149 resultados para INTRINSIC VISCOSITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider one source of decoherence for a single trapped ion due to intensity and phase fluctuations in the exciting laser pulses. For simplicity we assume that the stochastic processes involved are white noise processes, which enables us to give a simple master equation description of this source of decoherence. This master equation is averaged over the noise, and is sufficient to describe the results of experiments that probe the oscillations in the electronic populations as energy is exchanged between the internal and electronic motion. Our results are in good qualitative agreement with recent experiments and predict that the decoherence rate will depend on vibrational quantum number in different ways depending on which vibrational excitation sideband is used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The role of beta(3)- and other putative atypical beta-adrenaceptors in human white adipocytes and right atrial appendage has been investigated using CGP 12177 and novel phenylethanolamine and aryloxypropanolamine beta(3)-adrenoceptor (beta(3)AR) agonists with varying intrinsic activities and selectivities for human cloned PAR subtypes. The ability to demonstrate beta(1/2)AR antagonist-insensitive (beta(3) or other atypical beta AR-mediated) responses to CGP 12177 was critically dependent on the albumin batch used to prepare and incubate the adipocytes. Four aryloxypropanolamine selective beta(3)AR agonists (SB-226552, SB-229432, SB-236923, SB-246982) consistently elicited beta(1/2)AR antagonist-insensitive lipolysis. However, a phenylethanolamine (SB-220646) that was a selective full beta(3)AR agonist elicited full lipolytic and inotropic responses that were sensitive to beta(1/2)AR antagonism, despite it having very low efficacies at cloned beta(1)- and beta(2)ARs. A component of the response to another phenylethanolamine selective beta(3)AR agonist (SB-215691) was insensitive to beta(1/2)AR antagonism in some experiments. Because novel aryloxypropanolamine had a beta(1/2)AR antagonist-insensitive inotropic effect, these results establish more firmly that beta(3)ARs mediate lipolysis in human white adipocytes, and suggest that putative 'beta(4)ARs' mediate inotropic responses to CGP 12177. The results also illustrate the difficulty of predicting from studies on cloned beta ARs which beta ARs will mediate responses to agonists in tissues that have a high number of beta(1)- and beta(2)ARs or a low number of beta(3)ARs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the adult male Sprague-Dawley rat, a species commonly used to study tolerance to the antinociceptive effects of morphine, approximate to 10% of the morphine dose is metabolized to normorphine-3-glucuronide (NM3G). In contrast, NM3G is a relatively minor metabolite of morphine in human urine reportedly accounting for approximate to 1% of the morphine dose. To date, the pharmacology of NM3G has been poorly characterized. Therefore, our studies were designed to determine whether the intrinsic pharmacology of NM3G is similar to that of morphine-3-glucuronide (M3G), the major metabolite of morphine, which has been shown to be a potent central nervous system (CNS) excitant and to attenuate the intrinsic antinociceptive effects of morphine in rats. The CNS excitatory potency of NM3G was found to be approximately half that of M3G, inducing convulsions in rats at intracerebroventricular (i.c.v.) doses of greater than or equal to 16.8 nmol. When administered before morphine (70 nmol i.c.v.), NM3G (8.9 nmol i.c.v.) attenuated antinociception for up to 2 hr, but when administered after morphine, no significant attenuation of morphine antinociception was observed. Thus, after i.c.v. administration, NM3G like M3G, is a potent CNS excitant and antianalgesic in the rat. NM3G may therefore play a role in the development of tolerance to the antinociceptive effects of morphine in the rat as has been proposed previously for M3G.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Six right-handed subjects performed rhythmic flexion and extension movements of the index finger in time with an auditory metronome. On each block of trials, the wrist of the response hand was placed in a extended, neutral or flexed position. In the flex-on-the-beat condition, subjects were instructed to coordinate maximum excursion in the direction of finger flexion with each beat of the metronome. In the extend-on-the-beat condition, subjects were instructed to coordinate maximum excursion in the direction of finger extension with each beat of the metronome. The frequency of the metronome was increased from 2.00 Hz to 3.75 Hz in 8 steps (8 s epochs) of 0.25 Hz. During trials prepared in the extend-on-the-beat pattern, all subjects exhibited transitions to either a flex-on-the-beat pattern or to phase wandering as the frequency of pacing was increased. The time at which these transitions occurred was reliably influenced by the position of the wrist. Four subjects exhibited qualitative departures from the flex-on-the-beat pattern at pacing frequencies that were greater than those at which the extend-on-the-beat pattern could be maintained. The lime at which these departures occurred was not influenced by the position of the wrist. These results are discussed with reference to the constraints imposed on the coordination dynamics by the intrinsic properties of the neuromuscular-skeletal system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydromorphone-3-glucuronide (H3G) was synthesized biochemically using rat liver microsomes, uridine-5'-diphosphoglucuronic