127 resultados para Neonatal hearing screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effect of high-pass filtering on TEOAE obtained from 2-month-old infants as a function of filter cut-off frequency, activity states and pass/fail status of infants. Two experiments were performed. In Experiment 1, 100 2-month-old infants (200 ears) in five activity states (asleep, awake but peaceful, sucking a pacifier, feeding, restless) were tested by use of TEOAE technology. Five different filter conditions were applied to the TEOAE responses post hoc. The filter conditions were set at 781 Hz (default setting), 1.0, 1.2, 1.4 and 1.6 kHz. Results from this experiment showed that TEOAE parameters, such as whole-wave reproducibility (WR) and signal-to-noise ratio (SNR) at 0.8 kHz and 1.6 kHz, changed as a function of the cut-off frequency. The findings suggest that the 1.6 kHz and 1.2 kHz filter conditions are optimal for WR and SNR pass/fail criteria, respectively. Although all infant recordings appeared to benefit from the filtering, infants in the noisy states seemed to benefit the most. In Experiment 2, the high-pass filtering technique was applied to 23 infants (35 ears) who apparently failed the TEOAE tests on initial screening but were subsequently awarded a pass status based on the results from a follow-up auditory brainstem response (ABR) assessment. The findings showed a significant decrease in noise contamination of the TEOAE with a corresponding significant increase in WR. With high-pass filtering at 1.6 kHz, 21/35 ears could be reclassified into the pass category.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Haemochromatosis associated with mutations in the HFE gene is the most common inherited disorder in Caucasian populations. Early diagnosis and treatment allows for normal life expectancy whereas there is considerable morbidity and early mortality in those patients diagnosed late or untreated. Unfortunately, the development of symptoms and signs in haemochromatosis is usually associated with significant iron overload. For this reason, many clinicians and geneticists have advocated population screening. The recent identification of the HFE gene and the availability of a simple DNA-based diagnostic test have led to international debate as to the most cost-effective means of population screening for HFE-associated haemochromatosis. The present paper summarizes the evidence in favour of population screening and analyses the relative advantages of genotypic (DNA test) versus phenotypic (transferrin saturation) testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the risk of conductive hearing loss in preterm infants with bronchopulmonary dysplasia (BPD) and preterm controls. Methodology: The study population consisted of 78 infants with BPD of 26-33 weeks gestation and 78 controls of similar gestational age matched for broad-based birthweight categories. An auditory brainstem response (ABR) audiology was performed shortly before hospital discharge. Visual reinforcement orientation audiometry (VROA) and impedance audiometry were performed at 8-12 months corrected for prematurity. Infants with persistent audiological abnormalities were referred for evaluation to paediatric ENT surgeons. Results: Infants with BPD had a significantly higher rate of ABR abnormalities (BPD: 22%, controls: 9%; P = 0.028). On VROA and impedance audiometry, the infants with BPD also had a higher rate of persistent abnormalities. Following ENT assessment, 22.1% of infants with BPD and 7.7% of controls had persistent conductive dysfunction requiring myringotomy and grommet tube insertion (P = 0.03). Most of these infants had normal ABR audiometry at hospital discharge. Conclusions: Preterm infants with BPD are at high risk of persistent conductive hearing loss late in the first year of life compared to controls. An ABR audiology conducted at the time of hospital discharge does not predict accurately later conductive hearing problems. Infants with BPD should have routine audiological evaluation toward the end of the first year of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of single Ca2+-activated K+ (BK) channels in neonatal rat intracardiac neurons were investigated using the patch-clamp recording technique. In symmetrical 140 mM K+, the single-channel slope conductance was linear in the voltage range -60/+60 mV. and was 207+/-19 pS. Na+ ions were not measurably permeant through the open channel. Channel activity increased with the cytoplasmic free Ca2+ concentration ([Ca2+],) with a Hill plot giving a half-saturating [Ca2+] (K-0.5) of 1.35 muM and slope of congruent to3. The BK channel was inhibited reversibly by external tetraethylammonium (TEA) ions, charybdotoxin, and quinine and was resistant to block by 4-aminopyridine and apamin. Ionomycin (1-10 muM) increased BK channel activity in the cell-attached recording configuration. The resting activity was consistent with a [Ca2+](i)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association of sustained cerebral edema with poor neurological outcome following hypoxia-ischaemia in the neonate suggests that measurement of cerebral edema may allow early prediction of outcome in these infants. Direct measurements of cerebral impedance have been widely used in animal studies to monitor cerebral edema, but such invasive measurements are not possible in the human neonate. This study investigated the ability of noninvasive cerebral impedance measurements to detect cerebral edema following hypoxia-ischaemia. One-day-old piglets were anaesthetized, intubated and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 4-6% O-2. Noninvasive cerebral bioimpedance was measured using gel electrodes attached to the scalp. Cerebral bioimpedance was also measured directly by insertion of two silver-silver chloride electrodes subdurally. Noninvasive and invasive measurements were made before, during and after hypoxia. Whole body impedance was measured to assess overall fluid movements. Intracranial pressure was measured continuously via a catheter inserted subdurally, as an index of cerebral edema. There was good agreement between noninvasive and invasive measurements of cerebral impedance although externally obtained responses were attenuated. Noninvasive measurements were also well correlated with intracranial pressure. Whole body impedance changes did not account for increases in noninvasively measured cerebral impedance. Results suggest that noninvasive cerebral impedance measurements do reflect intracranial events, and are able to detect cerebral edema following hypoxia-ischaemia in the neonate. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handedness, as a potentially influencing, nonpathologic factor, has not been investigated in relation to transient evoked otoacoustic emissions (TEOAEs). The present study aimed to examine the effects of handedness on the TEOAE spectrum in entry-level schoolchildren, with attention also to possible ear asymmetry. A total of 228 subjects (114 males, 114 females, mean age = 6.3 years) were tested using the ILO292 Otodynamics Analyzer (Quickscreen mode) in quiet rooms in 22 schools. For statistical analysis, subjects were matched for factors such as handedness, gender, age, and history of recent ear infection. The results from subjects with passing TEOAE, pure-tone screening, and tympanometry revealed no significant handedness effect overall, although a significant ear asymmetry effect on the measurement parameters of AB difference, noise level, response level, whole-wave reproducibility, band reproducibility, and signal-to-noise ratios was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100 000 compounds per second.