67 resultados para underground buildings
Resumo:
Colorimetric analysis of roadway dust is currently a method for monitoring the incombustible content of mine roadways within Australian underground coal mines. To test the accuracy of this method, and to eliminate errors of judgement introduced by human operators in the analysis procedure, a number of samples were tested using scanning software to determine absolute greyscale values. High variability and unpredictability of results was noted during this testing, indicating that colorimetric testing is sensitive to parameters within the mine that are not currently reproduced in the preparation of reference samples. This was linked to the dependence of colour on particle surface area, and hence also to the size distribution of coal particles within the mine environment. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Two hazard risk assessment matrices for the ranking of occupational health risks are described. The qualitative matrix uses qualitative measures of probability and consequence to determine risk assessment codes for hazard-disease combinations. A walk-through survey of an underground metalliferous mine and concentrator is used to demonstrate how the qualitative matrix can be applied to determine priorities for the control of occupational health hazards. The semi-quantitative matrix uses attributable risk as a quantitative measure of probability and uses qualitative measures of consequence. A practical application of this matrix is the determination of occupational health priorities using existing epidemiological studies. Calculated attributable risks from epidemiological studies of hazard-disease combinations in mining and minerals processing are used as examples. These historic response data do not reflect the risks associated with current exposures. A method using current exposure data, known exposure-response relationships and the semi-quantitative matrix is proposed for more accurate and current risk rankings.
Resumo:
The Green-striped burrowing frog. Cyclorana alboguttata survives extended drought periods by burrowing underground and aestivating. These frogs remain immobile within cocoons of shed skin and Mucus during aestivation and emerge from their burrows upon heavy rains to feed and reproduce. Extended periods of immobilisation in mammals typically result in muscle atrophy and a decrease in muscle performance. We examined the effect of aestivation and hence prolonged immobilisation, on skeletal Muscle mass. in vitro muscle performance, and locomotor performance in C. alboguttata. Frogs were aestivated in soil for 3 months and were compared with control animals that remained active, were fed, and had a continual supply of water. Compared to the controls, the wet mass of the gastrocnemius. sartorius, gracilus major. semimembranosus. peroneus, extensor cruris, tibialis posticus and tibialis anticus longus of aestivators remained unchanged indicating no muscle atrophy. The in-vitro performance characteristics of the gastroenemius muscle were maintained and burst swimming speed Was Unaffected, requiring no recovery from the extended period of immobilisation associated with aestivation. This preservation of muscle size, contractile condition and locomotor performance through aestivation enables C. alboguttata to compress their life history into unpredictable windows of opportunity, whenever heavy rains occur.
Resumo:
Passive techniques as an alternative to artificial cooling can bring important energy, environmental, financial, operational and qualitative benefits. However, regions such as the wet tropics can reach high levels of thermal stress in which passive means alone are unable to provide appropriate thermal comfort standards for some parts of the year. Despite a great accumulation of empirical information on the passive performance of houses for either free-running or conditioned modes, very little work has been done on the thermal performance of buildings that can operate with a mixed-running strategy in warm-humid climates. Buildings with such design features are able to balance the needs for comfort, privacy, and energy efficiency during different periods of the year. As free-running and conditioned modes are believed by many to be 'opposite' approaches, and have been presented as separate strategies, this paper demonstrates that not all parameters are directly opposite and a possible dual-mode integrated operation can be used for warm-humid locations for maximum comfort and minimum energy requirements. For this purpose, simulation runs using ESP-R (University of Strathclyde, ESRU, UK) were based on the climate data of Darwin (Australia) and on the ventilation styles of the house: free running and conditioned. Design features applicable to both, i.e. for a dual mode operation could be identified and the differences between conditioned and free running were demonstrated and proved not to be totally conflicting and therefore suitable for a dual mode operation. Different daily usage profiles (five use patterns were defined), and zoning of sleeping and living areas are presented. The dual mode use patterns compared to the base case house, for all the user possibilities, had improved performances of 17-52%, when compared to the free-running mode and 66-98% when compared to the conditioned mode. Simulation runs using other warm-humid climates (Miami, USA; Sao Luis, Brazil; Kuala Lumpur, Malaysia) were also conducted and compared to the results found for Darwin. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
In the last 7 years, a method has been developed to analyse building energy performance using computer simulation, in Brazil. The method combines analysis of building design plans and documentation, walk-through visits, electric and thermal measurements and the use of an energy simulation tool (DOE-2.1E code), The method was used to model more than 15 office buildings (more than 200 000 m(2)), located between 12.5degrees and 27.5degrees South latitude. The paper describes the basic methodology, with data for one building and presents additional results for other six cases. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
This study details the novel application of predacious copepods, genus Mesocyclops, for control of Ochlerotatus tremulus (Theobald) group and Aedes aegypti (L.) mosquito larvae in subterranean habitats in north Queensland, Australia. During June 1997, 50 Mesocyclops sp. I were inoculated into one service manhole in South Townsville. Wet season rainfall and flooding in both 1998 and 2000 was responsible for the dispersal of copepods via the underground pipe system to 29 of 35 manholes over an area of 1.33 km(2). Significant reductions in Aedes and Ochlerotatus larvae ensued. In these habitats, Mesocyclops and Metacyclops were able to survive dry periods, when substrate moisture content ranged from 13.8 to 79.9%. At the semiarid inland towns of Hughenden and Richmond, cracking clay soil prevents drainage of water from shallow service pits where Oc. tremulus immatures numbered from 292-18,460 per pit. Introduction of Mesocyclops copepods into these sites during May 1999 resulted in 100% control of Oc. tremulus for 18 mo. One uninoculated pit subsequently became positive for Mesocyclops with resultant control of mosquito larvae.
Resumo:
This paper presents an analysis of personal respirable coal dust measurements recorded by the Joint Coal Board in the underground longwall mines of New South Wales from 1985 to 1999. A description of the longwall mining process is given. In the study, 11 829 measurements from 33 mines were analysed and the results given for each occupation, for seven occupational groups, for individual de-identified mines and for each year of study. The mean respirable coal dust concentration for all jobs was 1.51 mg/m(3) (SD 1.08 mg/m(3)). Only 6.9% of the measurements exceeded the Australian exposure standard of 3 mg/m(3). Published exposure-response relationships were used to predict the prevalence of progressive massive fibrosis and the mean loss of FEV1, after a working lifetime (40 years) of exposure to the mean observed concentration of 1.5 mg/m(3). Prevalences of 1.3 and 2.9% were predicted, based on data from the UK and the USA, respectively. The mean loss of FEV1 was estimated to be 73.7 ml.