58 resultados para INSTRUMENTATION TECHNIQUES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most sugarcane breeding programs in Australia use large unreplicated trials to evaluate clones in the early stages of selection. Commercial varieties that are replicated provide a method of local control of soil fertility. Although such methods may be useful in detecting broad trends in the field, variation often occurs on a much smaller scale. Methods such as spatial analysis adjust a plot for variability by using information from immediate neighbours. These techniques are routinely used to analyse cereal data in Australia and have resulted in increased accuracy and precision in the estimates of variety effects. In this paper, spatial analyses in which the variability is decomposed into local, natural, and extraneous components are applied to early selection trials in sugarcane. Interplot competition in cane yield and trend in sugar content were substantial in many of the trials and there were often large differences in the selections between the spatial and current method used by the Bureau of Sugar Experiment Stations. A joint modelling approach for tonnes sugar per hectare in response to fertility trends and interplot competition is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microbiological quality of routinely processed tripe and rumen pillars were compared with those derived after emptying the rumen (paunch) without using water (dry dumping) and after deliberately bursting the paunches before processing. Prior to packing the mean:log(10) aerobic plate counts (APC) for the routinely processed tripe and rumen pillars were 3.55+/-1.08 and 3.28+/-0.87/g respectively. The corresponding mean log(10) total coliform counts (TCC) were 1.27+/-1.28 and 2.08+/-0.87. The mean log(10) APC counts on tripe and rumen pillars after dry-dumping were 3.06+/-0.60 and 3.90+/-0.75/g, respectively. The corresponding mean log(10) TCC were 1.03+/-0.60/g and 2.75+/-1.14/g respectively. After deliberately bursting the paunches, before processing, the mean log(10) APC counts on tripe and rumen pillars were 3.55+/-0.83/g and 3.50+/-0.59/g and the mean log(10) TCC were 1.54+/-0.95/g and 2.66+/-0.82/g respectively. In all cases the prevalence of Salmonella and Campylobacter spp. was less than 3%. The results indicate that both tripe and rumen pillars can be produced after dry dumping without compromising the quality of tripe and rumen pillars. Similarly, incidentally burst paunches that become contaminated with ingesta on the serosal surface can be processed without compromising product quality. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of permanently attaching piezoelectric transducers to structural surfaces has demonstrated great potential for quantitative non-destructive evaluation and smart materials design. For thin structural members such as composite laminated plates, it has been well recognized that guided Lamb wave techniques can provide a very sensitive and effective means for large area interrogation. However, since in these applications multiple wave modes are generally generated and the individual modes are usually dispersive, the received signals are very complex and difficult to interpret. An attractive way to deal with this problem has recently been introduced by applying piezoceramic transducer arrays or interdigital transducer (IDT) technologies. In this paper, the acoustic wave field in composite laminated plates excited by piezoceramic transducer arrays or IDT is investigated. Based on dynamic piezoelectricity theory, a discrete layer theory and a multiple integral transform method, an analytical-numerical approach is developed to evaluate the input impedance characteristics of the transducer and the surface velocity response of the plate. The method enables the quantitative evaluation of the influence of the electrical characteristics of the excitation circuit, the geometric and piezoelectric properties of the transducer array, and the mechanical and geometrical features of the laminate. Numerical results are presented to validate the developed method and show the ability of single wave mode selection and isolation. The results show that the interaction between individual elements of the piezoelectric array has a significant influence on the performance of the IDT, and these effects can not be neglected even in the case of low frequency excitation. It is also demonstrated that adding backing materials to the transducer elements can be used to improve the excitability of specific wave modes. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chest clapping, vibration, and shaking were studied in 10 physiotherapists who applied these techniques on an anesthetized animal model. Hemodynamic variables (such as heart rate, blood pressure, pulmonary artery pressure, and right atrial pressure) were measured during the application of these techniques to verify claims of adverse events. In addition, expired tidal volume and peak expiratory flow rate were measured to ascertain effects of these techniques. Physiotherapists in this study applied chest clapping at a rate of 6.2 +/- 0.9 Hz, vibration at 10.5 +/- 2.3 Hz, and shaking at 6.2 +/- 2.3 Hz. With the use of these rates, esophageal pressure swings of 8.8 +/- 5.0, 0.7 +/- 0.3, and 1.4 +/- 0.7 mmHg resulted from clapping, vibration, and shaking respectively. Variability in rates and forces generated by these techniques was 80% of variance in shaking force (P = 0.003). Application of these techniques by physiotherapists was found to have no significant effects on hemodynamic and most ventilatory variables in this study. From this study, we conclude that chest clapping, vibration, and shaking 1) can be consistently performed by physiotherapists; 2) are significantly related to physiotherapists' characteristics, particularly clinical experience; and 3) caused no significant hemodynamic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The left ventricular response to dobutamine may be quantified using tissue Doppler measurement of myocardial velocity or displacement or 3-dimensional echocardiography to measure ventricular volume and ejection fraction. This study sought to explore the accuracy of these methods for predicting segmental and global responses to therapy. Standard dobutamine and 3-dimensional echocardiography were performed in 92 consecutive patients with abnormal left ventricular function at rest. Recovery of function was defined by comparison with follow-up echocardiography at rest 5 months later. Segments that showed improved regional function at follow-up showed a higher increment in peak tissue Doppler velocity with dobutamine therapy than in nonviable segments (1.2 +/- 0.4 vs 0.3 +/- 0.2 cm/s, p = 0.001). Similarly, patients who showed a > 5% improvement of ejection fraction at follow-up showed a greater displacement response to dobutamine (6.9 +/- 3.2 vs 2.1 +/- 2.3 mm, p = 0.001), as well as a higher rate of ejection fraction, response to dobutamine (9 +/- 3% vs 2 +/- 2%, p = 0.001). The optimal cutoff values for predicting subsequent recovery of function at rest were an increment of peak velocity > 1 cm/s, >5 mm of displacement, and a >5% improvement of ejection fraction with low-dose dobutamine. (C) 2003 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The health benefits provided by probiotic bacteria have led to their increasing use in fermented and other dairy products. However, their viability in these products is low. Encapsulation has been investigated to protect the bacteria in the product's environment and improve their survival. There are two common encapsulation techniques, namely extrusion and emulsion, to encapsulate the probiotics for their use in the fermented and other dairy products. This review evaluates the merits and limitations of these two techniques, and also discusses the supporting materials and special treatments used in encapsulation processes. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equipment used to measure magnetic fields and, electric currents in residences is described. The instrumentation consisted of current transformers, magnetic field probes and locally designed and, built signal conditioning modules. The data acquisition system was capable of unattended recording for extended time periods. The complete system was calibrated to verify its response to known physical inputs. (C) 2003 ISA-The Instrumentation Automation Society.