82 resultados para Frequency-Domain Analysis
Resumo:
The electromechanical transfer characteristics of adhesively bonded piezoelectric sensors are investigated. By the use of dynamic piezoelectricity theory, Mindlin plate theory for flexural wave propagation, and a multiple integral transform method, the frequency-response functions of piezoelectric sensors with and without backing materials are developed and the pressure-voltage transduction functions of the sensors calculated. The corresponding simulation results show that the sensitivity of the sensors is not only dependent on the sensors' inherent features, such as piezoelectric properties and geometry, but also on local characteristics of the tested structures and the admittance and impedance of the attached electrical circuit. It is also demonstrated that the simplified rigid mass sensor model can be used to analyze successfully the sensitivity of the sensor at low frequencies, but that the dynamic piezoelectric continuum model has to be used for higher frequencies, especially around the resonance frequency of the coupled sensor-structure vibration system.
Resumo:
Multiple frequency bioelectrical impedance analysis (MFBIA) has previously been shown to provide accurate relative measures of lymphedema in the upper limb of patients (1). This paper reports the results of a three year prospective study to evaluate the efficacy of MFBIA to predict the early onset of lymphedema in patients following treatment for breast cancer. Bioelectrical impedance measurements and circumferential measurements of each upper limb were recorded in healthy control subjects (n=60) to determine the normal range of the ratio (dominant/non-dominant) of extracellular and total limb volumes respectively. Patients undergoing surgery for the treatment of breast cancer were recruited as the study group; MFBIA and circumferential measurements were recorded pre-surgery, one month post-surgery and then at two month intervals for 24 months. One hundred and two patients were recruited into the study. Twenty patients developed lymphedema in the 24 months follow up period of this study. In each of these 20 cases MFBIA predicted the onset of the condition up to 10 months before the condition could be clinically diagnosed. Estimates of the sensitivity and specificity were both approximately 100%. At the time of detection by MFBIA, only one of the patients returned a positive test result from the total limb volumes determined from the circumferential measures. These results confirmed the suitability of the MFBIA technique as a reliable diagnostic procedure for the early detection of lymphedema.
Resumo:
Conventional whole-body single frequency bioelectrical impedance analysis (BIA) of body composition typically uses height as a surrogate measure of conductor length. A new method of BIA analysis for the prediction of body cell mass (BCM) and extracellular water (ECW, as % body weight) not using height has been introduced-the Soft Tissue Analyser (STA(TM), Akern Sri, Florence, Italy)-making it ideal for use in subjects where measurement of height is difficult or impossible. The performance of the new analytical method in predicting BCM and ECW in 139 normal control subjects was assessed by comparison with reference data obtained from a four-component (4-C) model of body composition and with predictions obtained from conventional BIA analysis. Both predicted BCM and ECW were strongly (r = 0.82, SEE = 6.3 kg and 0.89, SEE = 1.3 kg respectively) correlated with the corresponding 4-C model measurements although differing significantly from the lines of identity (P < 0.0001). Fat-free mass, calculated from STA estimates of BCM and ECW, was better predicted (r = 0.91, SEE = 5.6 kg). The significant differences in STA-group mean values for BCM and ECW and wide limits of agreement compared with the reference data indicate that the method cannot be used with confidence for prediction of these body compartments despite the obvious advantage of not requiring an accurate measurement of height. (C) 2001 Harcourt Publishers Ltd.
