82 resultados para Exposure intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the effects of two high-intensity, treadmill interval-training programs on 3000-m and 5000-m running performance. Maximal oxygen uptake ((V) over dot O-2max), the running speed associated with (V) over dot O-2max (nu (V) over dot O-2max), the time for which nu (V) over dot O-2max can be maintained (T-max), running economy (RE), ventilatory threshold (VT) and 3000-m and 5000-m running times were determined in 27 well-trained runners. Subjects were then randomly assigned to three groups; (1) 60% T-max (2) 70% T-max and (3) control. Subjects in the control group continued their normal training and subjects in the two T-max groups undertook a 4-week treadmill interval-training program with the intensity set at nu (V) over dot O-2max and the interval duration at the assigned T-max. These subjects completed two interval-training sessions per week (60% T-max = six intervals/session, 70% T-max group = five intervals/session). Subjects were re-tested on all parameters at the completion of the training program. There was a significant improvement between pre- and post-training values in 3000-m time trial (TT) performance in the 60% T-max group compared to the 70% T,,a, and control groups [mean (SE); 60% T-max = 17.6 (3.5) s, 70% T-max = 6.3 (4.2) s, control = 0.5 (7.7) s]. There was no significant effect of the training program on 5000-m TT performance [60% T-max = 25.8 (13.8) s, 70% T-max = 3.7 (11.6) s, control = 9.9 (13.1) s]. Although there were no significant improvements in (V) over dot O-2max, nu (V) over dot (2max) and RE between groups, changes in (V) over dot O-2max and RE were significantly correlated with the improvement in the 3000-m TT. Furthermore, VT and T-max were significantly higher in the 60% Tmax group post-compared to pre-training. In conclusion, 3000-m running performance can be significantly improved in a group of well-trained runners, using a 4-week treadmill interval training program at nu (V) over dot O-2max with interval durations of 60% T-max.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to 1) examine the relationship between laboratory-based measures and high-intensity ultraendurance (HIU) performance during an intermittent 24-h relay ultraendurance mountain bike race (similar to20 min cycling, similar to60min recovery), and 2) examine physiological and performance based changes throughout the HIU event. Prior to the HIU event, four highly-trained male cyclists (age = 24.0 +/- 2.1 yr; mass = 75.0 +/- 2.7 kg; (V)over dot O-2peak = 70 +/- 3 ml.kg(-1).min(-1)) performed 1) a progressive exercise test to determine peak Volume of oxygen uptake ((V)over dot O-2peak), peak power output (PPO), and ventilatory threshold (T-vent), 2) time-to-fatigue tests at 100% (TF100) and 150% of PPO (TF150), and 3) a laboratory simulated 40-km time trial (TT40). Blood lactate (Lac(-)), haematocrit and haemoglobin were measured at 6-h intervals throughout the HIU event, while heart rate (HR) was recorded continuously. Intermittent HIU performance, performance HR, recovery HR, and Lac declined (P < 0.05), while plasma volume expanded (P < 0.05) during the HIU event. TF100 was related to the decline in lap time (r = -0.96; P < 0.05), and a trend (P = 0.081) was found between TF150 and average intermittent HIU speed (r = 0.92). However, other measures (V)over dot O-2peak, PPO, T-vent, and TT40) were not related to HIU performance. Measures of high-intensity endurance performance (TF100, TF150) were better predictors of intermittent HIU performance than traditional laboratory-based measures of aerobic capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sun exposure in childhood is I of the risk factors for developing skin cancer, yet little is known about levels of exposure at this age. This is particularly important in countries with high levels of ultraviolet radiation. (UVR) such as Australia. Among 49 children 3 to 5 years of age attending child care centers, UVR exposure was studied under 4 conditions in a repeated measures design; sunny days, cloudy days, teacher's instruction to stay in the shade, and a health professionals instruction to apply sunscreen. Three different data collection methods were employed: (a) completion of questionnaire or diary by parents and researcher, (b) polysulphone dosimeter readings, and (c) observational audits (video recording). Results of this study indicated that more than half the children had been sunburnt (pink or red) and more than a third had experienced painful sunburn (sore or tender) in the last summer. Most wore short sleeve shirts, short skirts or shorts and cap, that do not provide optimal levels of skin protection. However, sunscreen was applied to all exposed parts before the children went out to the playground. Over the period of I hr (9-10 a.m.) the average amount of time children spent in full sun was 22 min. On sunny days there was more variation across children in the amount of sun exposure received. While the potential amount of UVR exposure for young children during the hour they were outside on a sunny day was 1.45 MED (Minimum Erythemal Dose), they received on average 0.35 MED, which is an insufficient amount to result in an erythemal response on fair skin even without the use of sunscreen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The purpose of this study was to examine the reliability of stage of change (SOC) measures for moderate-intensity and vigorous physical activity in two separate samples of young adults. Staging measures have focused on vigorous exercise, but current public health guidelines emphasize moderate-intensity activity. Method. For college students in the USA (n = 105) and in Australia (n = 123), SOC was assessed separately on two occasions for moderate-intensity activity and for vigorous activity. Test-retest repeatability was determined, using Cohen's kappa coefficient. Results. In both samples, the reliability scores for the moderate-intensity physical activity staging measure were lower than the scores for the vigorous exercise staging measure. Weighted kappa values for the moderate-intensity staging measure were in the fair to good range for both studies (0.50 and 0.45); for the vigorous staging measure kappa values were excellent and fair to good (0.76 and 0.72). Conclusions. There is a need to standardize and improve methods for staging moderate-intensity activity, given that such measures are used in public health interventions targeting HEPA (health-enhancing physical activity). (C) 2003 American Health Foundation and Elsevier Science (USA). All rights reserved.