84 resultados para instruments de gouverne
Resumo:
Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.
Resumo:
Little is known about risk management in the public sector This study reports on a survey of senior officers in Australian Commonwealth companies and statutory authorities concerning their practice and attitudes towards the use of derivative instruments for risk management. Using a variety of tests, the most important issue identified by respondents concerning the use of derivatives is for budgeting purposes. Of note, respondents rank commonly cited reasons advanced in the private sector such as reduced bankruptcy costs and taxation, as being relatively unimportant, which is consistent with arguments advanced in the paper The results also indicate that there are significant differences in the level of importance in some issues regarding derivatives use across public sector organisations, particularly those differentiated by a documented risk management plan. The study also documents for the first time the extent of derivatives use in the Australian public sector.
Resumo:
Quantification of calcium in the cuticle of the fly larva Exeretonevra angustifrons was undertaken at the micron scale using wavelength dispersive X-ray microanalysis, analytical standards, and a full matrix correction. Calcium and phosphorus were found to be present in the exoskeleton in a ratio that indicates amorphous calcium phosphate. This was confirmed through electron diffraction of the calcium-containing tissue. Due to the pragmatic difficulties of measuring light elements, it is not uncommon in the field of entomology to neglect the use of matrix corrections when performing microanalysis of bulk insect specimens. To determine, firstly, whether such a strategy affects the outcome and secondly, which matrix correction is preferable, phi-rho (z) and ZAF matrix corrections were contrasted with each other and without matrix correction. The best estimate of the mineral phase was found to be given by using the phi-rho (z) correction. When no correction was made, the ratio of Ca to P fell outside the range for amorphous calcium phosphate, possibly leading to flawed interpretation of the mineral form when used on its own.
Resumo:
Background: There is ample evidence of important symptomatic efficacy of tumour necrosis factor alpha (TNFalpha) inhibition in ankylosing spondylitis (AS). Moreover, studies suggest that anti-TNF could be considered as the first disease controlling antirheumatic treatment (DC-ART) for AS. Objective: To determine precisely which patients with AS are most likely to benefit from anti-TNFalpha treatment because of the cost and possible long term side effects of such treatment. Methods: Assessment in Ankylosing Spondylitis (ASAS) members were asked to use a Delphi technique to name the characteristics of patients with AS for whom they would start DC-ART, in three different clinical presentations (isolated axial involvement, peripheral arthritis, enthesitis). Results: Among the 62 invited ASAS members, more than 50% actively participated in the four phases of definition according to the Delphi technique. For each of the three clinical presentations, a combination of five to six domains was proposed, with an evaluation instrument and a cut off point defining a minimum level of activity for each domain. Conclusion: This study provides a profile for a patient with AS for considering initiation of biological agents that reflects the opinion of the ASAS members, using a Delphi exercise. Further studies are required to assess their relevance and their consistency with clinical practice.
Resumo:
[1] In this paper a detailed design, development and performances of a 5 GHz microstrip Yagi antenna, which uses a two-dimensional (2-D) electromagnetic band gap (EBG) structure in the ground plane, are presented. The results indicate that the use of the EBG structure improves the radiation pattern of the antenna. The cross polarization is suppressed by properly choosing the period and dimensions of EBGs. Also, the broadside gain is improved in comparison with the analogous antenna without the EBGs.
Resumo:
A method is presented for calculating the currents and winding patterns required to design independent zonal and tesseral shim coils for magnetic resonance imaging. Both actively shielded and unshielded configurations are considered, and the region of interest can be located asymmetrically with respect to the coil's length. Streamline, target-field and Fourier-series methods are utilized. The desired target-field is specified at two cylindrical radii, on and inside a circular conducting cylinder of length 2L and radius a. The specification is over some asymmetric portion pL < z < qL of the coil's length (-1 < p < q < 1). Arbitrary functions are used in the outer sections, -L < z < pL and qL < z < L, to ensure continuity of the magnetic field across the entire length of the coil. The entire field is then periodically extended as a half-range cosine Fourier series about either end of the coil. The resultant Fourier coefficients are then substituted into the Fourier-series expressions for the internal and external magnetic fields, and current densities and stream functions on both the primary coil and shield. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis and shielding analysis on field calculations from a ZX shim coil indicate that example designs and theory are well matched.
Resumo:
In small, cylindrical gradient coils consisting of a single layer of wires, the limiting factor in achieving large magnetic field gradients is the rapid increase in coil resistance with efficiency. This behavior results from the decrease in the maximum usable wire diameter as the number of turns is increased. By adopting a multilayer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favorable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. By extending the theory used to design standard cylindrical gradient coils, mathematical expressions have been developed that allow the design of multilayer coils. These expressions have previously been applied to the design of a four-layer z-gradient coil. As a further development, the equations have now been modified to allow the design of multilayer transverse gradient coils. The variation in coil performance with the number of layers employed has been investigated for coils of a size suitable for use in NMR microscopy, and the effect of constructing the coil using wires or cuts in a continuous conducting surface has also been assessed. We find that at fixed resistance a small wire-wound two-layer coil offers an increase in efficiency of a factor of about 1.5 compared with a single-layer coil. In addition, a two-layer coil of 10-mm inner diameter has been designed and built. This coil had an efficiency of 0.41 Tm-1 A(-1), a resistance of 0.96 +/- 0.01 Omega, and an inductance of 22.3 +/- 0.2 muH. The coil produces a gradient that deviates from linearity by less than 5% over a central cylindrical region of interest of height and length 6.2 mm. (C) 2003 Wiley Periodicals, Inc.
Resumo:
Measurement of Health-Related Quality of Life (HRQoL) of the elderly requires instruments with demonstrated sensitivity, reliability, and validity, particularly with the increasing proportion of older people entering the health care system. This article reports the psychometric properties of the 12-item Assessment of Quality of Life (AQoL) instrument in chronically ill community-dwelling elderly people with an 18-month follow-up. Comparator instruments included the SF-36 and the OARS. Construct validity of the AQoL was strong when examined via factor analysis and convergent and divergent validity against other scales. Receiver Operator Characteristic (ROC) curve analyses and relative efficiency estimates indicated the AQoL is sensitive, responsive, and had the strongest predicative validity for nursing home entry. It was also sensitive to economic prediction over the follow-up. Given these robust psychometric properties and the brevity of the scale, AQoL appears to be a suitable instrument for epidemiologic studies where HRQoL and utility data are required from elderly populations. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
The equipment used to measure magnetic fields and, electric currents in residences is described. The instrumentation consisted of current transformers, magnetic field probes and locally designed and, built signal conditioning modules. The data acquisition system was capable of unattended recording for extended time periods. The complete system was calibrated to verify its response to known physical inputs. (C) 2003 ISA-The Instrumentation Automation Society.