77 resultados para Plackett-burman designs
Resumo:
Magnetic resonance microscopy (MRM) depends on the use of high field, superconducting magnet systems for its operation. The magnets that are conventionally used are those that were initially designed for chemical structural analysis work. A novel, compact magnet designed specifically for MRM is presented here, and while preserving high field, high homogeneity conditions, has a length less than one-third that of conventional systems. This enables much better access to samples, an important consideration in many MRM experiments. As the homogeneity of a magnet is strongly dependent on its length, novel geometries and optimization techniques are required to meet the requirements of MRM in a compact system. An important outcome of the stochastic optimization performed in this work, is that the use used of a thin superconducting solenoid surrounded by counterwound disk windings provides a mechanism for drastic length reductions over conventional magnet designs. (C) 1998 American Institute of Physics.
Resumo:
A novel three-axis gradient set and RF resonator for orthopedic MRT has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an are of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 mu s, conforming closely with theoretical predictions. Preliminary images from the set are presented. (C) 1999 Academic Press.
Resumo:
This paper describes a hybrid numerical method for the design of asymmetric magnetic resonance imaging magnet systems. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. A new type of asymmetric magnet is proposed in this work. The asymmetric MRI magnet allows the diameter spherical imaging volume to be positioned close to one end of the magnet. The main advantages of making the magnet asymmetric include the potential to reduce the perception of claustrophobia for the patient, better access to the patient by attending physicians, and the potential for reduced peripheral nerve stimulation due to the gradient coil configuration. The results highlight that the method can be used to obtain an asymmetric MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1.2 m in length. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 1999 Academic Press.
Resumo:
This paper describes a hybrid numerical method of an inverse approach to the design of compact magnetic resonance imaging magnets. The problem is formulated as a field synthesis and the desired current density on the surface of a cylinder is first calculated by solving a Fredholm equation of the first, kind. Nonlinear optimization methods are then invoked to fit practical magnet coils to the desired current density. The field calculations are performed using a semi-analytical method. The emphasis of this work is on the optimal design of short MRI magnets. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric MRI magnets as well as asymmetric magnets. The results highlight that the method can be used to obtain a compact MRI magnet structure and a very homogeneous magnetic field over the central imaging volume in clinical systems of approximately 1 m in length, significantly shorter than current designs. Viable asymmetric magnet designs, in which the edge of the homogeneous region is very close to one end of the magnet system are also presented. Unshielded designs are the focus of this work. This method is flexible and may be applied to magnets of other geometries. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00303-5].
Resumo:
The fine structure of a directed triple system of index lambda is the vector (c(1), c(2),...,C-lambda), where c(i) is the number of directed triples appearing precisely i times in the system. We determine necessary and sufficient conditions for a vector to be the fine structure of a directed triple system of index 3 for upsilon = 2 (mod 3).
Resumo:
In this paper, the minimum-order stable recursive filter design problem is proposed and investigated. This problem is playing an important role in pipeline implementation sin signal processing. Here, the existence of a high-order stable recursive filter is proved theoretically, in which the upper bound for the highest order of stable filters is given. Then the minimum-order stable linear predictor is obtained via solving an optimization problem. In this paper, the popular genetic algorithm approach is adopted since it is a heuristic probabilistic optimization technique and has been widely used in engineering designs. Finally, an illustrative example is sued to show the effectiveness of the proposed algorithm.
