74 resultados para competence test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coquillettidia linealis is a severe pest on some of the Moreton Bay islands in Queensland, Australia, but little is known of its breeding habitats and biology. Because of its high abundance and its association with Ross River (RR) and Barmah Forest (BF) viruses by field isolation, its vector competence was evaluated in the laboratory by feeding dilutions of both viruses in blood. For RR, Cq. linealis was of comparable efficiency to Ochlerotatus vigilax (Skuse), recognised as being a major vector. Results were as follows for Cq. linealis and Oc. vigilax , respectively: dose to infect 50%, 10(2.2) and

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two different doses of Ross River virus (1111) were fed to Ochlerotatus vigilax (Skuse), the primary coastal vector in Australia; and blood engorged females were held at different temperatures up to 35 d. After ingesting 10(4.3) CCID50/Mosquito, mosquitoes reared at 18 and 25degreesC (and held at the same temperature) had higher body remnant and head and salivary gland titers than those held at 32degreesC, although infection rates were comparable. At 18, 25, and 32degreesC, respectively, virus was first detected in the salivary glands on days 3, 2, and 3. Based on a previously demonstrated 98.7% concordance between salivary gland infection and transmission, the extrinsic incubation periods were estimated as 5, 4, and 3 d, respectively, for these three temperatures. When Oc. vigilax reared at 18, 25, or 32degreesC were fed a lower dosage of 10(3.3) CCID50 RR/mosquito, and assayed after 7 d extrinsic incubation at these (or combinations of these) temperatures, infection rates and titers were similar. However, by 14 d, infection rates and titers of those reared and held at 18 and 32degreesC were significantly higher and lower, respectively. However, this process was reversible when the moderate 25degreesC was involved, and intermediate infection rates and titers resulted. These data indicate that for the strains of RR and Oc. vigilax used, rearing temperature is unimportant to vector competence in the field, and that ambient temperature variations will modulate or enhance detectable infection rates only after 7 d: extrinsic incubation. Because of the short duration of extrinsic incubation, however, this will do little to influence RR epidemiology, because by this time some Oc. vigilax could be seeking their third blood meal, the latter two being infectious.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the motor and functional outcomes of 20 children with developmental coordination disorder (DCD) aged 4-8 years consecutively referred to a pediatric physiotherapy service. Children with a Movement ABC (M-ABC) score less than the 15th percentile, and with no concurrent medical, sensory, physical, intellectual or neurological impairments, were recruited. The Motor Assessment Outcomes Model (MAOM) [Coster and Haley, Infants and Young Children 4 (1992) 11] provided the theoretical base for measurement selection, and preliminary findings at the activities and participation levels of the model are reported in this article. Children with DCD performed at the lower end of the normal range on the Pea-body Developmental Motor Scales (fine motor total score) (M = 85.65, SD = 12.23). Performance on the Visual Motor Integration Test (VMI) standard scores was within the average range (M = 96.15, SD = 10.69). Videotaped observations of the children's writing and cutting indicated that 29% were left-handed and that a large proportion of all children (31%) utilized unusual pencil grasp patterns and immature prehension of scissors. Measurement at the participation level involved use of the Pictorial Scale of Perceived Competence and Social Acceptance (PCSA) and Pediatric Evaluation of Disability Inventory (PEDI). Overall, these young children rated themselves towards the more competent and accepted end of the PCSA over the dimensions of physical and cognitive competence and peer and maternal acceptance. The PEDI revealed generally average performance on social (M = 49.98, SD = 16.62) and mobility function (M = 54.71, SD = 3.99), however, self-care function was below the average range for age (M = 38.01, SD = 12.19). The utility of the MAOM as a framework for comprehensive measurement of functional and motor outcomes of DCD in young children is discussed. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australian Aedes aegypti (L.) mosquitoes colonized from the Torres Strait and three mainland localities (Charters Towers, Townsville, and Cairns) were fed on blood suspensions containing dengue virus type 2 (DEN-2) or dengue virus type 4 (DEN-4). Variation was found in oral susceptibility to DEN-2 (59-99% infection) and DEN-4 (28-79% infection) among Ae. aegypti assayed for virus at 8, 12, 16, or 20 d after ingestion of infected blood. Torres Strait Ae. aegypti were the most susceptible to DEN-2 and were significantly more efficient in transmission to capillary tube at 16 d (76% transmission) than mainland Ae. aegypti populations (20-28% transmission). Torres Strait Ae. aegypti were also the most susceptible to DEN-4, although transmission did not vary significantly from mainland populations at 16 d (12% compared with 0-4%) or 20 d (16% compared with 4-16%). Disseminated infection (i.e., leg infection) with either DEN-2 or DEN-4 was not an accurate predictor of transmission potential. This study demonstrates differences among Australian Ae. aegypti populations in vector competence for DEN-2 and DEN-4. Torres Strait Ae. aegypti were more frequently infected and able to transmit DEN-2 at higher rates than mainland populations. These data indicate that the Torres Strait region is potentially more receptive to dengue transmission than mainland localities, a finding discussed with respect to past outbreaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australian mosquitoes were evaluated for their ability to become infected with and transmit a Torres Strait strain of Japanese encephalitis virus. Mosquitoes, which were obtained from either laboratory colonies and collected using Centers for Disease Control and Prevention light traps baited with CO2 and octenol or reared from larvae, were infected by feeding on a blood/sucrose solution containing 10(4.5+/-0.1) porcine stable-equine kidney (PS-EK) tissue culture infectious dose(50)/ mosquito of the TS3306 virus strain. After 14 d, infection and transmission rates of 100% and 81%, respectively, were obtained for a southeast Queensland strain of Culex annulirostris Skuse, and 93% and 61%, respectively, for a far north Queensland strain. After 13 or more days, infection and transmission rates of > 90% and greater than or equal to 50%, respectively, were obtained for southeast Queensland strains of Culex sitiens Wiedemann and Culex quinquefasciatus Say, and a far north Queensland strain of Culex gelidus Theobald. Although infection rates were > 55%, only 17% of Ochlerotatus vigilax (Skuse) and no Cx. quinquefasciatus, collected from far north Queensland, transmitted virus. North Queensland strains of Aedes aegypti L., Ochlerotatus kochi (Donitz), and Verrallina funerea (Theobald) were relatively refractory to infection. Vertical transmission was not detected among 673 F, progeny of Oc. vigilax. Results of the current vector competence study, coupled with high field isolation rates, host feeding patterns and widespread distribution, confirm the status of Cx. annulirostris as the major vector of Japanese encephalitis virus in northern Australia. The relative roles of other species in potential Japanese encephalitis virus transmission cycles in northern Australia are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.