71 resultados para Parameters correlation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of number of samples and selection of data for analysis on the calculation of surface motor unit potential (SMUP) size in the statistical method of motor unit number estimates (MUNE) was determined in 10 normal subjects and 10 with amyotrophic lateral sclerosis (ALS). We recorded 500 sequential compound muscle action potentials (CMAPs) at three different stable stimulus intensities (10–50% of maximal CMAP). Estimated mean SMUP sizes were calculated using Poisson statistical assumptions from the variance of 500 sequential CMAP obtained at each stimulus intensity. The results with the 500 data points were compared with smaller subsets from the same data set. The results using a range of 50–80% of the 500 data points were compared with the full 500. The effect of restricting analysis to data between 5–20% of the CMAP and to standard deviation limits was also assessed. No differences in mean SMUP size were found with stimulus intensity or use of different ranges of data. Consistency was improved with a greater sample number. Data within 5% of CMAP size gave both increased consistency and reduced mean SMUP size in many subjects, but excluded valid responses present at that stimulus intensity. These changes were more prominent in ALS patients in whom the presence of isolated SMUP responses was a striking difference from normal subjects. Noise, spurious data, and large SMUP limited the Poisson assumptions. When these factors are considered, consistent statistical MUNE can be calculated from a continuous sequence of data points. A 2 to 2.5 SD or 10% window are reasonable methods of limiting data for analysis. Muscle Nerve 27: 320–331, 2003

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement while drilling (MWD) techniques can provide a useful tool to aid drill and blast engineers in open cut mining. By avoiding time consuming tasks such as scan-lines and rock sample collection for laboratory tests, MWD techniques can not only save time but also improve the reliability of the blast design by providing the drill and blast engineer with the information specially tailored for use. While most mines use a standard blast pattern and charge per blasthole, based on a single rock factor for the entire bench or blast region, information derived from the MWD parameters can improve the blast design by providing more accurate rock properties for each individual blasthole. From this, decisions can be made on the most appropriate type and amount of explosive charge to place in a per blasthole or to optimise the inter-hole timing detonation time of different decks and blastholes. Where real-time calculations are feasible, the system could extend the present blast design even be used to determine the placement of subsequent holes towards a more appropriate blasthole pattern design like asymmetrical blasting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adiabatic self-heating tests were carried out on five New Zealand coal samples ranging in rank from lignite to high-volatile bituminous. Kinetic parameters of oxidation were obtained front the self-heating curves assuming Arrhenius behaviour. The activation energy E (kJ mol(-1)) and the pre-exponential factor A (s(-1)) were determined in the temperature range of 70-140 degreesC. The activation energy exhibited a definite rank relationship with a minimum E of 55 kJ mol(-1) occurring at a Suggate rank of similar to6.2 corresponding to subbituminous C. Either side of this rank there was a noticeable increase in the activation energy indicating lower reactivity of the coal. A similar rank trend was also observed in the R-70 self-heating rate index values that were taken from the initial portion of the self-heating curve front 40 to 70 degreesC. From these results it is clear that the adiabatic method is capable of providing reliable kinetic parameters of coal oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the hypothesis that limited receptor solubility of lipophilic compounds may result in lower observed permeability parameters, the aim of this study was to determine the in vitro human epidermal permeability coefficients and membrane retention of a series of aliphatic alcohols (C1-C10, log p -0.72 to 4.06) using two different receptor solutions (water and 4% bovine serum albumin in phosphate-buffered saline). Aqueous solutions of radiolabeled alcohols were dosed into the stratum corneum side of membranes mounted in side-by-side glass diffusion cells. Appearance of alcohol in the receptor compartment filled with either of the two solutions was monitored over a 7 h period when both stratum corneum (assessed by tape stripping) and the remaining epidermis levels of radioactivity were determined. In a separate study the degree of binding of alcohols to 4% bovine serum albumin was determined. The data showed increased receptor phase solubility in the bovine serum albumin solution and higher permeability coefficients for the more lipophilic alcohols in the series. No changes were seen in the partitioning of the alcohols from the vehicle into either the stratum corneum or tape-stripped epidermis with the two receptor phases; however, a decrease in the amount of the more lipophilic alcohols partitioning into the water receptor phase from the tape-stripped epidermis was observed. We conclude that bovine serum albumin receptor phase allows better estimation of real permeability parameters for lipophilic compounds due to its increased solubility capacity and we question whether permeability parameters for lipophilic solutes from older data sets based on aqueous receptor phases are completely reliable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Male kids (110) from six goat genotypes, i.e. Boer x Angora (BA), Boer x Feral (1317), Boer x Saanen (BS), Feral x Feral (FF), Saanen x Angora (SA) and Saanen x Feral (SF) and two slaughter weight groups, i.e. Capretto and Chevon (liveweight at slaughter 14-22 and 30-35 kg, respectively) were compared for growth, carcass and meat quality characteristics. Due to their better growth rate, kids from BS and SF genotypes reached the required liveweight for slaughter earlier than kids from other Genotypes used in the study. Chevon kids had a significantly (P < 0.05) lower average daily gain (119 g per day) compared to Capretto kids (171 g per day). SA, SF and FF kids deposited more internal fat in comparison to kids from other genotypes. The dressing percentage of kids ranged from 51 to 54%, with significant differences between genotypes. BS and SF kids had longer carcasses. while BF kids had larger eye muscle area compared to other genotypes. Goat carcasses had a thin subcutaneous fat cover (1.6-2.2 mm). Genotype had a significant (P < 0.05) influence on cooking loss, pigment concentration and muscle colour parameters (CIE L*, a* and b* values). As denoted by the higher V and fibre optic probe values and lower subjective muscle score, the longissimus muscle colour was lighter for BS kids than other genotypes. Cooked meat from the BF kids had lower shear force values and better sensory scores compared to other genotypes. A significant (P < 0.05) decrease in muscle tenderness was observed from Capretto to Chevon carcasses, whereas cooked meat from these two slaughter weight groups was equally accepted (P > 0.05) by the panellists. