67 resultados para Spherical cavities


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The emphasis of this work is on the optimal design of MRI magnets with both superconducting coils and ferromagnetic rings. The work is directed to the automated design of MRI magnet systems containing superconducting wire and both `cold' and `warm' iron. Details of the optimization procedure are given and the results show combined superconducting and iron material MRI magnets with excellent field characteristics. Strong, homogeneous central magnetic fields are produced with little stray or external field leakage. The field calculations are performed using a semi-analytical method for both current coil and iron material sources. Design examples for symmetric, open and asymmetric clinical MRI magnets containing both superconducting coils and ferromagnetic material are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A model for binary mixture adsorption accounting for energetic heterogeneity and intermolecular interactions is proposed in this paper. The model is based on statistical thermodynamics, and it is able to describe molecular rearrangement of a mixture in a nonuniform adsorption field inside a cavity. The Helmholtz free energy obtained in the framework of this approach has upper and lower limits, which define a permissible range in which all possible solutions will be found. One limit corresponds to a completely chaotic distribution of molecules within a cavity, while the other corresponds to a maximum ordered molecular structure. Comparison of the nearly ideal O-2-N-2-zeolite NaX system at ambient temperature with the system Of O-2-N-2-zeolite CaX at 144 K has shown that a decrease of temperature leads to a molecular rearrangement in the cavity volume, which results from the difference in the fluid-solid interactions. The model is able to describe this behavior and therefore allows predicting mixture adsorption more accurately compared to those assuming energetic uniformity of the adsorption volume. Another feature of the model is its ability to correctly describe the negative deviations from Raoult's law exhibited by the O-2-N-2-CaX system at 144 K. Analysis of the highly nonideal CO2-C2H6-zeolite NaX system has shown that the spatial molecular rearrangement in separate cavities is induced by not only the ion-quadrupole interaction of the CO2 molecule but also the significant difference in molecular size and the difference between the intermolecular interactions of molecules of the same species and those of molecules of different species. This leads to the highly ordered structure of this system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actively warming patients during surgery is considered the best method of preventing inadvertent hypothermia due to multiple causes: anaesthetic depression of the hypothalamic thermoregulatory centre, cutaneous vasodilatation, reduction of heat production by skeletal muscles, cold intravenous fluid administration and heat loss from opened body cavities. To compare the effects of active peripheral skin warming and trunk warming on body temperature during surgery, 15 dogs undergoing ovariohysterectomy were studied using a prospective randomised trial design. Dogs were randomised into two groups: one group was warmed by compress leg pads (n=7) on limbs and the other group by a circulating warm water mattress (n=8), applied to the trunk. The rectal, oesophageal and room temperatures and relative humidity were measured. The results showed that the compress leg pads (active peripheral warming) were significantly (P

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is presented for calculating the currents and winding patterns required to design independent zonal and tesseral shim coils for magnetic resonance imaging. Both actively shielded and unshielded configurations are considered, and the region of interest can be located asymmetrically with respect to the coil's length. Streamline, target-field and Fourier-series methods are utilized. The desired target-field is specified at two cylindrical radii, on and inside a circular conducting cylinder of length 2L and radius a. The specification is over some asymmetric portion pL < z < qL of the coil's length (-1 < p < q < 1). Arbitrary functions are used in the outer sections, -L < z < pL and qL < z < L, to ensure continuity of the magnetic field across the entire length of the coil. The entire field is then periodically extended as a half-range cosine Fourier series about either end of the coil. The resultant Fourier coefficients are then substituted into the Fourier-series expressions for the internal and external magnetic fields, and current densities and stream functions on both the primary coil and shield. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis and shielding analysis on field calculations from a ZX shim coil indicate that example designs and theory are well matched.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several new lariat-crown ethers bearing either bridged bisdioxine or tetraoxaadamantane units as chiral substituents are prepared by reacting the corresponding amino-crown ether derivatives with the dimeric alpha-oxoketene, the latter obtained by flash vacuum pyrolysis of a furan-2,3-dione precursor. Complexation properties towards differently charged metal ions are investigated by H-1 NMR titration to obtain complexation constants (K-c-values for potassium/ sodium rhodanides: 480-1100 mol dm(-3)), as well as extraction experiments to explore the metal ion transportation abilities of the new lariat crown derivatives. In particular, a significantly increased ability to transport metal ions from water into chloroform was found with spherical tetraoxaadamantyl derivatives when compared with the free amino-benzocrown ethers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Low-temperature (15 K) single-crystal neutron-diffraction structures and Raman spectra of the salts (NX4)(2)[CU(OX2)(6)](SO4)(2), where X = H or D, are reported. This study is concerned with the origin of the structural phase change that is known to occur upon deuteration. Data for the deuterated salt were measured in the metastable state, achieved by application of 500 bar of hydrostatic pressure at similar to303 K followed by cooling to 281 K and the subsequent release of pressure. This allows for the direct comparison between the hydrogenous and deuterated salts, in the same modification, at ambient pressure and low temperature. The Raman spectra provide no intimation of any significant change in the intermolecular bonding. Furthermore, structural differences are few, the largest being for the long Cu-O bond, which is 2.2834(5) and 2.2802(4) Angstrom for the hydrogenous and the deuterated salts, respectively. Calorimetric data for the deuterated salt are also presented, providing an estimate of 0.17(2) kJ/mol for the enthalpy difference between the two structural forms at 295.8(5) K. The structural data suggest that substitution of hydrogen for deuterium gives rise to changes in the hydrogen-bonding interactions that result in a slightly reduced force field about the copper(II) center. The small structural differences suggest different relative stabilities for the hydrogenous and deuterated salts, which may be sufficient to stabilize the hydrogenous salt in the anomalous structural form.