183 resultados para body measurements
Resumo:
BACKGROUND: Because subcutaneous and splanchnic oxygenation indices are sensitive indicators of evolving hemorrhagic shock and adequacy of resuscitation, we postulated that these indices might have an equivalent role in the monitoring of severely burned patients. This observational study was undertaken to examine changes in tissue oxygenation indices during burn resuscitation. METHODS: Seven patients with major burns (54 +/- 21% total body surface area) were studied during the first 36 hours of fluid resuscitation. Silastic tubing was placed in the subcutaneous tissue just beneath both normal skin and deep partial thickness burn. Fiberoptic sensors inserted into the tubing measured subcutaneous oxygen and carbon dioxide tensions in the burnt skin (PO2scb and PCO2scb) and normal skin (PO2scn and PCO2scn) continuously. Gastric intramucosal pH (pHi) and the mucosal CO2 (PCO2m) gap were calculated using gastric tonometers. Mean arterial pressure, arterial pH, lactate, and pHi measurements were obtained for 36 hours. RESULTS: There were no significant differences in mean arterial pressure, arterial pH, or lactate concentrations throughout the study period, whereas indices of tissue oxygenation showed deterioration: pHi decreased from 7.2 +/- 0.1 to 6.7 +/- 0.3 (p = 0.06), the PCO2m gap increased from 12 +/- 17 to 108 +/- 123 mm Hg (p < 0.01), PO2scn decreased from 112 +/- 18 to 50 +/- 11 mm Hg (p < 0.01), PO2scb decreased from 62 +/- 23 to 29 +/- 16 mm Hg (p < 0.01), PCO2scn increased from 42 +/- 4 to 46 +/- 10 mm Hg (p = 0.2), and PCO2scb increased from 42 +/- 10 to 52 +/- 5 mm Hg (p = 0.05). CONCLUSION: Despite adequate global indices of tissue perfusion after 36 hours of resuscitation, tissue monitoring indicated significant deterioration in the splanchnic circulation and in the normal and burnt skin.
Resumo:
This paper describes a rainfall simulator developed for field and laboratory studies that gives great flexibility in plot size covered, that is highly portable and able to be used on steep slopes, and that is economical in its water use. The simulator uses Veejet 80100 nozzles mounted on a manifold, with the nozzles controlled to sweep to and from across a plot width of 1.5 m. Effective rainfall intensity is controlled by the frequency with which the nozzles sweep. Spatial uniformity of rainfall on the plots is high, with coefficients of variation (CV) on the body of the plot being 8-10%. Use of the simulator for erosion and infiltration measurements is discussed.
Resumo:
This study investigated the change in body composition in 36 cancer outpatients receiving radiotherapy to the head and neck area (mean age: 63 ± 15 years) randomised to receive either nutrition intervention (NI; n=15) or usual care (UC; n=21). Body weight and composition were measured at the commencement of radiotherapy and 3 months later. The UC group lost significantly more weight; mean decrease = 4.3 kg, than the NI group: mean decrease = 1.1 kg (t(30)=-2.5, p=0.019). Fat-free mass loss was significantly higher in the UC group with a mean loss of 2.2 kg versus 0.3 kg in the NI group (t(30)=- 2.3, p=0.029). Body composition as measured by foot-to-foot bioelectrical impedance analysis provides more information than weight alone and can allow for tailoring of NI.
Resumo:
Objective: To compare measurements of sleeping metabolic rate (SMR) in infancy with predicted basal metabolic rate (BMR) estimated by the equations of Schofield. Methods: Some 104 serial measurements of SMR by indirect calorimetry were performed in 43 healthy infants at 1.5, 3, 6, 9 and 12 months of age. Predicted BMR was calculated using the weight only (BMR-wo) and weight and height (BMR-wh) equations of Schofield for 0-3-y-olds. Measured SMR values were compared with both predictive values by means of the Bland-Altman statistical test. Results: The mean measured SMR was 1.48 MJ/day. The mean predicted BMR values were 1.66 and 1.47 MJ/day for the weight only and weight and height equations, respectively. The Bland-Altman analysis showed that BMR-wo equation on average overestimated SMR by 0.18 MJ/day (11%) and the BMR-wh equation underestimated SMR by 0.01 MJ/day (1%). However the 95% limits of agreement were wide: - 0.64 to - 0.28MJ/day (28%) for the former equation and - 0.39 to +0.41 MJ/day (27%) for the latter equation. Moreover there was a significant correlation between the mean of the measured and predicted metabolic rate and the difference between them. Conclusions: The wide variation seen in the difference between measured and predicted metabolic rate and the bias probably with age indicates there is a need to measure actual metabolic rate for individual clinical care in this age group.
