72 resultados para Hydrogen breath test
Resumo:
This paper tests the explanatory capacities of different versions of new institutionalism by examining the Australian case of a general transition in central banking practice and monetary politics: namely, the increased emphasis on low inflation and central bank independence. Standard versions of rational choice institutionalism largely dominate the literature on the politics of central banking, but this approach (here termed RC1) fails to account for Australian empirics. RC1 has a tendency to establish actor preferences exogenously to the analysis; actors' motives are also assumed a priori; actor's preferences are depicted in relatively static, ahistorical terms. And there is the tendency, even a methodological requirement, to assume relatively simple motives and preference sets among actors, in part because of the game theoretic nature of RC1 reasoning. It is possible to build a more accurate rational choice model by re-specifying and essentially updating the context, incentives and choice sets that have driven rational choice in this case. Enter RC2. However, this move subtly introduces methodological shifts and new theoretical challenges. By contrast, historical institutionalism uses an inductive methodology. Compared with deduction, it is arguably better able to deal with complexity and nuance. It also utilises a dynamic, historical approach, and specifies (dynamically) endogenous preference formation by interpretive actors. Historical institutionalism is also able to more easily incorporate a wider set of key explanatory variables and incorporate wider social aggregates. Hence, it is argued that historical institutionalism is the preferred explanatory theory and methodology in this case.
Resumo:
To determine which species and populations of Anopheles transmit malaria in any given situation, immunological assays for malaria sporozoite antigen can replace traditional microscopical examination of freshly dissected Anopheles. We developed a wicking assay for use with mosquitoes that identifies the presence or absence of specific peptide epitopes of circumsporozoite (CS) protein of Plasmodium falciparum and two strains of Plasmodium vivax (variants 210 and 247). The resulting assay (VecTest(TM) Malaria) is a rapid, one-step procedure using a 'dipstick' test strip capable of detecting and distinguishing between P. falciparum and P. vivax infections in mosquitoes. The objective of the present study was to test the efficacy, sensitivity, stability and field-user acceptability of this wicking dipstick assay. In collaboration with 16 test centres world-wide, we evaluated more than 40 000 units of this assay, comparing it to the standard CS ELISA. The 'VecTest(TM) Malaria' was found to show 92% sensitivity and 98.1% specificity, with 97.8% accuracy overall. In accelerated storage tests, the dipsticks remained stable for >15 weeks in dry conditions up to 45degreesC and in humid conditions up to 37degreesC. Evidently, this quick and easy dipstick test performs at an acceptable level of reliability and offers practical advantages for field workers needing to make rapid surveys of malaria vectors.
Resumo:
The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.
Resumo:
This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.
Resumo:
The radio frequency (RF) plasma-modified surfaces of kaolinite were investigated by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT) and deuteration techniques to determine the nature of RF plasma-induced surface functional groups, the altered sites in the lattice, and interaction mechanism between RF plasma and the surface of the kaolinite. It has been concluded that the RF plasma-induced infrared (IR) vibration absorption bands at 2805, 3010, and 3100 cm(-1) are attributable to the stretching vibration of hydrogen-bonded hydroxyl groups, and the band at 1407 cm(-1) is attributable to the bending vibration of (HO-)Al-O or (HO-)Si-O groupings with hydrogen-bonded hydroxyl groups. Structural alteration occurred on both the surface and subsurface region of the kaolinite during RF plasma treatment. Further structural alteration or adjustment was also observed on well-modified and well-deuterated kaolinite. There are two types of OD bands visible in the DRIFT spectra of this kaolinite, one type which decreased rapidly as a function of time in moist air, and the other which remained unchanged during the measurement. Furthermore, the appearance of broad IR bands at 3500-3100 cm(-1) as a result of deuteration is evidence of structural disturbance by RF plasma treatment lattice deuteration. An RF plasma-induced hydrogen bonding model on the surface of the kaolinite is proposed.
Resumo:
Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.