Resumo:
The compound eyes of mantis shrimps, a group of tropical marine crustaceans, incorporate principles of serial and parallel processing of visual information that may be applicable to artificial imaging systems. Their eyes include numerous specializations for analysis of the spectral and polarizational properties of light, and include more photoreceptor classes for analysis of ultraviolet light, color, and polarization than occur in any other known visual system. This is possible because receptors in different regions of the eye are anatomically diverse and incorporate unusual structural features, such as spectral filters, not seen in other compound eyes. Unlike eyes of most other animals, eyes of mantis shrimps must move to acquire some types of visual information and to integrate color and polarization with spatial vision. Information leaving the retina appears to be processed into numerous parallel data streams leading into the central nervous system, greatly reducing the analytical requirements at higher levels. Many of these unusual features of mantis shrimp vision may inspire new sensor designs for machine vision
Resumo:
With the advent of functional neuroimaging techniques, in particular functional magnetic resonance imaging (fMRI), we have gained greater insight into the neural correlates of visuospatial function. However, it may not always be easy to identify the cerebral regions most specifically associated with performance on a given task. One approach is to examine the quantitative relationships between regional activation and behavioral performance measures. In the present study, we investigated the functional neuroanatomy of two different visuospatial processing tasks, judgement of line orientation and mental rotation. Twenty-four normal participants were scanned with fMRI using blocked periodic designs for experimental task presentation. Accuracy and reaction time (RT) to each trial of both activation and baseline conditions in each experiment was recorded. Both experiments activated dorsal and ventral visual cortical areas as well as dorsolateral prefrontal cortex. More regionally specific associations with task performance were identified by estimating the association between (sinusoidal) power of functional response and mean RT to the activation condition; a permutation test based on spatial statistics was used for inference. There was significant behavioral-physiological association in right ventral extrastriate cortex for the line orientation task and in bilateral (predominantly right) superior parietal lobule for the mental rotation task. Comparable associations were not found between power of response and RT to the baseline conditions of the tasks. These data suggest that one region in a neurocognitive network may be most strongly associated with behavioral performance and this may be regarded as the computationally least efficient or rate-limiting node of the network.
Resumo:
A rapid spherical harmonic calculation method is used for the design of Nuclear Magnetic Resonance shim coils. The aim is to design each shim such that it generates a field described purely by a single spherical harmonic. By applying simulated annealing techniques, coil arrangements are produced through the optimal positioning of current-carrying circular arc conductors of rectangular cross-section. This involves minimizing the undesirable harmonies in relation to a target harmonic. The design method is flexible enough to be applied for the production of coil arrangements that generate fields consisting significantly of either zonal or tesseral harmonics. Results are presented for several coil designs which generate tesseral harmonics of degree one.
Resumo:
In this paper we propose a new framework for evaluating designs based on work domain analysis, the first phase of cognitive work analysis. We develop a rationale for a new approach to evaluation by describing the unique characteristics of complex systems and by showing that systems engineering techniques only partially accommodate these characteristics. We then present work domain analysis as a complementary framework for evaluation. We explain this technique by example by showing how the Australian Defence Force used work domain analysis to evaluate design proposals for a new system called Airborne Early Warning and Control. This case study also demonstrates that work domain analysis is a useful and feasible approach that complements standard techniques for evaluation and that promotes a central role for human factors professionals early in the system design and development process. Actual or potential applications of this research include the evaluation of designs for complex systems.
Resumo:
Studies were conducted at sites in south-cast Queensland, Australia, to investigate the effect of habitat modification for mosquito control on the distribution of eggshells of the salt marsh mosquito, Ochlerotatus vigilax (Skuse). Modifications were mainly tunnelling, but an Open Marsh Water Management (OMWM) site and a grid-ditched site were also included. There were two separate experimental designs: one was data collected Before and After (BA) modification and the other was for other sites with a Treatment and Control (TC) experimental design. For the BA data, there were significant reductions in eggshells after modification. Eggshells were generally fewer after modification in areas which were close to unrestricted tidal flushing. A sandy substrate and vegetation changes which resulted in reduced Sporobolus virginicus or mixed Sporobolus and Sarcocornia quinqueflora also contributed to the effect. In the TC experiment, there was no effect of modification at the tunnelled site, eggshells were fewer at the OMWM site, but there were more eggshells at the grid-ditched site. There was some general indication that recent oviposition activity was reduced in sites that had been modified, evidenced by a relatively small proportion of young (dark coloured) eggshells.
Resumo:
Objective To determine the accuracy of the whispered voice test in detecting hearing impairment in adults and children. Design Systematic review of studies of test accuracy. Data sources Medline, Embase, Science Citation Index, unpublished theses, manual searching of bibliographies of known primary and review articles, and contact with authors. Study selection Two reviewers independently selected and extracted data on study characteristics, quality, and accuracy of studies. Studies were included if they had cross sectional designs, at least one of the index tests was the whispered voice test, and the reference test (audiometry) was performed on at least 80% of the participants. Data extraction Data were used to form 2x2 contingency tables with hearing impairment by audiometry as the reference standard. Data synthesis The eight studies that were found used six different techniques. The sensitivity in the four adult studies was 90% or 100% and the specificity was 70% to 87%. The sensitivity in the four childhood studies ranged from 80% to 96% and specificity ranged from 90% to 98%. Conclusion The whispered voice test is a simple and accurate test for detecting hearing impairment. There is some concern regarding the lower sensitivity in children and the overall reproducibility of the test, particularly in primary care settings. Further studies should be conducted in primary care settings to explore the influence of components of the testing procedure to optimise test sensitivity and to promote standardisation of the testing procedure.