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activated sludge floes are a flocculated mass of microorganisms, extracellular polymeric substances (EPS) and adsorbed organic and inorganic material. The structure of the floes is very heterogeneous and floes with very different properties and morphologies may occur, depending on the conditions in the activated sludge treatment plant and wastewater composition. Present thinking suggests that cations, such as calcium, create cationic bridges with EPS excreted by the bacteria and thereby hold the various floe constituents together. However, due to the complex and heterogeneous nature of activated sludge, the mechanisms have neither been thoroughly investigated nor successfully quantified. A better understanding and description of the biological flocculation process is necessary in order to establish more efficient operational strategies. The main aim of this study was to get a comprehensive and unique insight into the floe properties of activated sludge and to assess the relative impact of chemical and physical parameters. A variety of sludges from full scale treatment plants with different settling properties were characterised. The interrelationships between floe parameters such as composition of EPS, surface properties and floe structure, and their effect on the flocculation and separation properties were assessed. The results indicate that the EPS, both in terms of quantity and quality, are very important for the floe properties of the activated sludge. However, presence of filaments may alter the physical properties of the floes considerably. The EPS showed positive correlations to sludge volume index (SVI) if only sludges with low or moderate numbers of filaments were included. The surface properties were more affected by the composition of the EPS than by the number of filaments. The EPS showed positive correlation to negative surface charge and a negative correlation to relative hydrophobicity and flocculation ability. The negative correlation between flocculation ability and amount of EPS was surprising. The shear sensitivity, measured as degree of erosion of floes when subjected to shear, was more affected by floe size and number of filaments than amount of EPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As survival of patients with CF increases,glucose intolerance and cystic fibrosisrelated diabetes (CFRD),ar e increasingly recognised common complications. CFRD may be preceded by a pre-diabetic state. Using markers identified as being associated with CFRD may improve targeted screening. Aim: To identify features consistently predicting CFRD in paediatric patients. Patients diagnosed with CFRD between January 1997–January 2002 were compared with age and sex matched controls. Clinical,micr obiological, and hospitalisation data was collected at time of CFRD diagnosis,and at six monthly intervals for 3 yr prior to diagnosis. Eight patients with CFRD were identified,mean age 13.7 yr (S.D. 3.49) at time of diagnosis. Control patients underwent OGTT to ensure normal glucose tolerance. Patients with CFRD had a lower FEV1 up to 12 months prior to diagnosis however, this was only significant at diagnosis. There was no difference in weight and height z scores between the 2 groups; however,the decrease in weight and height z scores in the CFRD group over 3 yr prior to diagnosis was significant. Mean number of days in hospital and admissions per patient significantly increased in the CFRD group,6 months prior to diagnosis. No other significant differences were observed between the 2 groups. Conclusions: This study has shown a difference in lung function,gr owth parameters and frequency of hospital admissions between patients with CFRD and controls. These differences may be utilised as tools for targeted screening in the paediatricyadolescent population. Further larger scale studies are required to improve guidelines for targeted screening in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and aims: Hip fracture is a devastating event in terms of outcome in the elderly, and the best predictor of hip fracture risk is hip bone density, usually measured by dual X-ray absorptiometry (DXA). However, bone density can also be ascertained from computerized tomography (CT) scans, and mid-thigh scans are frequently employed to assess the muscle and fat composition of the lower limb. Therefore, we examined if it was possible to predict hip bone density using mid-femoral bone density. Methods: Subjects were 803 ambulatory white and black women and men, aged 70-79 years, participating in the Health, Aging and Body Composition (Health ABC) Study. Bone mineral content (BMC, g) and volumetric bone mineral density (vBMD, mg/cm(3)) of the mid-femur were obtained by CT, whereas BMC and areal bone mineral density (aBMD, g/cm(2)) of the hip (femoral neck and trochanter) were derived from DXA. Results: In regression analyses stratified by race and sex, the coefficient of determination was low with mid-femoral BMC, explaining 6-27% of the variance in hip BMC, with a standard error of estimate (SEE) ranging from 16 to 22% of the mean. For mid-femur vBMD, the variance explained in hip aBMD was 2-17% with a SEE ranging from 15 to 18%. Adjusting aBMD to approximate volumetric density did not improve the relationships. In addition, the utility of fracture prediction was examined. Forty-eight subjects had one or more fractures (various sites) during a mean follow-up of 4.07 years. In logistic regression analysis, there was no association between mid-femoral vBMD and fracture (all fractures), whereas a 1 SD increase in hip BMD was associated with reduced odds for fracture of similar to60%. Conclusions: These results do not support the use of CT-derived mid-femoral vBMD or BMC to predict DXA-measured hip bone mineral status, irrespective of race or sex in older adults. Further, in contrast to femoral neck and trochanter BMD, mid-femur vBMD was not able to predict fracture (all fractures). (C) 2003, Editrice Kurtis.