162 resultados para Single-Trial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single cell genetic analysis is generally performed using PCR and FISH. Until recently, FISH has been the method of choice. FISH however is expensive, has significant misdiagnosis rates, can result in interpretation difficulties and is labour intensive making it unsuitable for high throughput processing. Recently fluorescent PCR reliability has increased to levels at or surpassing FISH whilst maintaining low cost. However, PCR accuracy has been a concern due to allelic dropout. Multiplex PCR can now increase accuracy by using multiple markers for each chromosome to firstly provide diagnosis if markers fail and,or secondly confirm diagnosis. We compare a variety of diagnostic methods and demonstrate for the first time a multiplex PCR system providing simultaneous diagnosis and confirmation of the major aneuploidy chromosomes (21, 18, 13) and sex as well as DNA fingerprint in single cells. We also discuss the implications of using PCR for aneuploidy screening in preimplantation genetic diagnosis. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To demonstrate that the combination of impression cytology and single cell DNA fingerprinting represents a powerful tool that is suitable for detecting transplanted cells after corneal limbal allografting. Methods, Fifty single cells were obtained by corneal impression cytology from 12 patients undergoing cataract surgery. Individual cells were isolated from samples by micromanipulation. Polymerase chain reaction and short tandem repeat profiling was used to obtain forensic standard DNA fingerprints from single cells. Blood samples taken at the time of impression cytology provided control fingerprints. Results, informative DNA fingerprints were obtained from all corneal samples and 66% (33 of 50 cells) of isolated single cells, Of all fingerprints obtained, most (91%, 30 of 33 fingerprints) corneal fingerprints matched corresponding blond sample fingerprints. At least one corneal fingerprint matched the corresponding blood sample fingerprint in 83% (10 of 12 patients) of the patients in the study, Conclusions. This extremely specific single cell DNA fingerprinting system permits accurate identification of individual corneal epithelial cells, allowing very reliable determination of their origin, which will enable host and donor cells to be distinguished from each other after keratolimbal allografting procedures. even if the host and donor are the same sex or siblings. These DNA fingerprinting methods allow assessment of quality and quantity of donor cell survival, as well as survival time. The extreme sensitivity and accuracy of the technique means that should contamination occur, it would be identified, thus ensuring meaningful results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the treatment of atherosclerotic disease, stenting in the presence of a glycoprotein (GP) IIb/IIIa antagonist is becoming an increasingly common procedure. The ‘Do Tirofiban and ReoPro Give Similar Efficacy Trial’ (TARGET) was designed to determine whether the cheaper tirofiban was as effective and safe as abciximab in the prevention of ischaemic events with stenting. Unexpectedly, abciximab was shown to be superior to tirofiban. Tirofiban is a selective GP IIb/IIIa antagonist whereas abciximab has additional anti-inflammatory actions, which may contribute to its superiority.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivated by recent experiments on electric transport through single molecules and quantum dots, we investigate a model for transport that allows for significant coupling between the electrons and a boson mode isolated on the molecule or dot. We focus our attention on the temperature-dependent properties of the transport. In the Holstein picture for polaronic transport in molecular crystals the temperature dependence of the conductivity exhibits a crossover from coherent (band) to incoherent (hopping) transport. Here, the temperature dependence of the differential conductance on resonance does not show such a crossover, but is mostly determined by the lifetime of the resonant level on the molecule or dot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image : To assess the potential for sucralfate administered rectally to reduce the risk of late rectal morbidity in patients undergoing nonconformal radiotherapy (RT) for carcinoma of the prostate and to study the variables potentially contributing to late rectal morbidity and particularly to explore the relationship between acute and late toxicity. Image : Eighty-six patients with localized prostate carcinoma were randomized in a double-blind, placebo-controlled study to a daily enema of 3 g of sucralfate in a 15-mL suspension or the same suspension without sucralfate. The enema began the first day of RT and was continued for 2 weeks after treatment completion. The primary end point of the study was acute Radiation Therapy Oncology Group (RTOG)/European Organization for Research and Treatment of Cancer (EORTC) toxicity; however, the patients were followed for an additional 5 years on a 6-month basis. The evaluation included late RTOG/EORTC toxicity and a patient self-assessment questionnaire. Image : With a median follow-up of 5 years, the Kaplan-Meier probability of late Grade 2 RTOG/EORTC toxicity was 12% (95% confidence interval [CI] 2–22%) for placebo and 5% (95% CI 0–12%) for sucralfate (p = 0.26). The probability of late rectal bleeding was 59% (95% CI 45–73%) for placebo and 54% (95% CI 40–68%) for sucralfate. No statistically significant difference was found between the treatment arms for the peak incidence of any of the other patient self-assessment variables. Cox proportional hazards modeling indicated acute RTOG/EORTC toxicity of Grade 2 or greater was associated with a hazard ratio of 2.74 (95% CI 1.31–5.73) for the development of late toxicity of Grade 1 or greater. Substituting the patient self-assessment variables for acute RTOG/EORTC toxicity revealed that rectal pain of a moderate or severe grade during RT was the best predictor of the subsequent development of late toxicity, with a hazard ratio of 3.44 (95% CI 1.68–7). Image : The results of this study do not support the use of sucralfate administered rectally as a method for reducing the late toxicity of nonconformal RT for prostate cancer. There appears to be an association between the development of acute and subsequent late toxicity, although the nature of this association remains to be determined

