126 resultados para Jewel design
Resumo:
Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.
Resumo:
Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.
Resumo:
The complex design and development of a planar multilayer phased array antenna in microstrip technology can be simplified using two commercially available design tools 1) Ansoft Ensemble and 2) HP-EEsof Touchstone. In the approach presented here, Touchstone is used to design RF switches and phase shifters whose scattering parameters are incorporated in Ensemble simulations using its black box tool. Using this approach, Ensemble is able to fully analyze the performance of radiating and beamforming layers of a phased array prior to its manufacturing. This strategy is demonstrated in a design example of a 12-element linearly-polarized circular phased array operating at L band. A comparison between theoretical and experimental results of the array is demonstrated.
Resumo:
The design and development of two X-band amplifying reflectarrays is presented. The arrays use dual-polarized aperture coupled patch antennas with FET transistors and phasing circuits to amplify a microwave signal and to radiate it in a chosen direction. Two cases are considered, one when a reflectarray converts a spherical wave due to a feed horn into a plane wave radiated into a boresight direction, and two, when the reflectarray converts a spherical wave due to a dual-polarized four-element feed array into a co-focal spherical wave. This amplified signal is received in an orthogonal port of the feed array so that the entire structure acts as a spatial power combiner. The two amplifying arrays are tested in the near-field zone for phase distribution over their apertures to achieve the required beam formation. Alternatively, their radiation patterns or gains are investigated.
Resumo:
Design of liquid retaining structures involves many decisions to be made by the designer based on rules of thumb, heuristics, judgment, code of practice and previous experience. Various design parameters to be chosen include configuration, material, loading, etc. A novice engineer may face many difficulties in the design process. Recent developments in artificial intelligence and emerging field of knowledge-based system (KBS) have made widespread applications in different fields. However, no attempt has been made to apply this intelligent system to the design of liquid retaining structures. The objective of this study is, thus, to develop a KBS that has the ability to assist engineers in the preliminary design of liquid retaining structures. Moreover, it can provide expert advice to the user in selection of design criteria, design parameters and optimum configuration based on minimum cost. The development of a prototype KBS for the design of liquid retaining structures (LIQUID), using blackboard architecture with hybrid knowledge representation techniques including production rule system and object-oriented approach, is presented in this paper. An expert system shell, Visual Rule Studio, is employed to facilitate the development of this prototype system. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Cases of high-sided vehicles striking low bridges is a large problem in many countries, especially the UK. This paper describes an experiment to evaluate a new design of markings for low bridges. A full size bridge was constructed which was capable of having its overhead clearance adjusted. Subjects sat in a truck cab as. it drove towards the bridge and were asked to judge whether the vehicle could pass safely under the bridge. The main objective of the research, was to determine whether marking the bridge with a newly devised experimental marking would result in more cautious decisions from subjects regarding whether or not the experimental bridge structure could be passed under safely compared with the currently used UK bridge marking standard. The results show that the type of bridge marking influenced the level of caution associated with decisions regarding bridge navigation, with the new marking design producing the most cautious decisions for the two different bridge heights used, at all distances away from the bridge structure. Additionally, the distance before the bridge at which decisions were given had an effect on the level of caution associated with decisions regarding bridge navigation (the closer to the bridge, the more cautious the decisions became, irrespective of the marking design). The implications of these results for reducing the number of bridge strikes are discussed. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Cyclotides are a novel class of circular, disulfide-rich peptides (similar to 30 amino acids) that display a broad range of bioactivities and have exceptionally high stability. Their physical properties, which include resistance to thermal and enzymatic degradation, can be attributed to their unique cyclic backbone and knotted arrangement of disulfide bonds. The applicability of linear peptides as drugs is potentially limited by their susceptibility to proteolytic cleavage and poor bioavailability. Such limitations may be overcome by using the cyclotide framework as a scaffold onto which new activities may be engineered. The potential use of cyclotides for drug design is evaluated here, with reference to rapidly increasing knowledge of natural cyclotides and the emergence of new techniques in peptide engineering.
Resumo:
We investigate the design of free-space optical interconnects (FSOIs) based on arrays of vertical-cavity surface-emitting lasers (VCSELs), microlenses, and photodetectors. We explain the effect of the modal structure of a multimodeVCSEL beam on the performance of a FSOI with microchannel architecture. A Gaussian-beam diffraction model is used in combination with the experimentally obtained spectrally resolved VCSEL beam profiles to determine the optical channel crosstalk and the signal-to-noise ratio (SNR) in the system. The dependence of the SNR on the feature parameters of a FSOI is investigated. We found that the presence of higher-order modes reduces the SNR and the maximum feasible interconnect distance. We also found that the positioning of a VCSEL array relative to the transmitter microlens has a significant impact on the SNR and the maximum feasible interconnect distance. Our analysis shows that the departure from the traditional confocal system yields several advantages including the extended interconnect distance and/or improved SNR. The results show that FSOIs based on multimode VCSELs can be efficiently utilized in both chip-level and board-level interconnects. (C) 2002 Optical Society of America.
Resumo:
The emphasis of this work is on the optimal design of MRI magnets with both superconducting coils and ferromagnetic rings. The work is directed to the automated design of MRI magnet systems containing superconducting wire and both `cold' and `warm' iron. Details of the optimization procedure are given and the results show combined superconducting and iron material MRI magnets with excellent field characteristics. Strong, homogeneous central magnetic fields are produced with little stray or external field leakage. The field calculations are performed using a semi-analytical method for both current coil and iron material sources. Design examples for symmetric, open and asymmetric clinical MRI magnets containing both superconducting coils and ferromagnetic material are presented.
Resumo:
Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.