acid (UDPGA) and the substrate, hydromorphone. Initially, the crude putative H3G product was purified by ethyl acetate precipitation and washing with acetonitrile, Final purification was achieved using semi-preparative high-performance-liquid-chromatography (HPLC) with ultraviolet (UV) detection. The purity of the final H3G product was shown by HPLC with electrochemical and ultraviolet detection to be > 99.9% and it was produced in a yield of approximate to 60% (on a molar basis). The chemical structure of the putative H3G was confirmed by enzymatic hydrolysis of the glucuronide moiety using P-glucuronidase, producing a hydrolysis product with the same HPLC retention time as the hydromorphone reference standard. Using HPLC with tandem mass spectrometry (HPLC-MS-MS) in the positive ionization mode, the molecular mass (M+1) was found to be 462 g/mol, in agreement with H3G's expected molecular weight of 461 g/mol. Importantly, proton-NMR indicated that the glucuronide moiety was attached at the 3-phenolic position of hydromorphone. A preliminary evaluation of H3G's intrinsic pharmacological effects revealed that following icy administration to adult male Sprague-Dawley rats in a dose of 5 mu g, H3G evoked a range of excitatory behavioural effects.including chewing, rearing, myoclonus, ataxia and tonic-clonic convulsions, in a manner similar to that reported previously for the glucuronide metabolites of morphine, morphine-3-glucuronide and normorphine-3-glucuronide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A theoretical analysis is carried out to investigate the pore-fluid pressure gradient and effective vertical-stress gradient distribution in fluid saturated porous rock masses in layered hydrodynamic systems. Three important concepts, namely the critical porosity of a porous medium, the intrinsic Fore-fluid pressure and the intrinsic effective vertical stress of the solid matrix, are presented and discussed. Using some basic scientific principles, we derive analytical solutions and explore the conditions under which either the intrinsic pore-fluid pressure gradient or the intrinsic effective vertical-stress gradient can be maintained at the value of the lithostatic pressure gradient. Even though the intrinsic pore-fluid pressure gradient can be maintained at the value of the lithostatic pressure gradient in a single layer, it is impossible to maintain it at this value in all layers in a layered hydrodynamic system, unless all layers have the same permeability and porosity simultaneously. However, the intrinsic effective vertical-stress gradient of the solid matrix can be maintained at a value close to the lithostatic pressure gradient in all layers in any layered hydrodynamic system within the scope of this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The degree and distribution of parasitisation in relation to densities of pink wax scale, Ceroplastes rubens Maskell, on umbrella trees, Schefflera actinophylla (Endl.), in south-eastern Queensland were investigated to determine whether scale outbreaks could be attributed, in part, to low levels of parasitisation. Rates of parasitisation were independent of or inversely dependent on host density, and highly variable, especially at low densities. The absence of density dependent parasitisation may occur as a result of: (i) non-aggregation by parasitoids; (ii) aggregation by parasitoids where parasitisation is limited by intrinsic or extrinsic factors; and/or (iii) high rates of hyperparasitisation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the X-ray properties of the Parkes sample of Bat-spectrum radio sources using data from the ROSAT All-Sky Survey and archival pointed PSPC observations. In total, 163 of the 323 sources are detected. For the remaining 160 sources, 2 sigma upper limits to the X-ray flux are derived. We present power-law photon indices in the 0.1-2.4 keV energy band for 115 sources, which were determined either with a hardness ratio technique or from direct fits to pointed PSPC data if a sufficient number of photons were available. The average photon index is <Gamma > = 1.95(-0.12)(+0.13) for flat-spectrum radio-loud quasars, <Gamma > = 1.70(-0.24)(+0.23) for galaxies, and <Gamma > = 2.40(-0.31)(+0.12) for BL Lac objects. The soft X-ray photon index is correlated with redshift and with radio spectral index in the sense that sources at high redshift and/or with flat (or inverted) radio spectra have flatter X-ray spectra on average. The results are in accord with orientation-dependent unification schemes for radio-loud active galactic nuclei. Webster et al. discovered many sources with unusually red optical continua among the quasars of this sample, and interpreted this result in terms of extinction by dust. Although the X-ray spectra in general do not show excess absorption, we find that low-redshift optically red quasars have significantly lower soft X-ray luminosities on average than objects with blue optical continua. The difference disappears for higher redshifts, as is expected for intrinsic absorption by cold gas associated with the dust. In addition, the scatter in log(f(x)/f(o)) is consistent with the observed optical extinction, contrary to previous claims based on optically or X-ray selected samples. Although alternative explanations for the red optical continua cannot be excluded with the present X-ray data, we note that the observed X-ray properties are consistent with the idea that dust plays an important role in some of the radio-loud quasars with red optical continua.