Resumo:
Objectives: To assess the accuracy of reporting from both a diet history and food record and identify some of the characteristics of more accurate reporters in a group of healthy adult volunteers for an energy balance study. Design: Prospective measurements in free-living people. Setting: Wollongong, Australia. Subjects: Fifteen healthy volunteers (seven male, eight female; aged 22 -59 y; body mass index (BMI) 19 - 33 kg/m(2)) from the local community in the city of Wollongong, Australia. Interventions: Measurement of energy intake via diet history interview and 7 day food records, total energy expenditure by the doubly labelled water technique over 14 days, physical activity by questionnaire, and body fat by dual-energy X-ray absorptiometry. Results: Increased misreporting of energy intake was associated with increased energy expenditure (r = 0.90, P < 0.0001, diet history; r(s)=0.79, P=0.0005, food records) but was not associated with age, sex, BMI or body fat. Range in number of recorded dinner foods correlated positively with energy expenditure (r(s)=0.63, P=0.01) and degree of misreporting (r(s)=0.71, P=0.003, diet history; r(s)=0.63, P=0.01, food records). Variation in energy intake at dinner and over the whole day identified by the food records correlated positively with energy expenditure (r=0.58, P = 0.02) and misreporting on the diet history (r=0.62, P=0.01). Conclusions: Subjects who are highly active or who have variable dietary and exercise behaviour may be less accurate in reporting dietary intake. Our findings indicate that it may be necessary to screen for these characteristics in studies where accuracy of reporting at an individual level is critical. Sponsorship: The study was supported in part by Australian Research Council funds made available through the University of Wollongong.
Resumo:
Background Twin and family studies have shown that genetic effects explain a relatively high amount of the phenotypic variation in blood pressure. However, many studies have not been able to replicate findings of association between specific polymorphisms and diastolic and systolic blood pressure. Methods In a structural equation-modelling framework the authors investigated longitudinal changes in repeated measures of blood pressures in a sample of 298 like-sexed twin pairs from the population-based Swedish Twin Registry. Also examined was the association between blood pressure and polymorphisms in the angiotensin-I converting enzyme and the angiotensin 11 receptor type 1 with the 'Fulker' test Both linkage and association were tested simultaneously revealing whether the polymorphism is a Quantitative Trait Locus (QTL) or in linkage disequilibrium with the QTL. Results Genetic influences explained up to 46% of the phenotypic variance in diastolic and 63% of the phenotypic variance in systolic blood pressure. Genetic influences were stable over time and contributed up to 78% of the phenotypic correlation in both diastolic and systolic blood pressure. Non-shared environmental effects were characterised by time specific influences and little transmission from one time point to the next. There was no significant linkage and association between the polymorphisms and blood pressure. Conclusions There is a considerable genetic stability in both diastolic and systolic blood pressure for a 6-year period of time in adult life. Non-shared environmental influences have a small long-term effect Although associations with the polymorphisms could not be replicated, results should be interpreted with caution due to power considerations. (C) 2002 Lippincott Williams Wilkins.
Resumo:
Axe latitudinal gradients in regional diversity random or biased with respect to body size? Using data for the New World avifauna, I show that the slope of the increase in regional species richness from the Arctic to the equator is not independent of body size. The increase is steepest among small and medium-sized species, and shallowest among the largest species. This is reflected in latitudinal variation in the shape of frequency distributions of body sizes in regional subsets of the New World avifauna. Because species are added disproportionately in small and medium size classes towards low latitudes, distributions become less widely spread along the body size axis than expected from the number of species. These patterns suggest an interaction between the effects of latitude and body size on species richness, implying that mechanisms which vary with both latitude and body size may be important determinants of high tropical diversity in New World birds.
Resumo:
We show that by making conditional measurements on the Einstein-Podolsky-Rosen (EPR) squeezed vacuum [T. Opatrny, G. Kurizki, and D.-G. Welsch, Phys. Rev. A 61, 032302 (2000)], one can improve the efficacy of teleportation for both the position-difference, momentum-sum, and number-difference, phase-sum continuous variable teleportation protocols. We investigate the relative abilities of the standard and conditional EPR states, and show that by conditioning we can improve the fidelity of teleportation of coherent states from below to above the (F) over bar =2/3 boundary, thereby achieving unambiguously quantum teleportation.