Resumo:
The acousto-ultrasonic (AU) input-output characteristics for contact-type transmitting and receiving transducers coupled to composite laminated plates are considered in this paper. Combining a multiple integral transform method, an ordinary discrete layer theory for the laminates and some simplifying assumptions for the electro-mechanical transduction behaviour of the transducers, an analytical solution is developed which can deal with all the wave processes involved in the AU measurement system, i.e, wave generation, wave propagation and wave reception. The spectral response of the normal contact pressure sensed by the receiving transducer due to an arbitrary input pulse excited by the transmitting transducer is obtained. To validate the new analytical-numerical spectral technique in the low-frequency regime, the results are compared with Mindlin plate theory solutions. Based on the analytical results, numerical calculations are carried out to investigate the influence of various external parameters such as frequency content of the input pulse, transmitter/receiver spacing and transducer aperture on the output of the measurement system. The results show that the presented analytical-numerical procedure is an effective tool for understanding the input-output characteristics of the AU technique for laminated plates. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Individuals with acute hepatitis B virus (HBV) infection characteristically mount a strong, multispecific cytotoxic T lymphocyte (CTL) response that is effective in eradicating virus. In contrast, this response in chronic carriers is usually weak or undetectable. Since it is generally acknowledged that HBV pathogenesis is immune-mediated, the occurrence of episodes of active liver disease in many carriers suggests that these individuals can mount active CTL responses to HBV. To see whether the detection of circulating CTLs is related to these flare episodes, we have determined the CTL precursor (CTLp) frequencies to HLA-A2-restricted viral peptides in seven patients over a 12-24-month period of their disease. Limiting dilution analyses (LDA) were performed longitudinally to five epitopes comprising the viral capsid (HBc), envelope (HBs) and polymerase (pol) proteins. Assays were performed against a mixture of peptides, or against each individual peptide, to measure overall CTL activity and the multispecificity of the responses, respectively. Since two of the patients were treated with recombinant human interleukin-12 (rHuIL-12) at the time, with one individual achieving complete disease remission a year later after being treated with interferon-alpha, we were also able to examine the effects of these cytokines on HBV cytotoxicity. Our results indicate that weak but detectable CTL responses do occur in chronic carriers which are generally associated with disease flares, although CTLps were also seen occasionally during minimal disease activity. The range of specificities varied between individuals and within each individual during the course of the disease. Finally, we also provide evidence that CTL reactivity is stimulated following treatment with certain cytokines, but is dependent on the time of administration.
Resumo:
Vesicular carriers for intracellular transport associate with unique sets of accessory molecules that dictate budding and docking on specific membrane domains. Although many of these accessory molecules are peripheral membrane proteins, in most cases the targeting sequences responsible for their membrane recruitment have yet to be identified. We have previously defined a novel Golgi targeting domain (GRIP) shared by a family of coiled-coil peripheral membrane Golgi proteins implicated in membrane trafficking. We show here that the docking site for the GRIP motif of p230 is a specific domain of Golgi. membranes. By immunoelectron microscopy of HeLa cells stably expressing a green fluorescent protein (GFP)-p230(GRIP) fusion protein, we show binding specifically to a subset of membranes of the trans-Golgi network (TGN). Real-time imaging of live HeLa cells revealed that the GFP-p230(GRIP) was associated with highly dynamic tubular extensions of the TGN, which have the appearance and behaviour of transport carriers. To further define the nature of the GRIP membrane binding site, in vitro budding assays were performed using purified rat liver Golgi membranes and cytosol from GFP-p230(GRIP) transfected cells. Analysis of Golgi-derived vesicles by sucrose gradient fractionation demonstrated that GFP-p230(GRIP) binds to a specific population of vesicles distinct from those labelled for beta -COP or gamma -adaptin. The GFP-p230(GRIP) fusion protein is recruited to the same vesicle population as full-length p230, demonstrating that the GRIP domain is solely proficient as a targeting signal for membrane binding of the native molecule. Therefore, p230 GRIP is a targeting signal for recruitment to a highly selective membrane attachment site on a specific population of trans-Golgi network tubulovesicular carriers.
Resumo:
This study investigated the residues responsible for the reduced picrotoxin sensitivity of the alpha beta heteromeric glycine receptor relative to the alpha homomeric receptor. By analogy with structurally related receptors, the beta subunit M2 domain residues P278 and F282 were considered the most likely candidates for mediating this effect. These residues align with G254 and T258 of the alpha subunit. The T258A, T258C and T258F mutations dramatically reduced the picrotoxin sensitivity of the alpha homomeric receptor. Furthermore, the converse F282T mutation in the beta subunit increased the picrotoxin sensitivity of the alpha beta heteromeric receptor. The P278G mutation in the beta subunit did not affect the picrotoxin sensitivity of the alpha beta heteromer. Thus, a ring of five threonines at the M2 domain depth corresponding to alpha subunit T258 is specifically required for picrotoxin sensitivity. Mutations to alpha subunit T258 also profoundly influenced the apparent glycine affinity. A substituted cysteine accessibility analysis revealed that the T258C sidechain increases its pore exposure in the channel open state. This provides further evidence for an allosteric mechanism of picrotoxin inhibition, but renders it unlikely that picrotoxin las an allosterically acting 'competitive' antagonist) binds to this residue.
