69 resultados para Alternative fluids. Steam injection. Simulation. IOR. Modeling of reservoirs
Resumo:
The adsorption of simple Lennard-Jones fluids in a carbon slit pore of finite length was studied with Canonical Ensemble (NVT) and Gibbs Ensemble Monte Carlo Simulations (GEMC). The Canonical Ensemble was a collection of cubic simulation boxes in which a finite pore resides, while the Gibbs Ensemble was that of the pore space of the finite pore. Argon was used as a model for Lennard-Jones fluids, while the adsorbent was modelled as a finite carbon slit pore whose two walls were composed of three graphene layers with carbon atoms arranged in a hexagonal pattern. The Lennard-Jones (LJ) 12-6 potential model was used to compute the interaction energy between two fluid particles, and also between a fluid particle and a carbon atom. Argon adsorption isotherms were obtained at 87.3 K for pore widths of 1.0, 1.5 and 2.0 nm using both Canonical and Gibbs Ensembles. These results were compared with isotherms obtained with corresponding infinite pores using Grand Canonical Ensembles. The effects of the number of cycles necessary to reach equilibrium, the initial allocation of particles, the displacement step and the simulation box size were particularly investigated in the Monte Carlo simulation with Canonical Ensembles. Of these parameters, the displacement step had the most significant effect on the performance of the Monte Carlo simulation. The simulation box size was also important, especially at low pressures at which the size must be sufficiently large to have a statistically acceptable number of particles in the bulk phase. Finally, it was found that the Canonical Ensemble and the Gibbs Ensemble both yielded the same isotherm (within statistical error); however, the computation time for GEMC was shorter than that for canonical ensemble simulation. However, the latter method described the proper interface between the reservoir and the adsorbed phase (and hence the meniscus).
Resumo:
A Monte Carlo simulation method is Used 10 study the effects of adsorption strength and topology of sites on adsorption of simple Lennard-Jones fluids in a carbon slit pore of finite length. Argon is used as a model adsorbate, while the adsorbent is modeled as a finite carbon slit pore whose two walls composed of three graphene layers with carbon atoms arranged in a hexagonal pattern. Impurities having well depth of interaction greater than that of carbon atom are assumed to be grafted onto the surface. Different topologies of the impurities; corner, centre, shelf and random topologies are studied. Adsorption isotherms of argon at 87.3 K are obtained for pore having widths of 1, 1.5 and 3 11111 using a Grand Canonical Monte Carlo simulation (GCMC). These results are compared with isotherms obtained for infinite pores. It is shown that the Surface heterogeneity affects significantly the overall adsorption isotherm, particularly the phase transition. Basically it shifts the onset of adsorption to lower pressure and the adsorption isotherms for these four impurity models are generally greater than that for finite pore. The positions of impurities on solid Surface also affect the shape of the adsorption isotherm and the phase transition. We have found that the impurities allocated at the centre of pore walls provide the greatest isotherm at low pressures. However when the pressure increases the impurities allocated along the edges of the graphene layers show the most significant effect on the adsorption isotherm. We have investigated the effect of surface heterogeneity on adsorption hysteresis loops of three models of impurity topology, it shows that the adsorption branches of these isotherms are different, while the desorption branches are quite close to each other. This suggests that the desorption branch is either the thermodynamic equilibrium branch or closer to it than the adsorption branch. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
A new model proposed for the gasification of chars and carbons incorporates features of the turbostratic nanoscale structure that exists in such materials. The model also considers the effect of initial surface chemistry and different reactivities perpendicular to the edges and to the faces of the underlying crystallite planes comprising the turbostratic structure. It may be more realistic than earlier models based on pore or grain structure idealizations when the carbon contains large amounts of crystallite matter. Shrinkage of the carbon particles in the chemically controlled regime is also possible due to the random complete gasification of crystallitic planes. This mechanism can explain observations in the literature of particle size reduction. Based on the model predictions, both initial surface chemistry and the number of stacked planes in the crystallites strongly influence the reactivity and particle shrinkage. Its test results agree well with literature data on the air-oxidation of Spherocarb and show that it accurately predicts the variation of particle size with conversion. Model parameters are determined entirely from rate measurements.
Resumo:
A comprehensive probabilistic model for simulating dendrite morphology and investigating dendritic growth kinetics during solidification has been developed, based on a modified Cellular Automaton (mCA) for microscopic modeling of nucleation, growth of crystals and solute diffusion. The mCA model numerically calculated solute redistribution both in the solid and liquid phases, the curvature of dendrite tips and the growth anisotropy. This modeling takes account of thermal, curvature and solute diffusion effects. Therefore, it can simulate microstructure formation both on the scale of the dendrite tip length. This model was then applied for simulating dendritic solidification of an Al-7%Si alloy. Both directional and equiaxed dendritic growth has been performed to investigate the growth anisotropy and cooling rate on dendrite morphology. Furthermore, the competitive growth and selection of dendritic crystals have also investigated.