Resumo:
We used an event related fMRI design to study the BOLD response in Huntington’s disease (HD) patients during performance of a Simon interference task. We hypothesised that HD patients will demonstrate significantly slower RTs than controls, and that there will be significant differences in the pattern of brain activation between groups. Seventeen HD patients and 15 age and sex matched controls were scanned using 3T GE scanner (FOV = 24 cm2; TE = 40 ms; TR = 3 s; FA = 60°; slice thickness = 6 mm; in-plane resolution = 1.88x1.88 mm2). The task involved two activation conditions, namely congruent (for example, left pointing arrow appearing on the left side of the screen) and incongruent (for example, left pointing arrow appearing on the right side of the screen), and a baseline condition. Each stimulus was presented for 2500 ms followed by a blank screen for 500 ms. Subjects were instructed to press a button using the same hand as indicated by the direction of the arrow head and were given 3000 ms to respond. Data analysis was performed using SPM2 with a random effects analysis model. For each subject parameter estimates for combined task conditions (congruent and incongruent combined) were calculated. Comparisons such as these, based on block designs, have superior statistical power for detecting subtle changes in the BOLD response anywhere in the brain. The activations reported are significant at PFDR_corr
Resumo:
Vertical direct chill (VDC) casting of aluminium alloys is a mature process that has evolved over many decades through gradual change to both equipment design and casting practice. Today, air-pressurised, continuous lubrication, hot top mould systems with advanced station automation are selected as the process of choice for producing extrusion billet. Specific sets of operating parameters are employed on these stations for each alloy and size combination to produce optimal billet quality. The designs and parameters are largely derived from past experience and accumulated know-how. Recent experimental work at the University of Queensland has concentrated on understanding the way in which the surface properties of liquid aluminium alloys, e.g., surface tension, wetting angle and oxide skin strength, influence the size and shape of the naturally-stab le meniscus for a given alloy, temperature and atmosphere. The wide range of alloy-and condition-dependent values measured has led to the consideration of how these properties impact the stability of the enforced molten metal meniscus within the hot top mould cavity. The actual shape and position of the enforced meniscus is controlled by parameters such as the upstream conduction distance (UCD) from sub-mould cooling and the molten metal head. The degree of deviation of this actual meniscus from the predicted stable meniscus is considered to be a key driver in surface defect formation. This paper reports on liquid alloy property results and proposes how this knowledge might be used to better design VDC mould systems and casting practices.
Resumo:
Studies of alcoholism etiology often focus on genetic or psy-chosocial approaches, but not both. Greater understanding of the etiology of alcohol, tobacco and other addictions will come from integration of these research traditions. A research approach is outlined to test three models for the etiology of addictions — behavioral undercontrol, pharmacologic vulnerability, negative affect regulation — addressing key questions including (i) mediators of genetic effects, (ii) genotype-environment correlation effects, (iii) genotype x environment interaction effects, (iv) the developmental unfolding of genetic and environmental effects, (v) subtyping including identification of distinct trajectories of substance involvement, (vi) identification of individual genes that contribute to risk, and (vii) the consequences of excessive use. By using coordinated research designs, including prospective assessment of adolescent twins and their siblings and parents; of adult substance dependent and control twins and their MZ and DZ cotwins, the spouses of these pairs, and their adolescent offspring; and of regular families; by selecting for gene-mapping approaches sibships screened for extreme concordance or discordance on quantitative indices of substance use; and by using experimental (drug challenge) as well as survey approaches, a number of key questions concerning addiction etiology can be addressed. We discuss complementary strengths and weaknesses of different sampling strategies, as well as methods to implement such an integrated approach illustrated for the study of alcoholism etiology. A coordinated program of twin and family studies will allow a comprehensive dissection of the interplay of genetic and environmental risk-factors in the etiology of alcoholism and other addictions.