71 resultados para Pulsed electric acoustic technique
Resumo:
Background: Presently the surgical approach to the adrenal gland is in a state of flux. While the traditional approach to the adrenal gland has been the open transabdominal technique, more recently laparoscopic approaches, particularly via the transabdominal route, have increasingly been utilized. However, laparoscopic intervention for the adrenal gland can be problematic in certain circumstances, particularly for large adrenal masses and in instances of adrenal malignancies. Methods: In this report we describe the use of hand-assisted laparoscopic adrenalectomy as an alternative minimal invasive surgical approach to the adrenal gland. Hand-assisted laparoscopic adrenalectomy using the HandPort system (Smith & Nephew, Sydney, Australia) was undertaken in three patients requiring adrenalectomy for mass lesions including one patient with Conn's syndrome. Results: In all three cases, surgery proceeded promptly and uneventfully. In the present paper, the details of the technique of hand-assisted adrenalectomy are described. This is the first report in the world literature of this new technique for the adrenal gland. Conclusions: Hand-assisted laparoscopic adrenalectomy is an easily performed technique, which can be completed within a short operative time span and which has the advantage of providing intraoperative tactile localization for the adrenal gland. It may be particularly applicable for large adrenal tumours, yet only involves the performance of a small abdominal incision. Postoperative recovery is comparable with that reported for the laparoscopic-only technique. Hand-assisted adrenalectomy is a new technique which has great potential and which warrants further evaluation.
Resumo:
Background and Objectives We have undertaken the first clinical trial involving the administration of alpha-GalactosylCeramine (alpha-GalCer)-pulsed dendritic cells (DCs) to human subjects, to determine safety, optimal dose, optimal administration route and immunological effects. Materials and Methods Subjects (n = 4) with metastatic malignancy received two infusions of alpha-GalCer-pulsed DCs intravenously, and two infusions intradermally. The percentages of Valpha24 Vbeta11 NKT cells in peripheral blood (PB) were determined by three-colour flow cytometry and the PB NKT cell numbers were calculated using the total number of PB lymphocytes/ml determined by automated full-blood counts. Results No serious treatment related adverse events were observed during the study period. Administration of alpha-GalCer-pulsed DCs in vivo can significantly (P < 0.03) increase PB Valpha24(+) Vbeta11(+) NKT cell numbers above pretreatment baseline levels after the transient fall in the NKT numbers within 48 h. Conclusions Administration of alpha-GalCer-pulsed DCs is well tolerated, modulates PB Valpha24(+) Vbeta11(+) NKT cells and may have a role in the therapy of malignancies sensitive to activities of Valpha24(+) Vbeta11(+) NKT cells, or for autoimmune diseases.
Resumo:
Background: The response of hepatocellular carcinoma (HCC) to therapy is often disappointing and new modalities of treatment are clearly needed. Active immunotherapy based on the injection of autologous dendritic cells (DC) co-cultured ex vivo with tumor antigens has been used in pilot studies in various malignancies such as melanoma and lymphoma with encouraging results. Methods: In the present paper, the preparation and exposure of patient DC to autologous HCC antigens and re-injection in an attempt to elicit antitumor immune responses are described. Results: Therapy was given to two patients, one with hepatitis C and one with hepatitis B, who had large, multiple HCC and for whom no other therapy was available. No significant side-effects were observed. The clinical course was unchanged in one patient, who died a few months later. The other patient, whose initial prognosis was considered poor, is still alive and well more than 3 years later with evidence of slowing of tumor growth based on organ imaging. Conclusions: It is concluded that HCC may be a malignancy worthy of DC trials and sufficient details in the present paper are given for the protocol to be copied or modified. (C) 2002 Blackwell Publishing Asia Pty Ltd.
Resumo:
Cervical auscultation presents as a noninvasive screening assessment of swallowing. Until now the focus of acoustic research in swallowing has been the characterization of swallowing sounds,. However, it may be that the technique is also suitable for the detection of respiratory sounds post swallow. A healthy relationship between swallowing and respiration is widely accepted as pivotal to safe swallowing. Previous investigators have shown that the expiratory phase of respiration commonly occurs prior to and after swallowing. That the larynx is valved shut during swallowing is also accepted. Previous research indicates that the larynx releases valved air immediately post swallow in healthy individuals. The current investigation sought to explore acoustic evidence of a release of subglottic air post swallow in nondysphagic individuals using a noninvasive medium. Fifty-nine healthy individuals spanning the ages of 18 to 60+ years swallowed 5 and 10 milliliters (ml) of thin and thick liquid boluses. Objective acoustic analysis was used to verify presence of the sound and to characterize its morphological features. The sound, dubbed the glottal release sound, was found to consistently occur in close proximity following the swallowing sound. The results indicated that the sound has distinct morphological features and that these change depending on the volume and viscosity of the bolus swallowed. Further research will be required to translate this information to a clinical tool.