Resumo:
The Sox gene family (Sry like HMG box gene) is characterised by a conserved DNA sequence encoding a domain of approximately 80 amino acids which is responsible for sequence specific DNA binding. We initially published the identification and partial cDNA sequence of murine Sox18, a new member of this gene family, isolated from a cardiac cDNA library. This sequence allowed us to classify Sox18 into the F sub-group of Sox proteins, along with Sox7 and Sox17. Recently, we demonstrated that mutations in the Sox18 activation domain underlie cardiovascular and hair follicle defects in the mouse mutation, ragged (Ra) (Pennisi et al., 2000. Mutations in Sox18 underlie cardiovascular and hair follicle defecs in ragged mice. Nat. Genet. 24, 434-437). Ra homozygotes lack vibrissae and coat hairs, have generalised oedema and an accumulation of chyle in the peritoneum. Here we have investigated the genomic sequences encoding Sox18. Screening of a mouse genomic phage library identified four overlapping clones, we sequenced a 3.25 kb XbaI fragment that defined the entire coding region and approximately 1.5 kb of 5' flanking sequences. This identified (i) an additional 91 amino acids upstream of the previously designated methionine start codon in the original cDNA, and (ii);ln intron encoded within the HMG box/DNA binding domain in exactly the same position as that found in the Sox5, -13 and -17 genes. The Sox18 gene encodes a protein of 468 aa. We present evidence that suggests HAF-2, the human HMG-box activating factor-2 protein, is the orthologue of murine Sox18. HAF-2 has been implicated in the regulation of the Human IgH enhancer in a B cell context. Random mutagenesis coupled with GAL4 hybrid analysis in the activation domain between amino acids 252 and 346, of Sox18, implicated the phosphorylation motif, SARS, and the region between amino acid residues 313 and 346 as critical components of Sox18 mediated transactivation. Finally, we examined the expression of Sox18 in multiple adult mouse tissues using RT-PCR. Low-moderate expression was observed in spleen, stomach, kidney, intestine, skeletal muscle and heart. Very abundant expression was detected in lung tissue. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A field matching method is described to analyze a recessed circular cavity radiating into a radial waveguide. Using the wall impedance approach, the analysis is divided into two separate problems of the cavity and its external environment. Based on this analysis, a computer algorithm is developed for determining wall admittances as seen at the edge of the patch in the cavity, the radial admittance matrix for the two-probe feed arrangement, and the input impedance as observed from the coaxial line feeding the cavity. This algorithm is tested against the general-purpose Hewlett-Packard finite-element High Frequency Structure Simulator as well as against measured results. Good agreement in all considered cases is noted.
Resumo:
The technique of permanently attaching interdigital transducers (IDT) to either flat or curved structural surfaces to excite single Lamb wave mode has demonstrated great potential for quantitative non-destructive evaluation and smart materials design, In this paper, the acoustic wave field in a composite laminated plate excited by an IDT is investigated. On the basis of discrete layer theory and a multiple integral transform method, an analytical-numerical approach is developed to evaluate the surface velocity response of the plate due to the IDTs excitation. In this approach, the frequency spectrum and wave number spectrum of the output of IDT are obtained directly. The corresponding time domain results are calculated by applying a standard inverse fast Fourier transformation technique. Numerical examples are presented to validate the developed method and show the ability of mode selection and isolation. A new effective way of transfer function estimation and interpretation is presented by considering the input wave number spectrum in addition to the commonly used input frequency spectrum. The new approach enables the simple physical evaluation of the influences of IDT geometrical features such as electrode finger widths and overall dimension and excitation signal properties on the input-output characteristics of IDT. Finally, considering the convenience of Mindlin plate wave theory in numerical computations as well as theoretical analysis, the validity is examined of using this approximate theory to design IDT for the excitation of the first and second anti-symmetric Lamb modes. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
The choice of genotyping families vs unrelated individuals is a critical factor in any large-scale linkage disequilibrium (LD) study. The use of unrelated individuals for such studies is promising, but in contrast to family designs, unrelated samples do not facilitate detection of genotyping errors, which have been shown to be of great importance for LD and linkage studies and may be even more important in genotyping collaborations across laboratories. Here we employ some of the most commonly-used analysis methods to examine the relative accuracy of haplotype estimation using families vs unrelateds in the presence of genotyping error. The results suggest that even slight amounts of genotyping error can significantly decrease haplotype frequency and reconstruction accuracy, that the ability to detect such errors in large families is essential when the number/complexity of haplotypes is high (low LD/common alleles). In contrast, in situations of low haplotype complexity (high LD and/or many rare alleles) unrelated individuals offer such a high degree of accuracy that there is little reason for less efficient family designs. Moreover, parent-child trios, which comprise the most popular family design and the most efficient in terms of the number of founder chromosomes per genotype but which contain little information for error detection, offer little or no gain over unrelated samples in nearly all cases, and thus do not seem a useful sampling compromise between unrelated individuals and large families. The implications of these results are discussed in the context of large-scale LD mapping projects such as the proposed genome-wide haplotype map.