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We derive analytical solutions for the three-dimensional time-dependent buckling of a non-Newtonian viscous plate in a less viscous medium. For the plate we assume a power-law rheology. The principal, axes of the stretching D-ij in the homogeneously deformed ground state are parallel and orthogonal to the bounding surfaces of the plate in the flat state. In the model formulation the action of the less viscous medium is replaced by equivalent reaction forces. The reaction forces are assumed to be parallel to the normal vector of the deformed plate surfaces. As a consequence, the buckling process is driven by the differences between the in-plane stresses and out of plane stress, and not by the in-plane stresses alone as assumed in previous models. The governing differential equation is essentially an orthotropic plate equation for rate dependent material, under biaxial pre-stress, supported by a viscous medium. The differential problem is solved by means of Fourier transformation and largest growth coefficients and corresponding wavenumbers are evaluated. We discuss in detail fold evolutions for isotropic in-plane stretching (D-11 = D-22), uniaxial plane straining (D-22 = 0) and in-plane flattening (D-11 = -2D(22)). Three-dimensional plots illustrate the stages of fold evolution for random initial perturbations or initial embryonic folds with axes non-parallel to the maximum compression axis. For all situations, one dominant set of folds develops normal to D-11, although the dominant wavelength differs from the Biot dominant wavelength except when the plate has a purely Newtonian viscosity. However, in the direction parallel to D-22, there exist infinitely many modes in the vicinity of the dominant wavelength which grow only marginally slower than the one corresponding to the dominant wavelength. This means that, except for very special initial conditions, the appearance of a three-dimensional fold will always be governed by at least two wavelengths. The wavelength in the direction parallel to D-11 is the dominant wavelength, and the wavelength(s) in the direction parallel to D-22 is determined essentially by the statistics of the initial state. A comparable sensitivity to the initial geometry does not exist in the classic two-dimensional folding models. In conformity with tradition we have applied Kirchhoff's hypothesis to constrain the cross-sectional rotations of the plate. We investigate the validity of this hypothesis within the framework of Reissner's plate theory. We also include a discussion of the effects of adding elasticity into the constitutive relations and show that there exist critical ratios of the relaxation times of the plate and the embedding medium for which two dominant wavelengths develop, one at ca. 2.5 of the classical Biot dominant wavelength and the other at ca. 0.45 of this wavelength. We propose that herein lies the origin of parasitic folds well known in natural examples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Strain-dependent hydraulic conductivities are uniquely defined by an environmental factor, representing applied normal and shear strains, combined with intrinsic material parameters representing mass and component deformation moduli, initial conductivities, and mass structure. The components representing mass moduli and structure are defined in terms of RQD (rock quality designation) and RMR (rock mass rating) to represent the response of a whole spectrum of rock masses, varying from highly fractured (crushed) rock to intact rock. These two empirical parameters determine the hydraulic response of a fractured medium to the induced-deformations The constitutive relations are verified against available published data and applied to study one-dimensional, strain-dependent fluid flow. Analytical results indicate that both normal and shear strains exert a significant influence on the processes of fluid flow and that the magnitude of this influence is regulated by the values of RQD and RMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The objectives of this study are, first, to replicate and extend an Australian approach to assessing mental health literacy by studying a sample of Singapore mental health professionals, and to focus on differences between judgements made by the psychiatrists in comparison with the other mental health professionals. Second, to compare the psychiatrists' judgements with those of Australian psychiatrists. Method: The Australian questionnaire, assessing responses in relation to vignettes of major depression and to schizophrenia was extended by adding a third vignette of mania, and by the addition of several region-specific response options. Nearly 500 questionnaires were distributed to representative staff (psychiatrists, nurses and allied health) of a large psychiatric institution in Singapore, with a response rate of 81%. Psychiatrists' judgements were compared with all other hospital staff, and with Australian psychiatrists' judgements. Results: The two principal contrast groups (Singapore psychiatrists and other Singapore mental health professionals) differed slightly in terms of diagnostic accuracy. The psychiatrists differed in favouring a more professionally focused model of intervention, while both professional groups viewed traditional healers and their practices as distinctly unhelpful. Direct comparison of psychiatrist ratings generated in Singapore and in Australia revealed quite similar response profiles. Conclusions: In addition to generating data of some intrinsic importance, comparison with Australian survey data allows the potential impact of regional and cultural differences, as well as of varying