Resumo:
Compression amplification significantly alters the acoustic speech signal in comparison to linear amplification. The central hypothesis of the present study was that the compression settings of a two-channel aid that best preserved the acoustic properties of speech compared to linear amplification would yield the best perceptual results, and that the compression settings that most altered the acoustic properties of speech compared to linear would yield significantly poorer speech perception. On the basis of initial acoustic analysis of the test stimuli recorded through a hearing aid, two different compression amplification settings were chosen for the perceptual study. Participants were 74 adults with mild to moderate sensorineural hearing impairment. Overall, the speech perception results supported the hypothesis. A further aim of the study was to determine if variation in participants' speech perception with compression amplification (compared to linear amplification) could be explained by the individual characteristics of age, degree of loss, dynamic range, temporal resolution, and frequency selectivity; however, no significant relationships were found.
Resumo:
In this paper we examine the effects of varying several experimental parameters in the Kane quantum computer architecture: A-gate voltage, the qubit depth below the silicon oxide barrier, and the back gate depth to explore how these variables affect the electron density of the donor electron. In particular, we calculate the resonance frequency of the donor nuclei as a function of these parameters. To do this we calculated the donor electron wave function variationally using an effective-mass Hamiltonian approach, using a basis of deformed hydrogenic orbitals. This approach was then extended to include the electric-field Hamiltonian and the silicon host geometry. We found that the phosphorous donor electron wave function was very sensitive to all the experimental variables studied in our work, and thus to optimize the operation of these devices it is necessary to control all parameters varied in this paper.
Resumo:
Prior theoretical studies indicate that the negative spatial derivative of the electric field induced by magnetic stimulation may he one of the main factors contributing to depolarization of the nerve fiber. This paper studies this parameter for peripheral nerve stimulation (PNS) induced by time.-varying gradient fields during MRI scans. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic human, full-body model. Whole-body cylindrical and planar gradient sets in MRI systems and various input signals have been explored. The spatial distributions of the induced electric field and their gradients are calculated and attempts are made to correlate these areas with reported experimental stimulation data. The induced electrical field pattern is similar for both the planar coils and cylindrical coils. This study provides some insight into the spatial characteristics of the induced field gradients for PNS in MRI, which may be used to further evaluate the sites where magnetic stimulation is likely to occur and to optimize gradient coil design.
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.
Influence of magnetically-induced E-fields on cardiac electric activity during MRI: A modeling study
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, time-varying gradient magnetic fields that may be able to induce electric fields (E-fields)/currents in tissues approaching the level of physiological significance. In this work we present theoretical investigations into induced E-fields in the thorax, and evaluate their potential influence on cardiac electric activity under the assumption that the sites of maximum E-field correspond to the myocardial stimulation threshold (an abnormal circumstance). Whole-body cylindrical and planar gradient coils were included in the model. The calculations of the induced fields are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, whole-body model. The potential for cardiac stimulation was evaluated using an electrical model of the heart. Twelve-lead electrocardiogram (ECG) signals were simulated and inspected for arrhythmias caused by the applied fields for both healthy and diseased hearts. The simulations show that the shape of the thorax and the conductive paths significantly influence induced E-fields. In healthy patients, these fields are not sufficient to elicit serious arrhythmias with the use of contemporary gradient sets. However, raising the strength and number of repeated switching episodes of gradients, as is certainly possible in local chest gradient sets, could expose patients to increased risk. For patients with cardiac disease, the risk factors are elevated. By the use of this model, the sensitivity of cardiac pathologies, such as abnormal conductive pathways, to the induced fields generated by an MRI sequence can be investigated. (C) 2003 Wiley-Liss, Inc.
Resumo:
A new method is presented which allows the separation of the soil aggregate exterior from the aggregate core. The method employs a combination of aggregate freezing with rapid separation of aggregate exteriors using ultrasonic energy. The factors influencing the thickness of the removed aggregate surface layer include water content of the aggregate prior to freezing, temperature difference between that of the frozen aggregate and that of the liquid it is submerged in during sonification, sonification time and energy, and the type of the immersion liquid. The success of the method and the thickness of the removed aggregate surface were examined using barium ( Ba2+) as a tracer. Barium ( as BaCl2) is rapidly absorbed by soil and is present at only very low levels in natural soils. Surface layers of 0.2 - 0.4 cm thickness were successfully removed from aggregates of 1 - 4 cm diameter. Two examples are given from soils in northern NSW to demonstrate the occurrence of small- scale heterogeneity in soil chemical properties. Compared with the surface fraction, a 4 - 7% higher calcium concentration was found in the core fraction of a clay loam soil ( Dermosol). Conversely, on a cracking clay soil ( Vertosol), atrazine concentration was around 15 times greater in the aggregate surface fractions compared with core fractions. Compared with the traditional estimation of soil chemical properties on homogenised bulk soil samples, it is suggested that separate analysis of aggregate surface and core fractions could provide useful additional information on the relationships between soil properties and environmental responses.