73 resultados para ultrafast ultrasound
Resumo:
Color Doppler ultrasound is a new method for documenting fluid leakage in the setting of video-urodynamic testing. In order to compare color Doppler ultrasound with traditional fluoroscopic imaging we performed a prospective blinded comparative clinical study. Fifty-two consecutive patients undergoing urodynamic investigations for symptoms of incontinence or prolapse were examined using fluoroscopy and translabial color Doppler ultrasound to document stress leakage. The investigators were blinded to each other's results. Both tests were performed at maximum bladder capacity and with an indwelling 5 Fr microtransducer catheter, in both the supine and the erect positions. Equivalent results for both methods were obtained in 48 out of 52 patients (Cohen's kappa = 0.82). It was therefore concluded that translabial color Doppler ultrasound imaging can reliably demonstrate leakage through the female urethra on Valsalva maneuver or coughing.
Resumo:
Purpose: To assess the toxicity and the efficacy of preoperative radiotherapy with continuous infusion 5-fluorouracil (5-FU) for locally advanced adenocarcinoma of the rectum. Methods and Materials: Eligible patients had newly diagnosed localized adenocarcinoma of the rectum within 12 cm of the anal verge, Stage T3-4, and were suitable for curative resection. Eighty-two patients were treated with radiotherapy-50.4 Gy in 28 fractions in 5.6 weeks, given concurrently with continuous infusion 5-FU, using either 96-h/week infusion at 300 mg/m(2)/day or 7-days/week infusion at 225 mg/m(2)/day. Results: The median age was 59 years (range, 27-87), and 67% of patients were male. Pretreatment stages of the rectal cancer were T3, 89% and resectable T4, 11%, with endorectal ultrasound confirmation in 67% of patients. Grade 3 acute toxicity occurred in 5 of 82 patients (6%; 95% confidence interval [CI], 2-14%). Types of surgical resection were anterior resection, 61%; abdominoperineal resection, 35%; and other procedures, 4%. There was no operative mortality. Anastomotic leakage after low anterior resection occurred in 3 of 50 patients (6%; 95% CI, 1-17%). The pathologic complete response rate was 16% (95% CI, 9-26%). Pathologic Stages T2 or less occurred in 51%. Conclusion: Preoperative radiotherapy with continuous infusion 5-FU for locally advanced rectal cancer is a safe regimen, with a significant downstaging effect. It does not seem to lead to a significant increase in serious surgical complications. (C) 2001 Elsevier Science Inc.
Resumo:
The objective of this study is to compare the accuracy of sonographic estimation of fetal weight of macrosomic babies in diabetic vs non-diabetic pregnancies. Ali babies weighing 4000 g or more at birth, and who had ultrasound scans performed within one week of delivery were included in this retrospective study. Pregnancies with diabetes mellitus were compared to those without diabetes mellitus. The mean simple error (actual birthweight - estimated fetal weight); mean standardised absolute error (absolute value of simple error (g)/actual birthweight (kg)); and the percentage of estimated birthweight falling within 15% of the actual birthweight between the two groups were compared. There were 9516 deliveries during the study period. Of this total 1211 (12.7 %) babies weighed 4000 g or more. A total of 56 non-diabetic pregnancies and 19 diabetic pregnancies were compared. The average sonographic estimation of fetal weight in diabetic pregnancies was 8 % less than the actual birthweight, compared to 0.2 % in the non-diabetic group (p < 0.01). The estimated fetal weight was within 15% of the birthweight in 74 % of the diabetic pregnancies, compared to 93 % of the non-diabetic pregnancies (p < 0.05). In the diabetic group, 26.3 % of the birthweights were underestimated by more than 15 %, compared to 5.4 % in the non-diabetic group (p < 0.05). In conclusion, the prediction accuracy of fetal weight estimation using standard formulae in macrosomic fetuses is significantly worse in diabetic pregnancies compared to non-diabetic pregnancies. When sonographic fetal weight estimation is used to influence the mode of delivery for diabetic women, a more conservative cut-off needs to be considered.
