53 resultados para portable instruments
Resumo:
A method is presented for including path propagation effects into models of radiofrequency resonators for use in magnetic resonance imaging. The method is based on the use of Helmholtz retarded potentials and extends our previous work on current density models of resonators based on novel inverse finite Hilbert transform solutions to the requisite integral equations. Radiofrequency phase retardation effects are most pronounced at high field strengths (frequencies) as are static field perturbations due to the magnetic materials in the resonators themselves. Both of these effects are investigated and a novel resonator structure presented for use in magnetic resonance microscopy.
Resumo:
The aim of the present research was to provide school psychologists with valid instruments with which to assess the goals and reputations of young children. This was achieved by ascertaining whether the factor structures and the second-order factor models of the high school versions of the Importance of Goals (Carroll, et al., 1997) and Reputation Enhancement Scales (Carroll, et al., 1999) could be replicated with a primary school sample. Eight hundred and eighty-six 10 to 12 year old children were administered modified versions of the two scales, which were combined and renamed the Children's Activity Questionnaire. For the two scales, the factor structure proved replicable and reliable with the primary school sample. A comparison between the factor loadings of the primary school and the high school samples using the coefficient of congruence procedure demonstrated similarity indicating that the scales are replicable and able to be used with a younger primary school sample. Structural equation modelling indicated that the second-order factor structure of the Importance of Goals Scale was acceptable but this was not the case for the second-order factor structure of the Reputation Enhancement Scale.
Resumo:
In this article we report on progress in high magnetic field MRI at the University of Florida in support of our new 750MHz wide bore and 11.7T/40cm MR instruments. The primary emphasis is on the associated rf technology required, particularly high frequency volume and phased array coils. Preliminary imaging results at 750MHz are presented. Our results imply that the pursuit of even higher fields seems warranted. (C) 2002 Elsevier Science B.V. All rights reserved.
The polar ionosphere at Zhongshan Station on May 11, 1999, the day the solar wind almost disappeared
Resumo:
The solar wind almost disappeared on May 11,1999: the solar wind plasma density and' dynamic pressure were less than 1 cm(-3) and 0.1 nPa respectively, while the interplanetary magnetic field was northward. The polar ionospheric data observed by the multi-instruments at Zhongshan Station in Antarctica on such special event day was compared with those of the control day (May 14). It was shown that geomagnetic activity was very quiet on May 11 at Zhongshan. The magnetic pulsation, which usually occurred at about magnetic noon, did not appear. The ionosphere was steady and stratified, and the F-2 layer spread very little. The critical frequency of dayside F-2 layer, f(0)F(2), was larger than that of control day, and the peak of f(0)F(2) appeared 2 hours earlier. The ionospheric drift velocity was less than usual. There were intensive auroral E-s appearing at magnetic noon. All this indicates that the polar ionosphere was extremely quiet and geomagnetic field was much more dipolar on May 11. There were some signatures of auroral substorm before midnight, such as the negative deviation of the geomagnetic H component, accompanied with auroral E-s and weak Pc3 pulsation.
Resumo:
Assessment has been integral to career counseling since the early 1900s. During that time, the greatest amount of attention was focused on quantitative assessment. Thus, there is still very little to guide the development and conduct of qualitative assessment in career counseling. The authors present an overview of qualitative career assessment and its theoretical underpinnings and propose suggestions that could guide the development of qualitative career assessment instruments.
Resumo:
Background: The purpose of the present paper was to investigate whether screening for abdominal aortic aneurysm (AAA) causes health-related quality of life to change in men or their partners. Methods: A cross-sectional case-control comparison was undertaken of men aged 65-83 years living in Perth, Western Australia, using questionnaires incorporating three validated instruments (Medical Outcomes Study Short Form-36, EuroQol EQ-5D and Hospital Anxiety and Depression Scale) as well as several independent questions about quality of life. The 2009 men who attended for ultrasound scans of the abdominal aorta completed a short prescreening questionnaire about their perception of their general health. Four hundred and ninety-eight men (157 with an AAA and 341 with a normal aorta) were sent two questionnaires for completion 12 months after screening, one for themselves and one for their partner, each being about the quality of life of the respondent. Results: Men with an AAA were more limited in performing physical activities than those with a normal aorta (t-test of means P = 0.04). After screening, men with an AAA were significantly less likely to have current pain or discomfort than those with a normal aorta (multivariate odds ratio: 0.5; 95% confidence interval (Cl): 0.3-0.9) and reported fewer visits to their doctor. The mean level of self-perceived general health increased for all men from before to after screening (from 63.4 to 65.4). Conclusions: Apart from physical functioning, screening was not associated with decreases in health and well-being. A high proportion of men rated their health over the year after screening as being either the same or improved, regardless of whether or not they were found to have an AAA.
Resumo:
This paper reports an investigation on techniques for determining elastic modulus and intrinsic stress gradient in plasma-enhanced chemical vapor deposition (PECVD) silicon nitride thin films. The elastic property of the silicon nitride thin films was determined using the nanoindentation method on silicon nitride/silicon bilayer systems. A simple empirical formula was developed to deconvolute the film elastic modulus. The intrinsic stress gradient in the films was determined by using micrometric cantilever beams, cross-membrane structures and mechanical simulation. The deflections of the silicon nitride thin film cantilever beams and cross-membranes caused by in-thickness stress gradients were measured using optical interference microscopy. Finite-element beam models were built to compute the deflection induced by the stress gradient. Matching the deflection computed under a given gradient with that measured experimentally on fabricated samples allows the stress gradient of the PECVD silicon nitride thin films introduced from the fabrication process to be evaluated.
Resumo:
This paper reports a parametric investigation and development of grinding technologies for micro aspherical mould inserts using parallel grinding method. The parametric investigation revealed that at nanometric scale the undeformed chip thickness has little influence on the surface finish of ground inserts. The grinding trace spacing has a slightly larger influence on the surface finish. A new technique was developed to true and dress the resin bonded micro wheels with mesh size of #3000, which produced a satisfactory wheel form accuracy and relatively high grain packing density. A form error compensation technique was also developed, with which mould inserts of submicron form accuracy were consistently produced. Using the developed technologies, micro aspherical inserts of diameters ranging from 200 mu m to 1000 mu m with surface finish of around 10 nm and form error of similar to 0.2-0.4 mu m were successfully fabricated. (c) 2005 Elsevier Inc. All rights reserved.