psychiatric practices, to be identified. Responses identified more similarities than differences in the judgements of the psychiatrists from the two countries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our previous studies indicate that oxycodone is a putative kappa-opioid agonist, whereas morphine is a well documented mu-opioid agonist. Because there is limited information regarding the development of tolerance to oxycodone, this study was designed to 1) document the development of tolerance to the antinociceptive effects of chronically infused i.v. oxycodone relative to that for i.v. morphine and 2) quantify the degree of antinociceptive cross-tolerance between morphine and oxycodone in adult male Dark Agouti (DA) rats. Antinociceptive testing was performed using the tail-flick latency test. Complete antinociceptive tolerance was achieved in 48 to 84 h after chronic infusion of equi-antinociceptive doses of i.v. oxycodone (2.5 mg/24 h and 5 mg/24 h) and i.v. morphine (10 mg/24 h and 20 mg/24 h, respectively). Dose-response curves for bolus doses of i.v. and i.c.v. morphine and oxycodone were produced in naive, morphine-tolerant, and oxycodone-tolerant rats. Consistent with our previous findings that oxycodone and morphine produce their intrinsic antinociceptive effects through distinctly different opioid receptor populations, there was no discernible cross-tolerance when i.c.v. oxycodone was given to morphine-tolerant rats. Similarly, only a low degree of cross-tolerance (approximate to 24%) was observed after i.v. oxycodone administration to morphine-tolerant rats. By contrast, both i.v. and i.c.v. morphine showed a high degree of cross-tolerance (approximate to 71% and approximate to 54%, respectively) in rats rendered tolerant to oxycodone. Taken together, these findings suggest that, after parenteral but not supraspinal administration, oxycodone is metabolized to a mu-opioid agonist metabolite, thereby explaining asymmetric and incomplete cross-tolerance between oxycodone and morphine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glutamate-mediated neurotransmission may be involved in the range of adaptive changes in brain which occur after ethanol administration in laboratory animals, and in chronic alcoholism in human cases. Excitatory amino acid transmission is modulated by a complex system of receptors and other effecters, the efficacy of which can be profoundly affected by altered gene or protein expression. Local variations in receptor composition may underlie intrinsic regional variations in susceptibility to pathological change. Equally, ethanol use and abuse may bring about alterations in receptor subunit expression as the essence of the adaptive response. Such considerations may underlie the regional localization characteristic of the pathogenesis of alcoholic brain damage, or they may form part of the homeostatic change that constitutes the neural substrate for alcohol dependence. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of initial perturbation geometry and material propel-ties on final fold geometry has been investigated using finite-difference (FLAC) and finite-element (MARC) numerical models. Previous studies using these two different codes reported very different folding behaviour although the material properties, boundary conditions and initial perturbation geometries were similar. The current results establish that the discrepancy was not due to the different computer codes but due to the different strain rates employed in the two previous studies (i.e. 10(-6) s(-1) in the FLAC models and 10(-14) s(-1) in the MARC models). As a result, different parts of the elasto-viscous rheological field were bring investigated. For the same material properties, strain rate and boundary conditions, the present results using the two different codes are consistent. A transition in Folding behaviour, from a situation where the geometry of initial perturbation determines final fold shape to a situation where material properties control the final geometry, is produced using both models. This transition takes place with increasing strain rate, decreasing elastic moduli or increasing viscosity (reflecting in each case the increasing influence of the elastic component in the Maxwell elastoviscous rheology). The transition described here is mechanically feasible but is associated with very high stresses in the competent layer (on the order of GPa), which is improbable under natural conditions. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective rheological assessment of fluids given to dysphagic patients at mealtime and during videofluoroscopy was carried out using a multicenter format. Thin, quarter-thick, half-thick and full-thick fluids were examined for the degree of correlation between mealtime fluids and their allegedly matched videofluoroscopy counterparts. The study was carried out to determine whether perceived subjective differences between mealtime fluids and videofluoroscopy fluids could be quantified using the rheological parameters of viscosity, density, and yield stress. The results showed poor correlation between mealtime fluids and videofluoroscopy fluids over all parameters. In general, the videofluoroscopy fluids were more viscous, more dense, and showed higher yield stress values than their mealtime counterparts. Given these results, it is reasonable to assume that the fluids used during videofluoroscopy do not provide an accurate indication of swallowing ability at mealtime. Therefore, it is suggested that clinicians use objective methods to theologically match videofluoroscopy fluids to mealtime fluids.