The relation between the transversus abdominis muscles, sacroilac joint mechanics, and low back pain
Resumo:
Study Design. Two abdominal muscle patterns were tested in the same group of individuals, and their effects were compared in relation to sacroiliac joint laxity. One pattern was contraction of the transversus abdominis, Independently of the other abdominals; the other was a bracing action that used all the lateral abdominal muscles. Objectives. To demonstrate the biomechanical effect of the exercise for the transversus abdominis known to be effective in low back pain. Summary of Background Data. Drawing in the abdominal wall is a specific exercise for the transversus abdominis muscle (in cocontraction with the multifidus), which is used in the treatment of back pain. Clinical effectiveness has been demonstrated to be a reduction of 3-year recurrence from 75% to 35%. To the authors' best knowledge, there is not yet in vivo proof of the biomechanical effect of this specific exercise. This study of a biomechanical model on the mechanics of the sacroiliac joint, however, predicted a significant effect of transversus abdominis muscle force. Methods. Thirteen healthy individuals who could perform the test patterns were included. Sacroiliac joint laxity values were recorded with study participants in the prone position during the two abdominal muscle patterns. The values were recorded by means of Doppler Imaging of vibrations. Simultaneous electromyographic recordings and ultrasound imaging were used to verify the two muscle patterns. Results. The range of sacroiliac joint laxity values observed in this study was comparable with levels found in earlier studies of healthy individuals. These values decreased significantly in all individuals during both muscle patterns (P < 0.001). The independent transversus abdominis contraction decreased sacroiliac joint laxity (or rather increased sacroiliac joint stiffness) to a significantly greater degree than the general abdominal exercise pat-tern (P < 0.0260). Conclusions. Contraction of the transversus abdominis significantly decreases the laxity of the sacroiliac joint. This decrease in laxity is larger than that caused by a bracing action using all the lateral abdominal muscles. These findings are in line with the authors' biomechanical model predictions and support the use of independent transversus abdominis contractions for the treatment of low back pain.
Resumo:
The current approach to prostate cancer diagnosis has major limitations including the inability of prostate-specific antigen (PSA) assays to accurately differentiate between prostate cancer and benign prostate hyperplasia (BPH) and the imprecision of transrectal ultrasound (TRUS) biopsy sampling. We have employed cDNA microarray screening to compare gene expression patterns in BPH and tumour samples to identify expression markers that may be useful in discriminating between these conditions. Screening of 3 individual cDNA arrays identified 8 genes with expression 3-fold greater in 6 tumour tissues than in 1 nontumour sample and I BPH sample. Real-time PCR was used to confirm the overexpression of these 8 genes and 12 genes selected from the literature against a panel of 17 tumours and I 1 BPH samples. Two genes, delta-catenin (delta-catenin; CTNND2) and prostate-specific membrane antigen (PSMA; FOLH1), were significantly overexpressed in prostate cancer compared to BPH. Prostate epithelial cells stained positively for S-catenin and PSMA in our prostate cancer tissues, whereas the majority of our BPH tissues were negative for both markers. Thus we have identified delta-catenin (not previously associated with prostatic adenocarcinoma) and confirmed the potential of PSMA as potential candidates for the diagnosis and management of prostate cancer. (C) 2002 Wiley-Liss. Inc.
Resumo:
A jugular venotomy technique was developed to attempt extraction of Dirofilaria immitis in cats. Seven cats were first examined by cardiac ultrasound to establish the location of adult D. immitis that had been inserted by jugular venotomy. The efficiency of an extractor catheter in surgically removing filariae similarly inserted into 13 experimental cats was then assessed. A mean extraction success rate of 96% was achieved. This technique would seem to be worthy of clinical use provided the filariae are in the right atrial area.
Resumo:
Four emerging high-energy non-thermal technologies may replace or augment heating for producing sterile low-acid food products. High pressure, high-voltage pulsed electric field, high-energy ultrasound and high-intensity pulsed light are all capable of reducing bacterial spore counts under certain conditions. However, only non-continuous high pressure treatments, at temperatures higher than ambient, are currently capable of completely inactivating spores and producing sterile food products. The first three technologies also reduce the resistance of spores to inactivation by heat.
Resumo:
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.
