73 resultados para Equality Screening
Resumo:
The purpose of this study was to compare transient evoked otoacoustic emission (TEOAE) screening outcomes (pass/fail) across the seasons (spring, autumn, and winter) between infants and schoolchildren. A total of 526 infants (275 boys, 251 girls) with a mean age of 2.0 months (SD = 0.38 months) and 975 schoolchildren (513 boys, 462 girls) with a mean age of 6.2 years (SD = 0.36 years) were screened using the ILO Otodynamics Quickscreen program. The same TEOAE pass/fail criterion was applied to the two groups. The results indicated a significant difference in pass rates between infants (91.2% of 1052 ears) and schoolchildren (86.0% of 1950 ears). A seasonal effect was found only for schoolchildren, with a significantly lower pass rate in winter than in spring or autumn. There was no difference in pass rates between spring and autumn. Implications for the seasonal effect on TEOAE screening outcomes for infants and schoolchildren are discussed.
Resumo:
High-throughput screening (HTS) using high-density microplates is the primary method for the discovery of novel lead candidate molecules. However, new strategies that eschew 2D microplate technology, including technologies that enable mass screening of targets against large combinatorial libraries, have the potential to greatly increase throughput and decrease unit cost. This review presents an overview of state-of-the-art microplate-based HTS technology and includes a discussion of emerging miniaturized systems for HTS. We focus on new methods of encoding combinatorial libraries that promise throughputs of as many as 100 000 compounds per second.
Resumo:
Objectives: To examine associations between nutrition screening checklists and the health of older women. Design: Cross-sectional postal survey including measures of health and health service utilisation, as well as the Australian Nutrition Screening Initiative (ANSI), adapted from the Nutrition Screening Initiative (NSI). Setting: Australia, 1996. Subjects: In total, 12 939 women aged 70-75 years randomly selected as part of the Australian Longitudinal Study on Women's Health. Results: Responses to individual items in the ANSI checklist, and ANSI and NSI scores, were associated with measures of health and health service utilisation. Women with high ANSI and NSI scores had poorer physical and mental health, higher health care utilisation and were less likely to be in the acceptable weight range. The performance of an unweighted score (TSI) was also examined and showed similar results. Whereas ANSI classified 30% of the women as 'high-risk', only 13% and 12% were classified as 'high-risk' by the NSI and TSI, respectively. However, for identifying women with body mass index outside the acceptable range, sensitivity, specificity and positive predictive values for all of these checklists were less than 60%. Conclusions: Higher scores on both the ANSI and NSI are associated with poorer health. The simpler unweighted method of scoring the ANSI (TSI) showed better discrimination for the identification of 'at risk' women than the weighted ANSI method. The predictive value of individual items and the checklist scores need to be examined longitudinally.
Resumo:
The validity of a brief self-report screening measure for elder abuse was examined on a nationally representative sample of more than 12,000 older women it? the baseline survey of the Australian Longitudinal Study on Women's Health. The screening instrument was a modification Of the Hwalek-Sengstock Elder Abuse Screening Test. Construct validity was examined using factor analysis and correlation with a wide range of sociodemographic, psychological. and health-related variables. Four factors, each of three items, were identified representing the following domains: Vulnerability, Dependence, Dejection, and Coercion. The Vulnerability and Coercion factors had the highest face validity for abuse and demonstrated moderate to good construct validity. The six items comprising these factors may provide a simple screening tool for elder abuse The identified correlates of abuse indicators have the potential to enhance policy development, screening, intervention, and carer support programs.
Resumo:
The flock-level sensitivity of pooled faecal culture and serological testing using AGID for the detection of ovine Johne's disease-infected flocks were estimated using non-gold-standard methods. The two tests were compared in an extensive field trial in 296 flocks in New South Wales during 1998. In each flock, a sample of sheep was selected and tested for ovine Johne's disease using both the AGID and pooled faecal culture. The flock-specificity of pooled faecal culture also was estimated from results of surveillance and market-assurance testing in New South Wales. The overall flock-sensitivity of pooled faecal culture was 92% (95% CI: 82.4 and 97.4%) compared to 61% (50.5 and 70.9%) for serology (assuming that both tests were 100% specific). In low-prevalence flocks (estimated prevalence
Resumo:
Objective: To assess the (i) benefits, (ii) harms and (iii) costs of continuing mammographic screening for women 70 years and over. Data sources and synthesis: (i) We conducted a MEDLINE search (1966 - July 2000) for decision-analytic models estimating life-expectancy gains from screening in older women. The five studies meeting the inclusion criteria were critically appraised using standard criteria. We estimated relative benefit from each model's estimate of effectiveness of screening in older women relative to that in women aged 50-69 years using the same model. (ii) With data from BreastScreen Queensland, we constructed balance sheets of the consequences of screening for women in 10-year age groups (40-49 to 80-89 years), and (iii) we used a validated model to estimate the marginal cost-effectiveness of extending screening to women 70 years and over. Results: For women aged 70-79 years, the relative benefit was estimated as 40%-72%, and 18%-62% with adjustment for the impact of screening on quality of life. For women over 80 years the relative benefit was about a third, and with quality-of-life adjustment only 14%, that in women aged 50-69 years. (ii) Of 10 000 Australian women participating in ongoing screening, about 400 are recalled for further testing, and, depending on age, about 70-112 undergo biopsy and about 19-80 cancers are detected. (iii) Cost-effectiveness estimates for extending the upper age limit for mammographic screening from 69 to 79 years range from $8119 to $27 751 per quality-adjusted life-year saved, which compares favourably with extending screening to women aged 40-49 years (estimated at between $24 000 and $65 000 per life-year saved). Conclusions: Women 70 years and over, in consultation with their healthcare providers, may want to decide for themselves whether to continue mammographic screening. Decision-support materials are needed for women in this age group.