Resumo:
Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model.
Resumo:
The tests that are currently available for the measurement of overexpression of the human epidermal growth factor-2 (HER2) in breast cancer have shown considerable problems in accuracy and interlaboratory reproducibility. Although these problems are partly alleviated by the use of validated, standardised 'kits', there may be considerable cost involved in their use. Prior to testing it may therefore be an advantage to be able to predict from basic pathology data whether a cancer is likely to overexpress HER2. In this study, we have correlated pathology features of cancers with the frequency of HER2 overexpression assessed by immunohistochemistry (IHC) using HercepTest (Dako). In addition, fluorescence in situ hybridisation (FISH) has been used to re-test the equivocal cancers and interobserver variation in assessing HER2 overexpression has been examined by a slide circulation scheme. Of the 1536 cancers, 1144 (74.5%) did not overexpress HER2. Unequivocal overexpression (3+ by IHC) was seen in 186 cancers (12%) and an equivocal result (2+ by IHC) was seen in 206 cancers (13%). Of the 156 IHC 3+ cancers for which complete data was available, 149 (95.5%) were ductal NST and 152 (97%) were histological grade 2 or 3. Only 1 of 124 infiltrating lobular carcinomas (0.8%) showed HER2 overexpression. None of the 49 'special types' of carcinoma showed HER2 overexpression. Re-testing by FISH of a proportion of the IHC 2+ cancers showed that only 25 (23%) of those assessable exhibited HER2 gene amplification, but 46 of the 47 IHC 3+ cancers (98%) were confirmed as showing gene amplification. Circulating slides for the assessment of HER2 score showed a moderate level of agreement between pathologists (kappa 0.4). As a result of this study we would advocate consideration of a triage approach to HER-2 testing. Infiltrating lobular and special types of carcinoma may not need to be routinely tested at presentation nor may grade 1 NST carcinomas in which only 1.4% have been shown to overexpress HER2. Testing of these carcinomas may be performed when HER2 status is required to assist in therapeutic or other clinical/prognostic decision-making. The highest yield of HER2 overexpressing carcinomas is seen in the grade 3 NST subgroup in which 24% are positive by IHC. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Compression amplification significantly alters the acoustic speech signal in comparison to linear amplification. The central hypothesis of the present study was that the compression settings of a two-channel aid that best preserved the acoustic properties of speech compared to linear amplification would yield the best perceptual results, and that the compression settings that most altered the acoustic properties of speech compared to linear would yield significantly poorer speech perception. On the basis of initial acoustic analysis of the test stimuli recorded through a hearing aid, two different compression amplification settings were chosen for the perceptual study. Participants were 74 adults with mild to moderate sensorineural hearing impairment. Overall, the speech perception results supported the hypothesis. A further aim of the study was to determine if variation in participants' speech perception with compression amplification (compared to linear amplification) could be explained by the individual characteristics of age, degree of loss, dynamic range, temporal resolution, and frequency selectivity; however, no significant relationships were found.
Resumo:
A high definition, finite difference time domain (HD-FDTD) method is presented in this paper. This new method allows the FDTD method to be efficiently applied over a very large frequency range including low frequencies, which are problematic for conventional FDTD methods. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and has been verified against analytical solutions within the frequency range 50 Hz-1 GHz. As an example of the lower frequency range, the method has been applied to the problem of induced eddy currents in the human body resulting from the pulsed magnetic field gradients of an MRI system. The new method only requires approximately 0.3% of the source period to obtain an accurate solution. (C) 2003 Elsevier Science Inc. All rights reserved.