(2)) features a 10-dB return loss bandwidth from 2.75 GHz to more than 11 GHz. The gain of the antenna is between 3.5 and 9.4 dBi over the 3-10 GHz band. The experimental tests showed that the manufactured antenna element supports transmission of narrow pulses with negligible distortions, as required in the microwave imaging system. (c) 2006 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method for the design of ultra-wideband antennas in planar format is presented. This method is demonstrated for a high-dielectric-constant substrate material, which allows for a considerable antenna size reduction. Simulations are performed using Ansoft's High-Frequency Structure Simulator (HFSS) for antennas assuming Du-Pont951 (epsilon(r) = 7.8) and RT6010LM (epsilon(r) = 10.2) substrates. For the 1-mm-thick DuPont951, the designed antenna with 22 X 28 nun dimensions features a 10-dB return-loss band width front 2.7 GHz to more than 15 GHz. For the 0.64-mm-thick RT6010LM a 20 X 26 nun antenna exhibits a 10-dB return loss bandwidth from 3.1 to 15 GHz. Both antennas feature nearly omnidirectional properties across the whole 10-dB return-loss bandwidth. The validity of the presented UWB antenna design strategy is confirmed by measurements performed on a prototype developed on RT6010LM substrate. (c) 2006 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Simple design formulas for designing ultra wideband (UWB) antennas in the form of complementary planar monopoles are described and their validity is tested using full electromagnetic wave simulations and measurements. Assuming dielectric substrate with relative permittivity of 10.2, the designed antennas feature a small size of 13 mmtimes26 mm. They exhibit a 10 dB return loss bandwidth from 3 to more than 15 GHz accompanied by near omnidirectional characteristics and good radiation efficiency throughout this band