88 resultados para Input impedance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-frequency bio-impedance has the potential to identify infants at risk of poor neurodevelopmental outcome following hypoxia by detecting cerebral edema. This study investigated the relationship between the severity of an hypoxic/ischemic episode, neurological outcome following the hypoxia and non-invasively measured cerebral bioelectrical impedance in piglets. One-day-old piglets were anaesthetised and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 3-5%. Severe hypoxia was defined as hypoxia resulting in at least 30 min of low amplitude EEG (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerebral electrical impedance is useful for the detection of cerebral edema following hypoxia in newborn infants. Thus it may be useful for determining neurological outcome or monitoring treatment. Hypothermia is a promising new therapy currently undergoing trials, but will alter impedance measurements. This study aimed to define the relationship between temperature and both cerebral and whole body electrical impedance, and to derive correction factors for adjustment of impedance measurements during hypothermia. In eight anaesthetized 1-2 day old piglets rectal, tympanic and scalp temperatures were monitored continuously. Following baseline readings at a rectal temperature of 39degreesC, piglets were cooled to 32degreesC. Four piglets were re-warmed. Cerebral and whole body impedance were measured at each 0.5degreesC as rectal temperature decreased. There was a strong linear relationship between both cerebral and whole body impedance and each of the temperatures measured. There was no difference in the relationship between impedance and rectal, tympanic or scalp temperatures. The relationship for impedance and rectal temperature was the same during cooling and re-warming. Using the correction factors derived it will be possible to accurately monitor cerebral and whole body fluid distribution during hypothermic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acquisition by Processing Theory (APT) is a unified account of language processing and learning that encompasses both L1 and L2 acquisition. Bold in aim and broad in scope, the proposal offers parsimony and comprehensiveness, both highly desirable in a theory of language acquisition. However, the sweep of the proposal is accompanied by an economy of description that makes it difficult to evaluate the validity of key learning claims, or even how literally they are to be interpreted. Two in particular deserve comment; the first concerns the learning mechanisms responsible for adding new L2 grammatical information, and the second the theoretical and empirical status of the activation concept used in the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper re-examines the stability of multi-input multi-output (MIMO) control systems designed using sequential MIMO quantitative feedback theory (QFT). In order to establish the results, recursive design equations for the SISO equivalent plants employed in a sequential MIMO QFT design are established. The equations apply to sequential MIMO QFT designs in both the direct plant domain, which employs the elements of plant in the design, and the inverse plant domain, which employs the elements of the plant inverse in the design. Stability theorems that employ necessary and sufficient conditions for robust closed-loop internal stability are developed for sequential MIMO QFT designs in both domains. The theorems and design equations facilitate less conservative designs and improved design transparency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detailed analysis of body composition in children has helped to understand changes that occur in growth and disease. Bioelectrical impedance analysis (BIA) has gained popularity as a simple, non-invasive and inexpensive tool of body composition assessment. Being an indirect technique, prediction equations have to be used in the assessment of body composition. There are many prediction equations available in the literature for the assessment of body composition from BIA. This study aims to cross-validate some of those prediction equations to determine the suitability of their use on Australian children of white Caucasian and Sri Lankan origins. Height, weight and BIA were measured. Total body water was measured using the isotope dilution method (D2O). Fat-mass (FM) and %FM were estimated from BIA using ten prediction equations described in the literature. Five to 14.99-year-old healthy, 96 white Caucasians and 42 Sri Lankan children were studied. The equation of Schaefer et al was the most suitable prediction equation for this group with the lowest mean bias for %FM assessment in both Caucasian (–1.0±9.6%) and Sri Lankan (1.6±5.2%) children and the fat content of the individuals did not influence the predictions by this equation. Impedance index (height2/impedance) explained for 80% of TBW in white Caucasians and 93% in Sri Lankans and figures were similar for the prediction of FFM. We conclude that BIA can be used effectively in the assessment of body composition in children. However, for the assessment of body composition using BIA, either prediction equations should be derived to suit the local populations or existing equations should be cross-validated to determine their suitability before their application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, nonlinear curve fitting. An alternative fitting method is described that uses only the magnitude of the measured impedances at four selected frequencies. The two methods showed excellent agreement when compared using data obtained both from measurements of equivalent circuits and of humans. These results suggest that operational equivalence to a technically complex, frequency-scanning, phase-sensitive BIS analyser could be achieved from a simple four-frequency, impedance-only analyser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new mutual impedance - the receiving mutual impedance - between two normal-mode helical antennas is defined, measured, and theoretically calculated. The variations of the receiving mutual impedance with antenna separation, with frequency, and with excitation source direction are critically investigated. An application of the receiving mutual impedance in direction finding demonstrates its more accurate description of the mutual coupling effect than that using the conventional mutual impedance.