Resumo:
NPT and NVT Monte Carlo simulations are applied to models for methane and water to predict the PVT behaviour of these fluids over a wide range of temperatures and pressures. The potential models examined in this paper have previously been presented in the literature with their specific parameters optimised to fit phase coexistence data. The exponential-6 potential for methane gives generally good prediction of PVT behaviour over the full range of temperature and pressures studied with the only significant deviation from experimental data seen at high temperatures and pressures. The NSPCE water model shows very poor prediction of PVT behaviour, particularly at dense conditions. To improve this. the charge separation in the NSPCE model is varied with density. Improvements for vapour and liquid phase PVT predictions are achieved with this variation. No improvement was found in the prediction of the oxygen-oxygen radial distribution by varying charge separation under dense phase conditions. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Discrete element method (DEM) modeling is used in parallel with a model for coalescence of deformable surface wet granules. This produces a method capable of predicting both collision rates and coalescence efficiencies for use in derivation of an overall coalescence kernel. These coalescence kernels can then be used in computationally efficient meso-scale models such as population balance equation (PBE) models. A soft-sphere DEM model using periodic boundary conditions and a unique boxing scheme was utilized to simulate particle flow inside a high-shear mixer. Analysis of the simulation results provided collision frequency, aggregation frequency, kinetic energy, coalescence efficiency and compaction rates for the granulation process. This information can be used to bridge the gap in multi-scale modeling of granulation processes between the micro-scale DEM/coalescence modeling approach and a meso-scale PBE modeling approach.
Resumo:
Adsorption of binary hydrocarbon mixtures involving methane in carbon slit pores is theoretically studied here from the viewpoints of separation and of the effect of impurities on methane storage. It is seen that even small amounts of ethane, propane, or butane can significantly reduce the methane capacity of carbons. Optimal pore sizes and pressures, depending on impurity concentration, are noted in the present work, suggesting that careful adsorbent and process design can lead to enhanced separation. These results are consistent with earlier literature studies for the infinite dilution limit. For methane storage applications a carbon micropore width of 11.4 Angstrom (based on distance between centers of carbon atoms on opposing walls) is found to be the most suitable from the point of view of lower impurity uptake during high-pressure adsorption and greater impurity retention during low-pressure delivery. The results also theoretically confirm unusual recently reported observations of enhanced methane adsorption in the presence of a small amount of heavier hydrocarbon impurity.
Resumo:
Engineering This investigation examined the rheological (viscosity and yield stress) and material property (density) characteristics of the thickened meal-time and videofluorscopy fluids provided by 10 major metropolitan hospitals. Differences in the thickness of thickened fluids were considered as a source of variability and potential hazard for inter-hospital transfers of dysphagic patients. The results indicated considerable differences in the viscosity, density, and yield stress of both meal-time and videofluoroscopy fluids. In theory, the results suggest that dysphagic patients transferred between hospitals could be placed on inappropriate levels of fluid thickness because of inherent differences in the rheology and material property characteristics of the fluids provided by different hospitals. Slowed improvement or medical complications are potential worst-case scenarios for dysphagic patients if the difference between the thick fluids offered by 2 hospitals are extreme. The investigation outlines the most appropriate way to assess the rheological and material property characteristics of thickened fluids. In addition, it suggests a plan of quality improvement to reduce the variability of the thickness of fluids offered at different hospitals.
Resumo:
Objective rheological assessment of fluids given to dysphagic patients at mealtime and during videofluoroscopy was carried out using a multicenter format. Thin, quarter-thick, half-thick and full-thick fluids were examined for the degree of correlation between mealtime fluids and their allegedly matched videofluoroscopy counterparts. The study was carried out to determine whether perceived subjective differences between mealtime fluids and videofluoroscopy fluids could be quantified using the rheological parameters of viscosity, density, and yield stress. The results showed poor correlation between mealtime fluids and videofluoroscopy fluids over all parameters. In general, the videofluoroscopy fluids were more viscous, more dense, and showed higher yield stress values than their mealtime counterparts. Given these results, it is reasonable to assume that the fluids used during videofluoroscopy do not provide an accurate indication of swallowing ability at mealtime. Therefore, it is suggested that clinicians use objective methods to theologically match videofluoroscopy fluids to mealtime fluids.