123 resultados para fixed path methods
Resumo:
In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
The aim of this study was to compare accumulated oxygen deficit data derived using two different exercise protocols with the aim of producing a less time-consuming test specifically for use with athletes. Six road and four track male endurance cyclists performed two series of cycle ergometer tests. The first series involved five 10 min sub-maximal cycle exercise bouts, a (V) over dotO(2peak) test and a 115% (V) over dotO(2peak) test. Data from these tests were used to estimate the accumulated oxygen deficit according to the calculations of Medbo et al. (1988). In the second series of tests, participants performed a 15 min incremental cycle ergometer test followed, 2 min later, by a 2 min variable resistance test in which they completed as much work as possible while pedalling at a constant rate. Analysis revealed that the accumulated oxygen deficit calculated from the first series of tests was higher (P< 0.02) than that calculated from the second series: 52.3 +/- 11.7 and 43.9 +/- 6.4 ml . kg(-1), respectively (mean +/- s). Other significant differences between the two protocols were observed for (V) over dot O-2peak, total work and maximal heart rate; all were higher during the modified protocol (P
Resumo:
Understanding the mechanism of liquid-phase evaporation in a three-phase fixed-bed reactor is of practical importance, because the reaction heat is usually 7-10 times the vaporization heat of the liquid components. Evaporation, especially the liquid dryout, can largely influence the reactor performance and even safety. To predict the vanishing condition of the liquid phase, Raoult's law was applied as a preliminary approach, with the liquid vanishing temperature defined based on a liquid flow rate of zero. While providing correct trends, Raoult's law exhibits some limitation in explaining the temperature profile in the reactor. To comprehensively understand the whole process of liquid evaporation, a set of experiments on inlet temperature, catalyst activity, liquid flow rate, gas flow rate, and operation pressure were carried out. A liquid-region length-predicting equation is suggested based on these experiments and the principle of heat balance.