Resumo:
Objectives To assess the detection rate of congenital fetal malformations and specific problems related to routine ultrasound screening in women with pre-existing diabetes. Methods A retrospective study was carried out to assess the performance of routine ultrasound screening in women with pre-existing diabetes (Types 1 and 2) within a tertiary institution. The incidence, type and risk factors for congenital fetal malformations were determined. The detection rate of fetal anomalies for diabetic women was compared with that for the low-risk population. Factors affecting these detection rates were evaluated. Results During the study period, 12 169 low-risk pregnant women and 130 women with pre-existing diabetes had routine ultrasound screening performed within the institution. A total of 10 major anomalies (7.7%) and three minor anomalies (2.3%) were present in the fetuses of the diabetic women. Central nervous system and cardiovascular system anomalies accounted for 60% of the major anomalies. Peri-conceptional hemoglobin A 1 c of more than 9% was associated with a high prevalence of major anomalies (14311000). Women who had fetuses with major anomalies bad a significantly higher incidence of obesity (78% vs. 37%; P < 0.05). Ultrasound examination of these diabetic pregnancies showed high incidences of suboptimal image quality (37%), incomplete examinations, and repeat examinations (17%). Compared to the 'low-risk' non-diabetic population from the same institution, the relative risk for a major congenital anomaly among the diabetic women was 5.9-fold higher (95% confidence interval, 2.9-11.9). The detection rate for major fetal anomalies was significantly lower for diabetic women (30% vs. 73%; P < 0.01), and the mean body mass index for the diabetic group was significantly higher (29 vs. 23 kg/m(2); P < 0.001). Conclusion The incidence of congenital anomalies is higher in diabetic pregnancies. Unfortunately, the detection rate for fetal anomalies by antenatal ultrasound scan was significantly, worse than that for the low-risk population. This is likely to be related to the maternal body habitus and unsatisfactory examinations. Methods to overcome these difficulties are discussed.
Resumo:
Background/Aims: Concordance of iron indices between same sex siblings homozygous for the cysteine-to-tyrosine substitution at amino acid 282 (C282Y) mutation suggests that the variable phenotype in hereditary hemochromatosis is caused by genetic factors. Concordance of iron indices between same-sex heterozygous sibling pairs would provide further evidence of genetic modifiers of disease expression, and guidance for family screening strategies of subjects heterozygous for the C282Y mutation. Methods: We compared the iron indices of 35 C282Y homozygous and 35 C282Y heterozygous same-sex sibling pairs. To clarify whether concordance between siblings was due to environmental or genetic factors we compared the iron indices of 164 C282Y homozygous-normal, same-sex dizygotic twins. Results: Serum ferritin (r = 0.50, P = 0.003), hepatic iron concentration (r = 0.61, P = 0.025) and hepatic iron index (r = 0.67, P = 0.01) were highly concordant in C282Y homozygotes. Heterozygote siblings were concordant for serum ferritin (r = 0.76, P = 0.0001) and transferrin saturation (r = 0.79, P = 0.0001). Homozygote-normal same-sex dizygotic twins were concordant for serum ferritin (r = 0.62, P = 0.0001) but not for transferrin saturation. Conclusions: Concordance of iron indices exists in C282Y homozygote and heterozygote sibling pairs. Siblings of expressing C282Y heterozygotes require phenotypic assessment. These data provide evidence for modifying genes influencing disease expression in hemochromatosis. (C) 2002 European Association for the Study of the Liver. Published by Elsevier Science B.V. All rights reserved.