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: First, to assess the clinical effectiveness of hylan G-F 20 in an appropriate care treatment regimen (as defined by the American College of Rheumatology (ACR) 1995 guidelines) as measured by validated disease-specific outcomes and health-related quality of life endpoints for patients with osteoarthritis (OA) of the knee. Second, to utilize the measures of effectiveness and costs in an economic evaluation (see accompanying manuscript). Design: A total of 255 patients with OA of the knee were enrolled by rheumatologists or orthopedic surgeons into a prospective, randomized, open-label, 1-year, multi-centred trial, conducted in Canada. Patients were randomized to 'Appropriate care with hylan G-F 20' (AC+H) or 'Appropriate care without hylan G-F 20' (AC). Data were collected at clinic visits (baseline, 12 months) and by telephone (1, 2, 4, 6, 8, 10, and 12 months). Results: The AC+H group was superior to the AC group for all primary (% reduction in mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale: 38% vs 13%, P=0.0001) and secondary effectiveness outcome measures. These differences were all statistically significant and exceeded the 20% difference between groups seta priori by the investigators as the minimum clinically important difference. Health-related quality of life improvements in the AC+H group were statistically superior for the WOMAC pain, stiffness and physical function (all P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss techniques for producing, manipulating, and measuring qubits encoded optically as vacuum- and single-photon states. We show that a universal set of nondeterministic gates can be constructed using linear optics and photon counting. We investigate the efficacy of a test gate given realistic detector efficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined procedure for separating Lu, Hf, Sm, Nd, and rare earth elements (REEs) from a single sample digest is presented. The procedure consists of the following five steps: (1) sample dissolution via sodium peroxide sintering; (2) separation of the high field strength elements from the REEs and other matrix elements by a HF-free anion-exchange column procedure; (3) purification of Hf on a cation-exchange resin; (4) separation of REEs from other matrix elements by cation exchange; (5) Lu, Sm, and Nd separation from the other REEs by reversed-phase ion chromatography. Analytical reproducibilities of Sm-Nd and Lu-Hf isotope systematics are demonstrated for standard solutions and international rock reference materials. Results show overall good reproducibilities for Sm-Nd systematics independent of the rock type analyzed. For the Lu-Hf systematics, the reproducibility of the parent/daughter ratio is much better for JB-1 (basalt) than for two analyzed felsic crustal rocks (DR-N and an Archaean granitoid). It is demonstrated that this poorer reproducibility of the Lu/Hf ratio is truly caused by sample heterogeneity; thus, results are geologically reasonable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of permanently attaching piezoelectric transducers to structural surfaces has demonstrated great potential for quantitative non-destructive evaluation and smart materials design. For thin structural members such as composite laminated plates, it has been well recognized that guided Lamb wave techniques can provide a very sensitive and effective means for large area interrogation. However, since in these applications multiple wave modes are generally generated and the individual modes are usually dispersive, the received signals are very complex and difficult to interpret. An attractive way to deal with this problem has recently been introduced by applying piezoceramic transducer arrays or interdigital transducer (IDT) technologies. In this paper, the acoustic wave field in composite laminated plates excited by piezoceramic transducer arrays or IDT is investigated. Based on dynamic piezoelectricity theory, a discrete layer theory and a multiple integral transform method, an analytical-numerical approach is developed to evaluate the input impedance characteristics of the transducer and the surface velocity response of the plate. The method enables the quantitative evaluation of the influence of the electrical characteristics of the excitation circuit, the geometric and piezoelectric properties of the transducer array, and the mechanical and geometrical features of the laminate. Numerical results are presented to validate the developed method and show the ability of single wave mode selection and isolation. The results show that the interaction between individual elements of the piezoelectric array has a significant influence on the performance of the IDT, and these effects can not be neglected even in the case of low frequency excitation. It is also demonstrated that adding backing materials to the transducer elements can be used to improve the excitability of specific wave modes. (C) 2002 Elsevier Science Ltd. All rights reserved.