112 resultados para prodrug pharmacokinetics
Resumo:
A retrospective review was undertaken in 744 patients who were dose-individualized with gentamicin once daily to evaluate a change in gentamicin clearance as a potential predictor of nephrotoxicity. The definition of nephrotoxicity was chosen to be a change in creatinine clearance greater than 20%. Similarly, a change in gentamicin clearance of greater than 20% was also considered a possible index of nephrotoxicity. Four criteria were developed to assess the usefulness of gentamicin clearance as a predictor of nephrotoxicity. Following the application of the inclusion/exclusion criteria, 132 patients were available for the analysis. The sensitivity, specificity, positive predictive value, and negative predictive value were assessed for each of the criteria. Receiver operating characteristic (ROC) curves were produced to determine if an optimum value in the change of gentamicin clearance could be found to maximize sensitivity and specificity. The overall incidence of nephrotoxicity based on a decrease in creatinine clearance by 20% or more was 3.8%. Women were overrepresented in the nephrotoxic group [71.4% versus 40.1% (P = 0.0025)]. Patients with nephrotoxicity had statistically longer treatment periods, increased cumulative dose, and more dosing predictions (P < 0.05 in each case). The sensitivity of the criteria ranged from 43 to 46%, and specificity ranged from 93 to 99%. The positive and negative predictive values ranged from 63 to 94% and 86 to 89%, respectively. In those patients in whom nephrotoxicity was predicted from a change in gentamicin clearance, this change occurred on average 3 days before the change in creatinine clearance (P < 0.05). A change in gentamicin clearance to predict nephrotoxicity may be a useful addition to current monitoring methods, although it is not the complete answer.
Resumo:
Recently, methods for computing D-optimal designs for population pharmacokinetic studies have become available. However there are few publications that have prospectively evaluated the benefits of D-optimality in population or single-subject settings. This study compared a population optimal design with an empirical design for estimating the base pharmacokinetic model for enoxaparin in a stratified randomized setting. The population pharmacokinetic D-optimal design for enoxaparin was estimated using the PFIM function (MATLAB version 6.0.0.88). The optimal design was based on a one-compartment model with lognormal between subject variability and proportional residual variability and consisted of a single design with three sampling windows (0-30 min, 1.5-5 hr and 11 - 12 hr post-dose) for all patients. The empirical design consisted of three sample time windows per patient from a total of nine windows that collectively represented the entire dose interval. Each patient was assigned to have one blood sample taken from three different windows. Windows for blood sampling times were also provided for the optimal design. Ninety six patients were recruited into the study who were currently receiving enoxaparin therapy. Patients were randomly assigned to either the optimal or empirical sampling design, stratified for body mass index. The exact times of blood samples and doses were recorded. Analysis was undertaken using NONMEM (version 5). The empirical design supported a one compartment linear model with additive residual error, while the optimal design supported a two compartment linear model with additive residual error as did the model derived from the full data set. A posterior predictive check was performed where the models arising from the empirical and optimal designs were used to predict into the full data set. This revealed the optimal'' design derived model was superior to the empirical design model in terms of precision and was similar to the model developed from the full dataset. This study suggests optimal design techniques may be useful, even when the optimized design was based on a model that was misspecified in terms of the structural and statistical models and when the implementation of the optimal designed study deviated from the nominal design.
Resumo:
The study was a comparison of bioassay and HPLC analysis of artesunate (ARTS) and dihydroartemisinin (DHA) in plasma. ARTS and DHA in plasma samples from patients treated with ARTS were quantified by HPLC and expressed as DHA. DHA-equivalents in the same plasma samples were measured using a standardised parasite culture technique. DHA concentrations estimated by both methods were highly correlated (bioassay = 0.96 x HPLC + 11.0; r(2) = 0.92). At high concentrations ( > 12 000 nmol/l) bioassay sometimes overestimated DHA. Bioassay of active drug in plasma correlates well with specific chemical analysis by HPLC. ARTS and DHA appear to account for the total antimalarial activity in plasma after ARTS administration. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
We measured plasma tafenoquine concentrations in Thai soldiers given a monthly regimen of tafenoquine to determine whether these concentrations adequately suppressed malarial infections on the Thai- Cambodian border. After receiving a treatment course of artesunate and doxycycline, 104 male soldiers were administered a loading dose of tafenoquine ( 400 mg daily for 3 days), followed by tafenoquine monthly ( 400 mg every 4 weeks) for 5 months. Consecutive monthly mean ( +/- standard deviation) trough plasma tafenoquine concentrations were 223 +/- 41, 127 +/- 29, 157 +/- 51. 120 +/- 24, and 88 +/- ng/ mL. Only 1 soldier developed malaria during the study. At the time of malaria diagnosis, his plasma tafenoquine concentration was 40 ng/ mL, which was similar to 3- fold lower than the trough concentrations of the other soldiers. Although low tafenoquine concentrations appear to be uncommon, additional investigations are needed to determine the relationship between plasma tafenoquine concentrations and suppression of malaria.
