102 resultados para discrete trial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crushing and grinding are the most energy intensive part of the mineral recovery process. A major part of rock size reduction occurs in tumbling mills. Empirical models for the power draw of tumbling mills do not consider the effect of lifters. Discrete element modelling was used to investigate the effect of lifter condition on the power draw of tumbling mill. Results obtained with PFC3D code show that lifter condition will have a significant influence on the power draw and on the mode of energy consumption in the mill. Relatively high lifters will consume less power than low lifters, under otherwise identical conditions. The fraction of the power that will be consumed as friction will increase as the height of the lifters decreases. This will result in less power being used for high intensity comminution caused by the impacts. The fraction of the power that will be used to overcome frictional resistance is determined by the material's coefficient of friction. Based on the modelled results, it appears that the effective coefficient of friction for in situ mill is close to 0.1. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The PFC3D (particle flow code) that models the movement and interaction of particles by the DEM techniques was employed to simulate the particle movement and to calculate the velocity and energy distribution of collision in two types of impact crusher: the Canica vertical shaft crusher and the BJD horizontal shaft swing hammer mill. The distribution of collision energies was then converted into a product size distribution for a particular ore type using JKMRC impact breakage test data. Experimental data of the Canica VSI crusher treating quarry and the BJD hammer mill treating coal were used to verify the DEM simulation results. Upon the DEM procedures being validated, a detailed simulation study was conducted to investigate the effects of the machine design and operational conditions on velocity and energy distributions of collision inside the milling chamber and on the particle breakage behaviour. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The power required to operate large mills is typically 5-10 MW. Hence, optimisation of power consumption will have a significant impact on overall economic performance and environmental impact. Power draw modelling results using the discrete element code PFC3D have been compared with results derived from the widely used empirical Model of Morrell. This is achieved by calculating the power draw for a range of operating conditions for constant mill size and fill factor using two modelling approaches. fThe discrete element modelling results show that, apart from density, selection of the appropriate material damping ratio is critical for the accuracy of modelling of the mill power draw. The relative insensitivity of the power draw to the material stiffness allows selection of moderate stiffness values, which result in acceptable computation time. The results obtained confirm that modelling of the power draw for a vertical slice of the mill, of thickness 20% of the mill length, is a reliable substitute for modelling the full mill. The power draw predictions from PFC3D show good agreement with those obtained using the empirical model. Due to its inherent flexibility, power draw modelling using PFC3D appears to be a viable and attractive alternative to empirical models where necessary code and computer power are available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim was to determine whether methadone maintenance treatment reduced heroin use, syringe sharing and HIV or hepatitis C incidence among prisoners. Methods: All eligible prisoners seeking drug treatment were randomised to methadone or a waitlist control group from 1997 to 1998 and followed up after 4 months. Heroin use was measured by hair analysis and self report; drugs used and injected and syringe sharing were measured by self report. Hepatitis C and HIV incidence was measured by serology. Results: Of 593 eligible prisoners, 382 (64%) were randomised to MMT (n = 191) or control (n = 191). 129 treated and 124 control subjects were followed up at 5 months. Heroin use was significantly lower among treated than control subjects at follow up. Treated subjects reported lower levels of drug injection and syringe sharing at follow up. There was no difference in HIV or hepatitis C incidence. Conclusions: Consideration should be given to the introduction of prison methadone programs particular where community based programs exist. (C) 2003 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the effects of aggressive lipid lowering on markers of ischemia, resistance vessel function, atherosclerotic burden, and Symptom status in patients with symptomatic coronary artery disease. METHODS: Sixty consecutive patients with coronary artery disease that was unsuitable for revascularization were assigned randomly to either usual therapy of lipids for patients with a low-density lipoprotein (LDL) cholesterol target level <116 mg/dL, or to a, more aggressive lipid-lowering strategy involving up to 80 mg/d of atorvastatin, with a target LDL cholesterol level <77 mg/dL. The extent and severity of inducible ischemia (by dobutamine echocardiography), vascular function.