Resumo:
A retrospective review of ultrasound guided breast excisional biopsies performed in a Surgical Unit of Princess Alexandra Hospital in 1998-99 was undertaken to assess the use of ultrasound specimen radiography. In this series a total of 55 localization biopsies were performed for impalpable lesions in 53 women. In 21 patients (38%), specimen ultrasound was used to confirm that the lesion in question had been excised, whereas for 34 lesions (62%), specimen X-ray was undertaken. In a total of six cases (10.9% overall) the radiographic abnormality was seen on ultrasound only. Real-time specimen sonography is a technique which is very appropriately utilized in conjunction with ultrasound guided excisions and can be easily performed either in the radiology department or the operative suite With minimal time delay. It could have particular application for lesions that are detected in younger women with dense breast parenchyma. The results of this review confirm specimen sonography to be a reliable technique. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Objectives. This study aimed to determine the incidence of abdominal aortic aneurysm (AAA) in a large group of siblings of Australian AAA patients to determine if screening in this group is justified. Methods. 1254 siblings of 400 index AAA patients were identified and offered aortic ultrasound screening. An age and sex matched control group was recruited from patients having abdominal CT scans for non-vascular indications. AAA was defined by an infrarenal aortic diameter of greater than or equal to3 cm or a ratio of the infrarenal to suprarenal aortic diameter of greater than or equal to2.0. A ratio of 1.0-1.5 was considered normal, and a ratio of >1.5 to
Resumo:
Background. Regional left ventricular (LV) dysfunction may occur in patients with coronary artery disease (CAD) in the absence of infarction, but the causes of this phenomenon are unclear. We sought to identify whether changes in regional LV function were related to stenosis severity, using sensitive new ultrasound markers of function. Methods: We studied 67 individuals with no history of infarction and with normal LV systolic function: 49 patients with CAD and 18 control subjects without CAD. All patients underwent color Doppler tissue imaging, integrated backscatter (IB), anatomic M-mode echocardiography, and strain rate imaging to detect changes in structure and function. Peak early and late diastolic myocardial velocity, cyclic variation of IB, wall thickness, and percent wall thickening were measured in each basal and mid segment. Strain rate and peak systolic strain were calculated in each wall. CAD was defined as greater than or equal to 50% diameter stenosis. Normokinetic segments (n = 354) subtended by CAD were divided according to stenosis severity into 3 groups: group 1 (subtended by 50%-69% stenosis); group 2 (subtended by 70%-98% stenosis); and group 3 (subtended by greater than or equal to99% stenosis). Each parameter in each group was compared with that in 216 segments from control subjects. Results: Segments subtended by significant CAD showed lower peak early and late diastolic myocardial velocity compared with control segments. Group 3 showed significantly lower myocardial velocities than group 2 for both peak early (4.8 +/- 1.8 vs 6.0 +/- 2.0 cm/s, P
Resumo:
Translabial ultrasound is increasingly being used for the assessment of women presenting with pelvic floor dysfunction and incontinence (1,2). However, there is little information on normal values for bladder neck descent, with the two available studies disagreeing widely (3,4). No data has so far been published on mobility of the central and posterior compartment which can now also be assessed by ultrasound (5). This study presents normal values for urethral, bladder, cervical and rectal mobility in a cohort of young, stress continent, nulliparous nonpregnant women. Methods 118 nonpregnant nulliparous Caucasian women between 18 and 23 years of age were recruited for an ongoing twin study of pelvic floor function. Translabial ultrasound assessment of pelvic organ mobility was undertaken supine and after bladder emptying (6,7). The best of at least three effective Valsalva manoeuvres was used for evaluation, with no attempts at standardization of Valsalva pressure. Parameters of anterior compartment mobility were obtained by the use of on-screen calipers; cervical and rectal descent were evaluated on printouts. All examinations were carried out under direct supervision of the first author or by personnel trained by him for at least 100 consecutive assessments. Results The median age of participants in this study was 20 (range 18- 23). Mean body mass index was 23 (range 16.9- 36.7). Of 118 women, 2 were completely unable to perform a Valsalva manoeuvre despite repeated efforts at teaching and were excluded from analysis, as were ten women who complained of urinary stress incontinence, leaving 106 datasets. Average measurements for the parameters ‘retrovesical angle at rest’ (RVA-R) and on Valsalva (RVA-S), urethral rotation, bladder neck mobility, cysto-cele descent, cervical descent and descent of the rectal ampulla are given in Table 1.