Resumo:
Aims Alpha-lipoic acid (ALA) is a thiol compound with antioxidant properties used in the treatment of diabetic polyneuropathy. ALA may also improve arterial function, but there have been scant human trials examining this notion. This project aimed to investigate the effects of oral and intra-arterial ALA on changes in systemic and regional haemodynamics, respectively. Methods In study 1, 16 healthy older men aged 58 +/- 7 years (mean +/- SD) received 600 mg of ALA or placebo, on two occasions 1 week apart, in a randomized cross-over design. Repeated measures of peripheral and central haemodynamics were then obtained for 90 min. Central blood pressure and indices of arterial stiffness [augmentation index (AIx) and estimated aortic pulse wave velocity] were recorded non-invasively using pulse wave analysis. Blood samples obtained pre- and post-treatments were analysed for erythrocyte antioxidant enzyme activity, plasma nitrite and malondialdehyde. In study 2 the effects of incremental cumulative doses (0.5, 1.0, 1.5 and 2.0 mg ml(-1) min(-1)) of intra-arterial ALA on forearm blood flow (FBF) were assessed in eight healthy subjects (aged 31 +/- 5 years) by conventional venous occlusion plethysmography. Results There were no significant changes on any of the central or peripheral haemodynamic measures after either oral or direct arterial administration of ALA. Plasma ALA was detected after oral supplementation (95% confidence intervals 463, 761 ng ml(-1)), but did not alter cellular or plasma measures of oxidative stress. Conclusions Neither oral nor intra-arterial ALA had any effect on regional and systemic haemodynamics or measures of oxidative stress in healthy men.
Resumo:
The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.
Resumo:
The prevalence of obesity in the western world is dramatically rising, with many of these individuals requiring therapeutic intervention for a variety of disease states. Despite the growing prevalence of obesity there is a paucity of information describing how doses should be adjusted, or indeed whether they need to be adjusted, in the clinical setting. This review is aimed at identifying which descriptors of body size provide the most information about the relationship between dose and concentration in the obese. The size descriptors, weight, lean body weight, ideal body weight, body surface area, body mass index, fat-free mass, percent ideal body weight, adjusted body weight and predicted normal body weight were considered as potential size descriptors. We conducted an extensive review of the literature to identify studies that have assessed the quantitative relationship between the parameters clearance (CL) and volume of distribution (V) and these descriptors of body size. Surprisingly few studies have addressed the relationship between obesity and CL or V in a quantitative manner. Despite the lack of studies there were consistent findings: (i) most studies found total body weight to be the best descriptor of V. A further analysis of the studies that have addressed V found that total body weight or another descriptor that incorporated fat mass was the preferred descriptor for drugs that have high lipophilicity; (ii) in contrast, CL was best described by lean body mass and no apparent relationship between lipophilicity or clearance mechanism and preference for body size descriptor was found. In conclusion, no single descriptor described the influence of body size on both CL and V equally well. For drugs that are dosed chronically, and therefore CL is of primary concern, dosing for obese patients should not be based on their total weight. If a weight-based dose individualization is required then we would suggest that chronic drug dosing in the obese subject should be based on lean body weight, at least until a more robust size descriptor becomes available.
Resumo:
Objective: To develop a standard weight descriptor that can be used for estimation of patient size for obese patients. Patients and methods: Data were available from 3849 patients: 2839 from oncology patients (index data set) and 1010 from general medical patients (validation data set). The patients had a wide range of age (16-100 years), weight (25-165kg) and body mass index (BMI) [12-52 kg/m(2)] in both data sets. From the normal-weight patients in the oncology data set, an equation for male and female patients was developed to predict their normal weight as the sum of the lean body mass and normal fat body mass. The equations were evaluated by predicting the weight of patients in the general medical data set who had a normal BMI (30 kg/m(2)).
Resumo:
The current approach for therapeutic drug monitoring in renal transplant recipients receiving mycophenolate mofetil (MMF) is measurement of total mycophenolic acid (MPA) concentration. Because MPA is highly bound, during hypoalbuminemia the total concentration no longer reflects the free (pharmacologically active) concentration. The authors investigated what degree of hypoalbuminemia causes a significant change in protein binding and thus percentage free MPA. Forty-two renal transplant recipients were recruited for the study. Free and total concentrations of MPA (predose, and 1, 3, and 6 hours post-MMF dose samples) and plasma albumin concentrations were determined on day 5 posttransplantation. Six-hour area under the concentration-time curve (AUC(0-6)) values were calculated for free and total MPA, and percentage free MPA was determined for each patient. The authors found a significant relationship between low albumin concentrations and increased percentage free MPA (Spearman correlation = -0.54, P < 0.0001). Receiver operating characteristic (ROC) curve analysis was performed on the albumin versus percentage free MPA data. The cutoff value of albumin determined from the ROC analysis that differentiated normal from elevated percentage free MPA (defined as greater than or equal to3%) in this patient population was 31 g/L. At this cutoff value albumin was found to be a good predictor of altered free MPA percentage, with a sensitivity and specificity of 0.75 and 0.80, respectively, and an area under the ROC curve of 0.79. To rationalize MMF dosing regimens in hypoalbuminemic patients (plasma albumin less than or equal to 31 g/L), clinicians should consider monitoring the free MPA concentration.