Resumo:
Objectives. This study aimed to determine the incidence of abdominal aortic aneurysm (AAA) in a large group of siblings of Australian AAA patients to determine if screening in this group is justified. Methods. 1254 siblings of 400 index AAA patients were identified and offered aortic ultrasound screening. An age and sex matched control group was recruited from patients having abdominal CT scans for non-vascular indications. AAA was defined by an infrarenal aortic diameter of greater than or equal to3 cm or a ratio of the infrarenal to suprarenal aortic diameter of greater than or equal to2.0. A ratio of 1.0-1.5 was considered normal, and a ratio of >1.5 to
Resumo:
Recent population studies have demonstrated an association with the red-hair and fair-skin phenotype with variant alleles of the melanocortin-1 receptor (MC1R) which result in amino acid substitutions within the coding region leading to an altered receptor activity. In particular, Arg151Cys, Arg160Trp and Asp294His were the most commonly associated variants seen in the south-east Queensland population with at least one of these alleles found in 93% of those with red hair. In order to study the individual effects of these variants on melanocyte biology and melanocytic pigmentation, we established a series of human melanocyte strains genotyped for the MC1R receptor which included wild-type consensus, variant heterozygotes, compound heterozygotes and homozygotes for Arg151Cys, Arg160Trp, Val60Leu and Val92Met alleles. These strains ranged from darkly pigmented to amelanotic, with all strains of consensus sequence having dark pigmentation. UV sensitivity was found not to be associated with either MC1R genotype or the level of pigmentation with a range of sensitivities seen across all genotypes. Ultrastructural analysis demonstrated that while consensus strains contained stage IV melanosomes in their terminal dendrites, Arg151Cys and Arg160Trp homozygote strains contained only stage II melanosomes. This was despite being able to show expression of tyrosinase and tyrosinase-related protein-1 markers, although at reduced levels and an ability to convert exogenous 3,4-dihydroxyphenyl-alanine (DOPA) to melanin in these strains.
Resumo:
Background Wide testing of the aldosterone: renin ratio among hypertensive individuals has revealed primary aldosteronism to be common, with most patients normokalaemic. Some investigators, however, have reported aldosterone-producing adenoma to be rare among patients so detected. Objective To test the hypothesis that differences among reported studies in the rate of detection of aldosterone-producing adenoma (as opposed to bilateral adrenal hyperplasia) reflect differences in the procedures used for diagnosis of primary aldosteronism, and the methods used to identify aldosterone-producing adenomas. Methods In the newly established Princess Alexandra Hospital Hypertension Unit (PAHHU), we used procedures developed by Greenslopes Hospital Hypertension Unit (which reports that more than 30% of patients with primary aldosteronism have aldosterone-producing adenomas) to diagnose primary aldosteronism and determine the subtype. All patients with an increased aldosterone: renin ratio (measured after correction for hypokalaemia and while the patient was not receiving interfering medications) underwent fludrocortisone suppression testing to confirm or exclude primary aldosteronism; if they were positive, they underwent genetic testing to exclude glucocorticoid-remediable aldosteronism before adrenal venous sampling was used to differentiate lateralizing from bilateral primary aldosteronism. Results This approach allowed PAHHU to diagnose, within 2 years, 54 patients [only seven (13%) hypokalaemic] with primary aldosteronism. All tested negative for glucocorticoid-remediable aldosteronism. Aldosterone production was lateralized to one adrenal in 15 patients (31%; only six hypokalaemic) and was bilateral in 34 (69%; all normokalaemic) of 49 patients who underwent adrenal venous sampling. Among patients with lateralizing adrenal hyperplasia, computed tomography revealed an ipsilateral mass in only six and a contralateral lesion in one. Fourteen patients underwent unilateral adrenalectomy, which cured the hypertension in seven and improved it in the remainder. In patients with bilateral primary aldlosteronism, hypertension responded to spironolactone (112.5-50 mg/ day) or amiloride (2.5-10 mg/day). Conclusion When performed with careful regard to confounding factors, measurement of the aldosterone: renin ratio in all hypertensive individuals, followed by fludrocortisone suppression testing to confirm or exclude primary aldosteronism and adrenal venous sampling to determine the subtype, can result in the detection of significant numbers of patients with specifically treatable or potentially curable hypertension. (C) 2003 Lippincott Williams Wilkins.
Resumo:
The ability to generate enormous random libraries of DNA probes via split-and-mix synthesis on solid supports is an important biotechnological application of colloids that has not been fully utilized to date. To discriminate between colloid-based DNA probes each colloidal particle must be 'encoded' so it is distinguishable from all other particles. To this end, we have used novel particle synthesis strategies to produce large numbers of optically encoded particle suitable for DNA library synthesis. Multifluorescent particles with unique and reproducible optical signatures (i.e., fluorescence and light-scattering attributes) suitable for high-throughput flow cytometry have been produced. In the spectroscopic study presented here, we investigated the optical characteristics of multi-fluorescent particles that were synthesized by coating silica 'core' particles with up to six different fluorescent dye shells alternated with non-fluorescent silica 'spacer' shells. It was observed that the diameter of the particles increased by up to 20% as a result of the addition of twelve concentric shells and that there was a significant reduction in fluorescence emission intensities from inner shells as an increasing number of shells were deposited.