111 resultados para universal central extension
Resumo:
Black-striped wallabies (Macropus dorsalis) are uncommon to rare in most of their former range, yet in parts of central Queensland where they are still locally common they are regarded as a serious pasture pest. There is considerable pressure from cattle graziers to reduce their density because of the putative damage that they cause to cattle pasture. Here we examined the effects of this species and other herbivores on pasture by monitoring vegetation cover between 1993 and 1998 in exclosures in brigalow, and poplar box communities on three grazing properties in the Maranoa region. The exclosures selectively allowed access to either: all vertebrate grazers including cattle; rabbits, bettongs, and wallabies; rabbits and bettongs; no vertebrate grazers. The greatest effects on the structure and species composition of pasture were caused by cattle, but wallabies did consume commercially important quantities of grass at some times of the year. This conflicts with local opinion that sees wallabies as the major cause of pasture degradation. Herein lies the management problem that sees continued reduction in wallaby habitat, and fragmentation of the species.
Resumo:
The use of thermodilution and other methods of monitoring in dogs during surgery and critical care was evaluated. Six Greyhounds were anaesthetised and then instrumented by placing a thermodilution catheter into the pulmonary artery via the jugular vein. A catheter in the dorsal pedal artery also permitted direct measurement of arterial pressures. Core body temperature (degreesC) and central venous pressure (mmHg) were measured, while cardiac output (mL/min/kg) and mean arterial pressure (mmHg) were calculated. A mid-line surgical incision was performed and the physiological parameters were monitored for a total of two hours. All physiological parameters generally declined, although significant increases (P<0.05) were noted for cardiac output following surgical incision. Central venous pressure was maintained at approximately 0mmHg by controlling an infusion of sterile saline. Core body temperature decreased from 37.1+/-0.6degreesC (once instrumented) to 36.6+/-0.60degreesC (at the end of the study), despite warming using heating pads. Physiological parameters indicative of patient viability will generally decline during surgery without intervention. This study describes an approach that can be undertaken in veterinary hospitals to accurately monitor vital signs in surgical and critical care patients.
Resumo:
Actively warming patients during surgery is considered the best method of preventing inadvertent hypothermia due to multiple causes: anaesthetic depression of the hypothalamic thermoregulatory centre, cutaneous vasodilatation, reduction of heat production by skeletal muscles, cold intravenous fluid administration and heat loss from opened body cavities. To compare the effects of active peripheral skin warming and trunk warming on body temperature during surgery, 15 dogs undergoing ovariohysterectomy were studied using a prospective randomised trial design. Dogs were randomised into two groups: one group was warmed by compress leg pads (n=7) on limbs and the other group by a circulating warm water mattress (n=8), applied to the trunk. The rectal, oesophageal and room temperatures and relative humidity were measured. The results showed that the compress leg pads (active peripheral warming) were significantly (P
Resumo:
This study reports on a block clinical trial of two types of central venous catheters (CVCs): antiseptic-impregnated catheters (AIC) and non-impregnated catheters (non-AIC), on catheter tip colonization and bacteraemia. In total, 500 catheters were inserted in 390 patients over the 18 month study period, 260 (52.0%) AIC and 240 (48.0%) non-AIC. Of these, 460 (92.0%) tips (237 AIC and 223 non-AIC) were collected. While significantly fewer AIC, 14 (5.9%), than non-AIC, 30 (13.5%), catheters were colonized (P < 0.01), there was no difference in the rates of bacteraemias in the two groups (0.8% vs. 2.7%, respectively, P = 0.16). There were 6.87 (95% CI 3.38-14.26) and 16.92 (95% CI 10.61-27.12) colonized AIC and non-AIC catheters, respectively, per 1000 catheter days, a difference that was significant (P < 0.01). However, no difference emerged between bacteraemias in AIC and non-AIC catheters per 1000 catheter days measured at 0.98 (95% CI 0.24-5.54) and 3.38 (95% CI 1.29-9.34), respectively (P = 0.10). Of the 444 CVCs that were sited in the subclavian or jugular veins and had tips collected, significantly more catheters were colonized in the jugular group, 19 (20%), compared with the subclavian group, 24 (6.9%; P less than or equal to 0.01). Overall, the low rates of colonization and bacteraemia may be explained by the population studied, the policies used and the employment of a clinical nurse dedicated to CVC management. (C) 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.