(brachial artery reactivity), atheroma burden (carotid intima-media thickness), and symptom status were evaluated blindly at baseline and after 12 weeks of treatment. RESULTS: After 12 weeks of treatment, patients in the aggressive therapy group had a significantly greater decrease in mean (+/- SD) LDL cholesterol level than those in the usual care group (29 +/- 38 mg/dL vs. 7 +/- 24 mg/dL, P = 0.03). Patients in the aggressive therapy group had a reduction in the number of ischemic wall segments (mean between-group difference of 1.3; 95% confidence interval: 0.1 to 2.0; P = 0.04), flow-mediated dilatation (mean between-group difference of 5.9%; 95% confidence interval: 2.5% to 9.4%; P = 0.001), and angina score after 12 weeks. There were no significant changes in atherosclerotic burden in either group. CONCLUSION: Patients with symptomatic coronary artery disease who are treated with aggressive lipid lowering have improvement of symptom status and ischemia that appears to reflect improved vascular function but not atheroma burden. Am J Med. 2003;114:445-453. (C) 2003 by Excerpta Medica Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Difference equations which may arise as discrete approximations to two-point boundary value problems for systems of second-order, ordinary differential equations are investigated and conditions are formulated under which solutions to the discrete problem are unique. Some existence, uniqueness implies existence, and convergence theorems for solutions to the discrete problem are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to examine the reproducibility of laboratory-based 40-km cycle time-trial performance on a stationary wind-trainer. Each week, for three consecutive weeks, and on different days, forty-three highly trained male cyclists ((x) over bar +/- SD; age = 25 +/- 6 y; mass = 75 +/- 7 kg; peak oxygen uptake [(V) over dot O-2 peak] = 64.8 +/- 5.2 ml x kg(-1) x min(-1)) performed: 1) a (V) over dot O-2 peak test, and 2) a 40-km time-trial on their own racing bicycle mounted to a stationary wind-trainer (Cateye - Cyclosimulator). Data from all tests were compared using a one-way analysis of variance. Performance on the second and third 40-km time-trials were highly related (r = 0.96; p < 0.001), not significantly different (57:21 +/- 2:57 vs. 57:12 +/- 3:14 min:s), and displayed a low coefficient of variation (CV) = 0.9 +/- 0.7%. Although the first 40-km time-trial (58:43 +/- 3:17min:s) was not significantly different from the second and third tests (p = 0.06), inclusion of the first test in the assessment of reliability increased within-subject CV to 3.0 +/- 2.9%. 40-km time-trial speed (km x h(-1)) was significantly (p < 0.001) related to peak power output (W; r = 0.75), (V) over dot O-2 peak (1 x min(-1); r = 0.53), and the second ventilatory turnpoint (1 x min(-1); r = 0.68) measured during the progressive exercise tests. These data demonstrate that the assessment of 40-km cycle time-trial performance in well-trained endurance cyclists on a stationary wind-trainer is reproducible, provided the athletes perform a familiarization trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on a block clinical trial of two types of central venous catheters (CVCs): antiseptic-impregnated catheters (AIC) and non-impregnated catheters (non-AIC), on catheter tip colonization and bacteraemia. In total, 500 catheters were inserted in 390 patients over the 18 month study period, 260 (52.0%) AIC and 240 (48.0%) non-AIC. Of these, 460 (92.0%) tips (237 AIC and 223 non-AIC) were collected. While significantly fewer AIC, 14 (5.9%), than non-AIC, 30 (13.5%), catheters were colonized (P < 0.01), there was no difference in the rates of bacteraemias in the two groups (0.8% vs. 2.7%, respectively, P = 0.16). There were 6.87 (95% CI 3.38-14.26) and 16.92 (95% CI 10.61-27.12) colonized AIC and non-AIC catheters, respectively, per 1000 catheter days, a difference that was significant (P < 0.01). However, no difference emerged between bacteraemias in AIC and non-AIC catheters per 1000 catheter days measured at 0.98 (95% CI 0.24-5.54) and 3.38 (95% CI 1.29-9.34), respectively (P = 0.10). Of the 444 CVCs that were sited in the subclavian or jugular veins and had tips collected, significantly more catheters were colonized in the jugular group, 19 (20%), compared with the subclavian group, 24 (6.9%; P less than or equal to 0.01). Overall, the low rates of colonization and bacteraemia may be explained by the population studied, the policies used and the employment of a clinical nurse dedicated to CVC management. (C) 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The outer-sphere redox behaviour of a series of [LnCoIII-NCFeII(CN)(5)](-) (L-n = n-membered pentadentate aza-macrocycle) complexes have been studied as a function of pH and oxidising agent. All the dinuclear complexes show a double protonation process at pH approximate to 2 that produces a shift in their UV/Vis spectra. Oxidation of the different non-protonated and diprotonated complexes has been carried out with peroxodisulfate, and of the non-protonated complexes also with trisoxalatocobaltate(III). The results are in agreement with predictions from the Marcus theory. The oxidation of [Fe(phen)(3)](3+) and [IrCl6](2-) is too fast to be measured, although for the latter the transient observation of the process has been achieved at pH = 0. The study of the kinetics of the outer-sphere redox process, with the S2O82- and [Co(ox)(3)](3-) oxidants, has been carried out as a function of pH, temperature, and pressure. As a whole, the values found for the activation volumes, entropies, and enthalpies are in the following margins, for the diprotonated and non-protonated dinuclear complexes, respectively: DeltaV(not equal) from 11 to 13 and 15 to 20 cm(3) mol(-1); DeltaS(not equal) from 110 to 30 and -60 to -90 J K-1 mol(-1); DeltaH(not equal) from 115 to 80 and 50 to 65 kJ.mol(-1). The thermal activation parameters are clearly dominated by the electrostriction occurring on outer-sphere precursor formation, while the trends found for the values of the volume of activation indicate an important degree of tuning due to the charge distribution during the electron transfer process. The special arrangement on the amine ligands in the isomer trans[(L14CoNCFeII)-N-III(CN)(5)](-) accounts for important differences in solvent-assisted hydrogen bonding occurring within the outer-sphere redox process, as has been established in redox reactions of similar compounds. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2003).