Resumo:
Aims [1] To quantify the random and predictable components of variability for aminoglycoside clearance and volume of distribution [2] To investigate models for predicting aminoglycoside clearance in patients with low serum creatinine concentrations [3] To evaluate the predictive performance of initial dosing strategies for achieving an aminoglycoside target concentration. Methods Aminoglycoside demographic, dosing and concentration data were collected from 697 adult patients (>=20 years old) as part of standard clinical care using a target concentration intervention approach for dose individualization. It was assumed that aminoglycoside clearance had a renal and a nonrenal component, with the renal component being linearly related to predicted creatinine clearance. Results A two compartment pharmacokinetic model best described the aminoglycoside data. The addition of weight, age, sex and serum creatinine as covariates reduced the random component of between subject variability (BSVR) in clearance (CL) from 94% to 36% of population parameter variability (PPV). The final pharmacokinetic parameter estimates for the model with the best predictive performance were: CL, 4.7 l h(-1) 70 kg(-1); intercompartmental clearance (CLic), 1 l h(-1) 70 kg(-1); volume of central compartment (V-1), 19.5 l 70 kg(-1); volume of peripheral compartment (V-2) 11.2 l 70 kg(-1). Conclusions Using a fixed dose of aminoglycoside will achieve 35% of typical patients within 80-125% of a required dose. Covariate guided predictions increase this up to 61%. However, because we have shown that random within subject variability (WSVR) in clearance is less than safe and effective variability (SEV), target concentration intervention can potentially achieve safe and effective doses in 90% of patients.
Resumo:
The vast majority of biologically active compounds will never be considered as potential drugs due to inherently poor bioavailability. This review discusses the progress in the development of chemical systems to improve the metabolic stability, absorption and physicochemical properties of potential drugs. Delivery systems that involve the conjugation of lipid and/or sugar moieties are highlighted, as well as novel methods of conjugation of these groups to drugs. The use of sugar molecules to target drugs to particular organs or cells is also discussed, as is the use of lipids in the growing area of gene delivery. This is an update of a previous review [1].
Resumo:
We assessed monthly doses of tafenoquine for preventing Plasmodium vivax and multidrug-resistant P. falciparum malaria. In a randomized, double-blind, placebo-controlled study, 205 Thai soldiers received either a loading dose of tafenoquine 400 mg ( base) daily for 3 days, followed by single monthly 400-mg doses (n = 104), or placebo (n = 101), for up to 5 consecutive months. In volunteers completing follow-up (96 tafenoquine and 91 placebo recipients), there were 22 P. vivax, 8 P. falciparum, and 1 mixed infection. All infections except 1 P. vivax occurred in placebo recipients, giving tafenoquine a protective efficacy of 97% for all malaria (95% confidence interval [CI], 82%-99%), 96% for P. vivax malaria (95% CI, 76%-99%), and 100% for P. falciparum malaria ( 95% CI, 60%-100%). Monthly tafenoquine was safe, well tolerated, and highly effective in preventing P. vivax and multidrug-resistant P. falciparum malaria in Thai soldiers during 6 months of prophylaxis.
Resumo:
Objective-To investigate in vitro transdermal absorption of fentanyl from patches through skin samples obtained from various anatomic regions of dogs. Sample Population-Skin samples from 5 Greyhounds. Procedure-Skin samples from the dogs' thoracic, neck, and groin regions were collected postmortem and frozen. After samples were thawed, circular sections were cut and placed in Franz-type diffusion cells in a water bath (32degreesC). A commercial fentanyl patch, attached to an acetate strip with a circular hole, was applied to each skin sample. Cellulose strips were used as control membranes. Samples of receptor fluid in the diffusion cells were collected at intervals for 48 hours, and fentanyl concentrations were analyzed by use of high-performance liquid chromatography. Results-Mean +/- SD release rate of fentanyl from the patch, defined by its absorption rate through the non-rate-limiting cellulose membrane, was linear during the first 8 hours (2.01 +/- 0.05 pg/cm(2) of cellulose membrane/h) and then decreased. Fentanyl passed through skin from the groin region at a faster rate and with a significantly shorter lag time, compared with findings in neck or thoracic skin samples. Conclusions and Clinical Relevance-In vitro, fentanyl from a patch was absorbed more quickly and to a greater extent through skin collected from the groin region of dogs, compared with skin samples from the thoracic and neck regions. Placement of fentanyl patches in the groin region of dogs may decrease the lag time to achieve analgesia perioperatively; however, in vivo studies are necessary to confirm these findings.